Safety and Efficacy of the Combo Bio-engineered Sirolimus-eluting Stent Versus the Nano Polymer-free Sirolimus-eluting Stent in the Treatment of Patients With de Novo Stenotic Lesions

To evaluate the safety, efficacy and deliverability of the Combo bio-engineered sirolimus-eluting stent versus the Nano polymer-free sirolimus- eluting stents in the treatment of patients with de novo stenotic lesions of native coronary artery.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–75 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Daqing General Oilfield Hospital, Daqing, Heilongjiang, China

Loading trial locations.

About this study

This is a prospective, multi-center, open-label, non-inferiority, randomized controlled trial which plans to enroll 436 subjects. All subjects enrolled will be randomly assigned to the test group (n=218) and the control group (n=218). Subjects in the test group and the control group will receive Combo stents and Nano stents respectively.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients with clinical evidence of asymptomatic or symptomatic ischemic heart disease, stable or unstable angina, old myocardial infarction;
  • De novo lesions of native coronary arteries (lesions number ≤2);
  • Target lesion located in one or two different vessels. The number of target lesions in one vessel shall be no more than one;
  • Target vessel diameter between 2.5 and 4.0 mm by visual estimation. Target lesion length ≤ 32mm by visual estimation, which can be covered by one Combo stent with length 38mm or one Nano stent with length 36mm. It is suggested that the selected stent size should cover at least 2 mm (by visual estimation) of normal tissue on each side of the lesion;
  • Target lesion diameter stenosis ≥ 70% by visual estimation;
  • Each target lesion is permitted to implant only one stent at most, except bailout stent;
  • Patients is eligible for PCI and is an acceptable candidate for CABG;
  • Patients with left ventricular ejection fraction (LVEF) ≥40%;
  • Patients who can understand the nature of the study, agree to participate and accept angiographic and clinical follow-up, and have provided written informed consent;

Exclusion criteria

  • Patients with acute myocardial infarction (AMI) within one week;
  • Chronic total occlusion lesion (TIMI 0 flow), Left main disease, Ostial lesion, and/or triple-vessel lesion that might require treatment, bifurcation lesions with a side branch diameter >2.5mm or graft lesions;
  • Heavily calcified or tortuous lesions which cannot be successfully pre-dilated, and lesions which are not suitable for stent delivery and deployment;
  • In-stent restenosis;
  • Thrombotic lesion;
  • Patients who had received any other stent in the past six months;
  • Patients with acute or chronic renal dysfunction (defined as creatinine greater than 2.0 mg/dl);
  • Patients with cardiogenic shock, acute infection, known bleeding or coagulation disorder, or with a history of active gastrointestinal bleeding, ulcer, cerebral hemorrhage or subarachnoid hemorrhage and stroke within 6 months;
  • Patients who are allergic to aspirin, clopidogrel, ticagrelor, ticlopidine, heparin, contrast agent, sirolimus, stainless steel , polymer, or with contraindication to aspirin or clopidogrel or ticagrelor;
  • Patients who had previously received murine therapeutic antibodies and exhibited sensitization through the production of HAMA;
  • Patients with a life expectancy less than 1year;
  • Patients who had participated in another investigational drug or device trial that has not completed the primary endpoint;
  • Patient who has received any organ transplant or is on a waiting list for any organ transplant;
  • Patient is in the opinion of the investigator, unable to comply with the requirements of the study protocol

Treatment and study plan

OrbusNeich Combo stent™

Device

The Combo Stent is composed of the OrbusNeich R stent™, with an abluminal coating of a bioabsorbable polymer matrix formulated with sirolimus for sustained release, and an anti-CD34 antibody cell capture coating on the luminal surface.

sirolimus-eluting stent system

Device

Other names: Nano Polymer-free sirolimus-eluting stent system

Primary outcomes

  1. In-segment late lumen loss (LLL)

    Time frame: 9 months post-procedure

    In-segment late lumen loss (LLL) refers to within the margins of the stent and 5 mm proximal and 5 mm distal to the stent.

Secondary outcomes

  1. Device-oriented target lesion failure (TLF)

    Time frame: 30 days, 6 months, 12 months and annually up to 5 years

    The device-oriented target lesion failure (TLF) defined as a composite of cardiac death, target vessel myocardial infarction (MI), and ischemia-driven target lesion revascularization (i-TLR)

  2. Patient-oriented composite endpoint

    Time frame: 30 days, 6 months, 12 months and annually up to 5 years

    The patient-oriented composite endpoint includes all-cause death, all MIs, or any revascularization

  3. In-stent late lumen loss (LLL)

    Time frame: 9 months post-procedure

  4. In-stent and In-segment binary restenosis (BR)

    Time frame: 9 months post-procedure

  5. In-stent and In-segment minimal lumen diameter (MLD)

    Time frame: 9 months post-procedure

  6. Definite and probable stent thrombosis (ST)

    Time frame: acute (0-24 hours), sub-acute (24 Hours to 30 Days), late (30 Days to 1 year) and very late (1 year to 5 years) period per Academic Research Consortium (ARC) definition criteria

    Definite and probable stent thrombosis (ST) in acute, sub-acute, late and very late period per Academic Research Consortium (ARC) definition criteria

Sponsors and collaborators

Lead sponsor

OrbusNeich

Industry

Collaborators

  • CCRF Inc., Beijing, China
  • OrbusNeich Medical (Shenzhen), Co. Ltd.

Registry information

Official study title

RECOVERY: A Prospective, Multi-center, Randomized Controlled Trial Evaluating the Safety and Efficacy of the Combo Bio-engineered Sirolimus-eluting Stent Versus the Nano Polymer-free Sirolimus-eluting Stent in the Treatment of Patients With de Novo Stenotic Lesions of Native Coronary Artery

Acronym: RECOVERY

Important dates

Study start
2015
Primary completion
2017
Study completion
2021
First posted
Sep 4, 2015
Registry last updated
Sep 9, 2021

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.