Methodist Healthcare System
San Antonio, Texas, 78229, United States
NCT Number: NCT06938217
The current standard of care (SOC) for treatment of patients with acute respiratory distress syndrome (ARDS), inhalation injury, volume overload, and/or pulmonary dysfunction is mechanical ventilation (MV). However, these techniques are associated with several complications after prolonged use, including risk of infection, increased sedation requirements, pulmonary edema, ventilator-induced lung injury (VILI), barotrauma, and multi-organ failure.
Extracorporeal life support (ECLS) has been used to successfully minimize, replace, or avoid the use of MV. This concept is critical as it permits ultra-lung protective MV settings, mobilization, early ambulation of patients, and timely extubation (when appropriate).
Conventional ECLS typically requires blood flows of 3-6 L/min, and its cannula sizes range from 21-25 Fr. This is by definition "high-flow" as it constitutes near-complete extracorporeal circulation of patient's circulating blood volume. On the other hand, low-flow ECLS at 1-2.5 L/min has been shown to prevent deleterious shifts in pH and PaCO2 at a lower level of invasiveness, and its cannula sizes range from 19-20 Fr dual lumen cannulas (which are associated with less serial dilation). The investigators propose the use of a low-flow circuit to include the NovaLung system in conjunction with a smaller tubing set and cannula to enable earlier utilization of ECLS with less invasiveness and smaller catheters. Specifically, the study will either utilize the Crescent RA cannula (or equivalent dual-lumen cannula) or use a 15-25 Fr cannula, both with 3/8 tubing/step-down tubing, as needed, for our study. A femoral (fem)-femoral or femoral-internal jugular (IJ) approach may also be used.
Carbon dioxide is six times more diffusible than oxygen across the membrane; thus, carbon dioxide transfers can occur with high efficiency at our targeted blood flows of 1-2.5L/min. Oxygen can still transfer at these blood flows, and low flow can improve oxygen levels to some degree.
There are three benchtop-based manuscripts that suggest that low-flow ECMO is associated with a potential increase in factors that increase the risk of bleeding complications/circuit changes. However, the manuscripts either tested <1 L/min blood flow rates, or the effect of cannula size was not considered. None of them included the biological component of endothelial interaction. Mitigating the risk of bleeding complications by will be completed by administering anticoagulants with a target PTT of 40-50 seconds, and by monitoring the patients and their coagulation panels closely. There may be less risk of circuit clotting in our study because of chosen flow rates (1-2.5 L/min).
Interested in participating?
Request Info18 year–65 year
All sexes
Interventional
Not applicable
San Antonio, Texas, 78229, United States
The investigators focus is to demonstrate the safety, feasibility, and efficacy of low-flow ECLS as a treatment for multiple respiratory conditions (including ARDS, volume overload, obstructive and restrictive pulmonary diseases, hypoxia) in conjunction with MV.
BACKGROUND
The two most significant trials in the last five years investigating strategies around low-flow ECLS with the intent of CO2 reduction/ventilator reduction are as follows:
The investigators note several differences in their protocol that differentiates it from the REST trial. First, the investigators will use a device capable of obtaining higher blood flow rates with higher initial targets of blood flow (1-2.5L/minute). Specifically, the study will use a low-flow circuit to include the NovaLung system (Fresenius Medical Care, Waltham MA) in conjunction with a smaller tubing set and cannula (15 - 25 Fr versus 23 - 31 for conventional ECMO, as needed) to enable earlier utilization of ECLS with less invasiveness and smaller catheters. Second, the current study includes broader limitations to length of time of the device (e.g. 28 days versus 7 days), which may be a more pragmatic and generalizable approach.
RATIONALE The current standard of care (SOC) for treatment of patients with acute respiratory distress syndrome (ARDS), inhalation injury, volume overload, and/or pulmonary dysfunction is mechanical ventilation (MV). However, these techniques are associated with several complications after prolonged use, including risk of infection, increased sedation requirements, pulmonary edema, ventilator-induced lung injury (VILI), barotrauma, and multi-organ failure. Extracorporeal life support (ECLS) has been used to successfully minimize, replace, or avoid the use of MV. This concept is critical as it permits ultra-lung protective MV settings, mobilization, early ambulation of patients, and timely extubation (when appropriate).
Low-flow ECLS has been shown to prevent deleterious shifts in pH and PaCO2 at a lower level of invasiveness. The investigators hypothesize that the use of low-flow ECLS will be a safe option for the treatment of pulmonary dysfunction and mild and moderate ARDS, that it will significantly reduce MV settings, and that it will decrease the need for intubation for patients requiring respiratory support for either failure to oxygenate or ventilate.
PROCEDURES Subjects meeting criteria for enrollment will be screened by the Principal Investigator or any delegates assigned to review the patient's chart. A HIPAA authorization and informed consent will be provided by the subject or legally authorized representative (LAR) prior to conducting any additional research procedures.
Patients enrolled after consent is obtained will be placed on Low-Flow ECMO by trained physicians. Subjects will be cannulated in one of two ways, either at bedside with the use of radiographic imaging to confirm accurate cannula placement, or in the catheter laboratory under fluoroscopy with safety measures in place to appropriately monitor the patient's vital signs, ventilatory measurements, and LF ECMO settings.
