Peiga Medical Technology (Suzhou) Co., Ltd
Suzhou, Jiangsu, 215025, China
NCT Number: NCT04744857
The TaurusOne® transcatheter aortic valve system with retrievable delivery catheter system is evaluated the safety and effectiveness for the delivery of artificial aortic valve in a prospective, multicenter, single-arm clinical trial.
Looking for future studies?
Notify Me70 year and older
All sexes
Interventional
Not applicable
Suzhou, Jiangsu, 215025, China
The TaurusOne® transcatheter aortic valve system with retrievable delivery catheter system is evaluated the safety and effectiveness for the delivery of artificial aortic valve in a prospective, multicenter, single-arm clinical trial. According to the inclusion and exclusion criteria, sixty patients are planed been enrolled and implanted with TaurusOne® .Patients are seen at pre and post procedure, discharge, 30 days. The main follow-up included clinical symptoms and signs, cardiac ultrasound, CT, etc. The outcome included immediate device success, procedure success, And the major cardiovascular and cerebrovascular adverse events (MACCE, including mortality, stroke, myocardial infarction, reoperation, arrhythmia, conduction block).
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Using the grip-loading system, the artificial aortic valve was squeezed and loaded into the sheath of the transporter through the vascular approach.The artificial aortic valve is delivered and positioned at the correct anatomical position for release. For example, the artificial main valve is displayed after partial release If the aortic valve is not in the correct anatomical position, the artificial aortic valve can be recovered and placed into the sheath tube of the transporter for re-positioning and release.
Other names: The TaurusOne® transcatheter aortic valve replacement system features a retrievable delivery catheter system
Time frame: 30 days after procedure
Patient-oriented composite event including all-cause death,severe stroke,myocardial infarction, permanent pacemaker implantation,surgical reoperation and valve-in-valve.
Time frame: Immediately after procedure
Device success is defined as
Time frame: 72 hours after procedure/prior to discharge
Procedure success is defined as the artificial aortic valve successfully implanted in the correct anatomical position 72h after surgery or before discharge without severe artificial aortic valve regurgitation or perivalvular leakage.
Time frame: 30 days after procedure
Cardiac function improvement is accessed by NYHA cardiac function classification increases from baseline to 30 days.
Time frame: 30 days after procedure
Quality of Life of patients accessed by EuroQol-5 Dimensions (EQ-5D) Questionnaire. The higher scores mean a worse health state. Recording changes from baseline to 30 days.
Time frame: Immediately after procedure
Product Performance includes grip loading, emptying , delivery, release, retrace, development and retrieval performance of delivery catheter system. Every item measured by:1=good 2=average 3=poor.
Time frame: Immediately after procedure
The rate of operative complication
Time frame: 30 days after procedure
Incidence of MACCEs (including mortality, stroke, myocardial infarction, and so on surgery, arrhythmias, conduction blocks) during the trial.
Time frame: 30 days after procedure
Incidence of MAVREs (including artificial aortic valve-related death, permanent cardiac pacemaker or defibrillator implantation, artificial aortic valve embolism or thrombosis, artificial aortic valve loss of function) during the trial.
Time frame: 30 days after procedure
Rate of patients with hemorrhage during the trial.
Time frame: 30 days after procedure
Rate of patients with acute kidney injury during the trial.
Time frame: 30 days after procedure
Rate of patients with Other TAVI related complications during the trial. Other TAVI related complications include conversion to surgery, accidental cardiopulmonary mechanical assistance, coronary occlusion, ventricular septal perforation, mitral valve damage or loss of function, pericardial tamponade, endocarditis, valvular thrombosis, valvular ectopic (displacement, embolization, erroneous release), etc.
Time frame: 30 days after procedure
Valvular function include valve stenosis, valve regurgitation, valve function (such as opening area, pressure gradient), perivalvular leakage, etc.
Peijia Medical Technology (Suzhou) Co., Ltd.
Industry
A Prospective,Multicenter, Single-arm Clinical Trial to Evaluate Safety and Efficacy of TaurusOne® Transcatheter Aortic Valve Replacement System With Retrievable Delivery Catheter System
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06894550
Altitude, Altitude Sickness
Bern, Canton of Bern, Switzerland
View Trial DetailsNCT06211296
Aortic Stenosis, Aortic Valve Disease
Thousand Oaks, California, United States
View Trial DetailsNCT05035277
Aortic Stenosis, Aortic Valve Disease
Oslo, Norway
View Trial DetailsNCT06372301
Aortic Stenosis, Aortic Valve Disease
Aarhus, Denmark
View Trial Details