Since Gruntzig successfully performed percutaneous coronary balloon angioplasty in 1977, percutaneous coronary intervention has developed rapidly. From bare metal stents to drug-eluting stents (DES), the symptoms and prognosis of patients with coronary heart disease (CHD) have been greatly improved. Although DES has reduced the probability of in-stent restenosis (ISR) and thrombosis compared with BMS since its clinical application, it can not completely solve this problem. Even if the new generation of DES requires revascularization, the incidence of ISR is still as high as 5%-10%. DES treatment is associated with delayed endothelial healing, late acquired poor stent adherence and new atherosclerosis, which lead to late ISR and thrombosis. In addition, DES is still not ideal for the treatment of small vessel disease, diffuse long lesion and bifurcation lesion. Therefore, drug coated balloon (DCB) has attracted people's attention. Balloon-loaded antiproliferative drugs can fully release the drugs to the vascular wall during balloon dilation, which can inhibit the restenosis process from the beginning of injury, and show good efficacy and safety in some specific lesions. Many clinical studies have shown that DCB has good efficacy and safety in some specific lesions (ISR, small vessel disease, bifurcation disease, in situ lesion). Especially in the treatment of ISR, researchers believe that its efficacy is not inferior to DES, and it has the advantage of non-metal residues.
Quantitative flow ratio (QFR) is the second generation FFR detection method based on angiographic images. The diagnostic accuracy of QFR 0.80 for myocardial ischemic stenosis was 92.7%. Compared with QCA, the positive predictive value and negative predictive value of QFR were also significantly better than those of QCA. The latest FAVOR II results also confirm that QFR is more sensitive and specific in diagnosing myocardial ischemia caused by coronary artery stenosis than QCA, and confirm the feasibility of using QFR online in catheter lab to evaluate the functional significance of coronary artery critical lesions. However, there is no report on the treatment of de novo lesions in patients with coronary heart disease by DCB under the guidance of QFR. The aim of this study was to evaluate the safety and efficacy of drug balloon therapy for de novo lesions in patients with CHD under the guidance of QFR compared with DES implantation.
Trial opening soon.
Get Notified18 year–90 year
All sexes
Interventional
Not applicable
Nanjing, Jiangsu, 210006, China
Fei Ye, MD
CONTACT
Fei Ye, MD
PRINCIPAL_INVESTIGATOR
Xiangqi Wu, MD
CONTACT
The current study is designed as a multicenter, randomized and prospective study aiming to evaluate the safety and efficacy of drug balloon therapy for de novo lesions in patients with CHD under the guidance of QFR compared with DES implantation. Based on previous study, the incidence rate of target lesion failure is 5%-10% in patients with CHD undergoing DES implantation. And in the investigators study the expected incidence rate of target lesion failure is up to 5.0 % in patients with CHD after treatment with DCB. Moreover, the investigators estimated 10% loss follow-up of these patients in each arm. As a result, a total of 220 patients with CHD were required, and with 110 patients per group as a ratio of 1:1 randomization.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
●Meet the diagnostic criteria for stable angina pectoris, unstable angina pectoris and acute myocardial infarction and QFR<0.8 of target lesion
Exclusion criteria
Balloon/vessel diameter ratio 0.8-1.0, 8-12 ATM (atmosphere), lasting for >30 seconds
Time frame: Follow-up coronary angiography at 12 months after the procedure
The incidence rate of late lumen loss between DCB treated group and DES treated group evaluated by quantitative coronary analysis in patients with CHD
Time frame: Clinical follow up at 30 days, 6, 9 and 12 months after the procedure
The incidence rate of device-related ischemic events including cardiovascular death, target vessel related myocardial infarction and ischemia-driven revascularization between DCB treated group and DES treated group
Time frame: Clinical follow up at 30 days, 6, 9 and 12 months after the operation
The incidence rate of patient-related ischemic events including all myocardial infarction , any revascularization and all-cause death between DCB treated group and DES treated group
Contact information is provided by the study sponsor or research team.
Fei Ye, MD
CONTACT
Xiangqi Wu, MD
CONTACT
Nanjing First Hospital, Nanjing Medical University
Other
Safety and Efficacy of Drug Coated Balloon Therapy for de Novo Lesions in Patients With Coronary Heart Disease Under the Guidance of QFR (UNIQUE-DCB-I Study )
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07549282
Cardiovascular Diseases, Coronary Disease
Hangzhou, Zhejiang, China
View Trial DetailsNCT07723222
Apnea, Cardiovascular Autonomic Neuropathy (CAN)
View Trial DetailsNCT07657676
Body Weight, Cardiovascular Diseases
Beijing, Beijing Municipality, China
View Trial DetailsNCT07260552
Cardiovascular Diseases, Coronary Disease
View Trial Details