NCT Number: NCT04329754

Safety and Efficacy of a Novel Hydrophobic Acrylic IOL - iPure: a Randomised Study

In this study the rotational stability and performance - with respect to glistening and PCO formation - of a new hydrophobic acrylic IOL (IPure, PhysIOL, Belgium) will be compared to a gold standard IOL (AMO ZCB00) in a randomized controlled fashion. Fifty eyes of 50 patients will be included. 25 patients will receive the iPure and 25 patients will receive the standard IOL. Study hypothesis: The iPure IOL shows better rotational stability compared to the standard IOL. A clinically relevant difference for rotational stability is defined as 2°.

Completed

Looking for future studies?

Notify Me

Key information

Age range

21 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch Hospital Vienna

Vienna, 1140, Austria

About this study

Although there may be no direct benefit to the subjects under study, the investigation will assess the stability which determines the efficacy for future toric optics and the amount of glistening and PCO formation of the IPure and ZCB00 hydrophobic acrylic IOLs.

25 eyes of 25 patients will be recruited for each IOL, that is 50 eyes of 50 patients. The randomization will be done with a binomial law. The IOL have a priori the same IOL constants which eliminates the necessity to know which IOL is going to be implanted at the preoperative time. A clinically relevant difference for rotational stability will be 2°. The reasonable standard deviation of the position of an IOL in the eye is 2.4°. A total of 48 patients is necessary for a probability of 80% to measure a clinically relevant difference concerning the IOL stability.

In the week before surgery, the eye to be operated is examined at the slit-lamp and by indirect fundoscopy and measurement of intraocular pressure (IOP) will be performed routinely. Additionally, routine biometry is performed using the IOLMaster (Zeiss Meditec AG, Jena, Germany) for axial length measurement, K-readings and anterior chamber depth (ACD) measurements.

Randomisation will be performed using online randomisation and patients will be allocated 1:1 either to the study group (iPure group), or to the control group (ZCB00).

A self sealing incision, injection of viscoelastic substance, capsulorhexis, phacoemulsification, irrigation/aspiration of cortical material and injection of viscoelastic substance into the capsular bag are performed in a standardised fashion. The IOL is implanted via injector into the capsular bag. Following the implantation of the IOL, the viscoelastic substance is aspirated thoroughly from the anterior chamber, as well as retro-lentally, to assure complete removal of the OVD.

Any deviation from the standard protocol will be recorded peroperatively. Follow-ups will be performed 1-2 hours, 1 month, 12 months and 24 months after cataract surgery.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Age-related cataract
  • Age 21 and older
  • Visual Acuity > 0.05
  • Normal findings in the medical history and physical examination unless the investigator considers an abnormality to be clinically irrelevant.

Exclusion criteria

  • Relevant other ophthalmic diseases such as pseudoexfoliation syndrome, floppy iris syndrome, corneal pathologies
  • Previous ocular surgery or trauma.
  • Pregnancy (pregnancy test will be taken pre-operatively in women of reproductive age)

Treatment and study plan

Cataract surgery

Device

Cataract surgery with implantation of an intraocular lens (IOL)

Primary outcomes

  1. Rotational Stability

    Time frame: 2 years

    measured using the Purkinje meter (Murcia University) and retroillumination images (degrees of rotation)

Secondary outcomes

  1. Glistening

    Time frame: 2 years

    subjective measurement (0 to 4, 0 no glistening, 4 sever glistening)

  2. visual acuity

    Time frame: 2 years

    assessed by ETDRS charts at 4m

  3. PCO

    Time frame: 2 years

    scored with AQUA (0 to 10, 0 no PCO, 10 sever PCO) and the number of Nd:YAG capsulotomies

  4. Decentration in mm

    Time frame: 2 years

    measured by Purkinjemeter

  5. Tilt in degrees

    Time frame: 2 years

    measured by Purkinjemeter

  6. Capsulorhexis area

    Time frame: 2 years

    assessed by retroillumination images

  7. Anterior chamber depth

    Time frame: 2 years

    assessed by AC Master (in mm)

Sponsors and collaborators

Lead sponsor

Vienna Institute for Research in Ocular Surgery

Other

Registry information

Important dates

Study start
2012
Primary completion
2015
Study completion
2015
First posted
Apr 1, 2020
Registry last updated
Oct 17, 2022

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.