Initiation of LF ECMO will require cannula placement and connection to the Novalung XLung extracorporeal circuit. Size and type of cannula will be determined by the investigator and documented at cannulation. The XLung will be used with circuit to accommodate lower flows necessary to efficiently move 1-2.5 LPM of blood through the oxygenator. Subjects treated with low-flow ECMO will receive systemic anticoagulation per standard of care for patients treated with ECLS. After cannulation and placement on LF ECMO, blood gases will be drawn from the patient, pre-Xlung, and post-Xlung to assess the function of the Novalung system, patient's stability after initiation, and the ability to effectively wean ventilatory support.
Multiple labs will be collected and documented as routine standard of care while others will be collected prior to device implementation and during the duration of therapy for research purposes. The following is considered standard of care (as needed, daily): arterial blood gases, lactate, platelet count. Standard of care costs are billed to insurance. The following are considered research costs (prior to device initiation, within one hour of device initiation [if collected]): arterial blood gases, lactate, platelet count. Heparin doses, aPTT, ACT, anti-Xa, plasma-free hemoglobin, pre- and post-membrane analyses are all research costs, in addition to inflammatory markers and functional outcomes (6MWT, quality of life questionnaires). All research costs are covered by the awarded grant.
Biospecimens: Approximately 2 mLs of blood will be collected in tubes containing EDTA at least seven times (pre-ECLS, daily, post-ECLS, discharge, 30-, 60-, 90-days post-discharge, as available). Blood will be taken prior to the administration of anesthesia (when applicable), from an existing catheter, or by venipuncture. The samples will be placed on ice, and blood will be separated by centrifugation within 30 minutes of collection to yield roughly 1 mL of plasma. The samples will be stored in appropriate freezer (long-term of ≤-80ºC or temporarily ≤-20°C). Urine (up to 10 mLs) will be collected either from the subject's urinary retention catheter or directly from the subject in a urine cup, and it will be stored in appropriate freezer (long-term of ≤ -80ºC or temporarily ≤ -20°C) until analysis.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Acute hypoxemic respiratory failure meeting all the following criteria:
Exclusion criteria
low-flow ECMO, defined as 1-2.5 L of blood flow/min.
Time frame: Documented at 28 Days
Ventilator-free days in the first 28 days
Time frame: Documented at discharge from the ICU, through study completion (an average of 21 days)
Time frame: Documented at discharge from the hospital, through study completion (an average of 21 days)
Length of Stay in Hospital
Time frame: Documented at occurrence or death, or at discharge from the hospital, through study completion (an average of 21 days)
In-hospital mortality
Time frame: Documented daily throughout hospitalization until discharged, through study completion (an average of 21 days)
Time to and duration of lung protective settings (Pplat≤ 28 cm H2O [protective], Pplat ≤ 25 cm H2O [ultraprotective level])
Time frame: Documented daily throughout hospitalization until discharged, through study completion (an average of 21 days)
Conversion to full ECMO support (>2.5L/min Flow)
Time frame: Documented at occurrence, or daily at minimum through study completion, through study completion (an average of 21 days)
Serious adverse events (SAEs) and Grade 3 and 4 adverse events (AEs) per Common Terminology Criteria for Adverse Events (CTCAE) v5.0 (November 2017)
Time frame: Documented daily throughout hospitalization until discharged, through study completion (an average of 21 days)
Anticoagulation (rate); results of clinical coagulation panel collected throughout hospital stay
Time frame: Documented hourly and daily throughout hospitalization until discharged, through study completion (an average of 21 days)
Tidal Volume (ml)
Time frame: Documented hourly and daily throughout hospitalization until discharged, through study completion (an average of 21 days)
Minute Ventilation (L/min)
Time frame: Documented hourly and daily throughout hospitalization until discharged, through study completion (an average of 21 days)
Respiratory Rate (bpm)
Time frame: Documented hourly and daily throughout hospitalization until discharged, through study completion (an average of 21 days)
Heart Rate (bpm)
Time frame: Documented as needed for clinical care (typically Q6) throughout hospitalization until discharged, through study completion (an average of 21 days)
Arterial Blood Gas (O2CT, O2Sat, PaO2, PaCO2, pH, HCO3)
Time frame: Pre-ECMO, daily on ECMO, at decannulation, and at 30/60/90 day follow-up apointments
Inflammatory markers in plasma and in urine
Institute for Extracorporeal Life Support
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07463885
Acute Hypoxemic Respiratory Failure, Acute Respiratory Distress Syndrome (ARDS)
View Trial DetailsNCT06936618
Acute Hypoxemic Respiratory Failure, Acute Respiratory Distress Syndrome (ARDS)
Bangkok, Thailand
View Trial DetailsNCT05150483
Acute Hypoxemic Respiratory Failure, Acute Respiratory Distress Syndrome
Athens, Attica, Greece
View Trial DetailsNCT03642002
Acute Hypercapnic Respiratory Failure, Acute Hypoxemic Respiratory Failure
New York, United States
View Trial Details