Nanjing First Hospital
Nanjing, Jiangsu, 210006, China
NCT Number: NCT04119986
In 1970, the first percutaneous balloon coronary angioplasty opened a new chapter of interventional therapy. However, the incidence of intracoronary restenosis was about 30%. Subsequently, bare metal stents and drug-eluting stents (DES) reduced the incidence of in-stent restenosis (ISR) to 5%-10% and it was still a bottleneck treated by percutaneous coronary intervention (PCI). Currently, ISR is mainly treated by balloon angioplasty, stent implantation and coronary artery bypass grafting.
In 2014, the guidelines of the European Society of Cardiology recommended that drug balloon therapy (DCB) and new generation DES should be the preferred strategies for ISR treatment. Compared with DES, DCB treatment can avoid the inflammation of intima caused by multi-layer stent strut, and reduce the risk of intimal hyperplasia and thrombosis in stent. However, DCB lacks sustained radial support. Even if the residual stenosis is less than 30% after sufficient pre-dilation, the elastic retraction of the intima still exists. In addition, the antiproliferative effect of paclitaxel is significantly worse than that of sirolimus and its derivatives, and there is a lack of long-term sustained release of anti-proliferative drugs. Compared with DCB, DES can obtain long-term stable radial support and long-term anti-proliferation effect, but stent struts exposed in the vascular lumen are at risk of stent thrombosis. The new generation of DES improves the design of stent platform, improves the polymer coating, and applies new anti-proliferative drugs. It effectively reduces the inflammation of vascular wall, speeds up the process of vascular re-endothelialization, promotes early vascular repair, and significantly reduces the incidence of stent thrombosis. Recent BIOLUXRCT, RESTORE and DARE studies provide more powerful evidence for the treatment of ISR by new generation DES.
Quantitative flow ratio (QFR) is the second generation FFR detectional method based on coronary contrast image. The latest FAVOR II results also confirm that QFR is more sensitive and specific than quantitative coronary analysis (QCA) in the diagnosis of myocardial ischemia caused by coronary artery stenosis. However, there is no report of ISR treated with DCB under the guidance of QFR. The aim of this study was to evaluate the safety and efficacy of DCB in the treatment of in-stent restenosis in patients with coronary heart disease (CHD) under the guidance of QFR compared with DES implantation.
Trial opening soon.
Get Notified18 year–100 year
All sexes
Interventional
Not applicable
Nanjing, Jiangsu, 210006, China
The current study is designed as a multicenter, randomized and prospective study aiming to evaluate the safety and efficacy of drug balloon therapy for ISR in patients with CHD under the guidance of QFR compared with DES implantation. Based on previous study reported, the incidence rate of target lesion failure is about 3% in patients with ISR undergoing DES implantation. And the design of non-inferiority study was performed in our study. Moreover, the investigators estimated 10% loss follow-up of these patients in each arm. As a result, a total of 220 patients with ISR were required, and with 110 patients per group as a ratio of 1:1 randomization.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
● Meet the diagnostic criteria for patients with coronary in-stent restenosis and QFR<0.8 of target lesion in the coronary stent
Exclusion criteria
Balloon/vessel diameter ratio 0.8-1.0, 8-12 ATM (atmosphere), lasting for >30 seconds.
with regular techniques
Time frame: Follow-up coronary angiography at 12 months after the procedure
The incidence rate of late lumen loss between DCB treated group and DES treated group evaluated by quantitative coronary analysis in patients with ISR
Time frame: Clinical follow up at 30 days, 6, 9 and 12 months after the operation
The incidence rate of patient-related ischemic events including all myocardial infarction, any revascularization and all-cause death
Contact information is provided by the study sponsor or research team.
Fei Ye, MD
CONTACT
Xiangqi Wu, MD
CONTACT
Nanjing First Hospital, Nanjing Medical University
Other
Safety and Efficacy of Drug Coated Balloon Therapy for Coronary In-stent Restenosis in Patients With Coronary Heart Disease Under the Guidance of QFR (UNIQUE-DCB-II Study)
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07549282
Cardiovascular Diseases, Coronary Disease
Hangzhou, Zhejiang, China
View Trial DetailsNCT07723222
Apnea, Cardiovascular Autonomic Neuropathy (CAN)
View Trial DetailsNCT07657676
Body Weight, Cardiovascular Diseases
Beijing, Beijing Municipality, China
View Trial DetailsNCT07260552
Cardiovascular Diseases, Coronary Disease
View Trial Details