Skip to main content
OpenTrials
Completed

NCT Number: NCT01716117

Safety and Effectiveness of an Intracranial Aneurysm Embolization System for Treating Large or Giant Wide Neck Aneurysms

This clinical research study is designed to determine safety and effectiveness of the Surpass Flow Diverter (Surpass System), an investigational device developed to treat wide-neck, large or giant intracranial aneurysms. An intracranial aneurysm is a bulge in the wall of a blood vessel in the brain. The bulge is caused by a weakening of the vessel wall. If left untreated, the bulge may continue to grow larger and ultimately the vessel may break open (rupture), resulting in serious bleeding into or around the brain. The information collected from this study will be used to evaluate how well patients do when treated with the Surpass System both immediately after treatment of an aneurysm and over a long period of time (5 years).

Completed

Looking for future studies?

Notify Me

Key information

Age range

19 year–80 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

UMC St Radboud, Nijmegen, Netherlands

Loading trial locations.

About this study

The objective of this study is to determine safety and effectiveness of the Surpass Flow Diverter (Surpass System) in the endovascular treatment of large or giant wide-necked intracranial aneurysms in the internal carotid artery up to the terminus. The Surpass Flow Diverter is an intracranial implant designed to be placed in a parent artery so as to divert blood flow away from an aneurysm. Use of the Surpass System may be associated with a decrease in neurological death or ipsilateral stroke in patients with large or giant wide-neck aneurysms. In a given patient, the Surpass System will be deemed effective if treatment results in complete occlusion of their aneurysm without clinically significant stenosis of the parent artery, or requires retreatment of the aneurysm through 12 months.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Age 19 to 80 years
  • Subject or legal representative is willing and able to give informed consent
  • Subject has a single targeted intracranial aneurysm
  • Subject agrees to return to the treating Investigator for all scheduled follow up visits and is capable of returning to the hospital for follow up

Exclusion criteria

  • Known allergy or contraindication to aspirin, clopidogrel/Plavix, heparin, local or general anesthesia
  • Known history of life threatening allergy to contrast dye
  • Known allergy to nickel, chromium cobalt, tungsten or platinum
  • Subject has documented resistance to clopidogrel/Plavix
  • Major surgery within previous 30 days or planned in the next 120 days after enrollment date
  • Previous intracranial implant associated with the symptomatic distribution within the past 12 weeks prior to treatment date
  • Stenting, angioplasty, or endarterectomy of an extracranial (carotid or vertebral artery) or intracranial artery within 30 days prior to treatment date
  • Any previous stenting of parent artery at or proximal to the aneurysm where it would interfere with the placement and proper apposition of the device
  • Any previous coiling where it would interfere with the placement and proper apposition of the device
  • Platelet count less than 100,000 cells/mm3 or known platelet dysfunction
  • More than one intracranial aneurysm (IA) that requires treatment within 12 months
  • Asymptomatic extradural aneurysms requiring treatment
  • Contraindication to CT scan or MRI
  • Severe neurological deficit that renders the subject incapable of living independently
  • Unstable neurological deficit (i.e., worsening of clinical condition in the last 30 days)
  • Evidence of active infection at the time of treatment
  • Dementia or psychiatric problem that prevents the patient from completing required follow up
  • Co-morbid conditions that may limit survival to less than 24 months
  • Serum creatinine greater or equal to 2.5 mg/dL
  • Female subjects who are pregnant or planning to become pregnant within the study period
  • Subject with anatomy not appropriate for endovascular treatment due to severe intracranial vessel tortuosity or stenosis
  • Extra-cranial stenosis or parent vessel with stenosis greater than 50% in the area proximal to the aneurysm
  • Other known serious concurrent medical conditions
  • History of intracranial vasospasm not responsive to medical therapy
  • Subject with an intracranial mass, or is undergoing radiation therapy for carcinoma or sarcoma of the head or neck region
  • Subject has a history of bleeding diathesis or coagulopathy, international normalized ratio (INR) greater than 1.5, or will refuse blood transfusions
  • Subject had a subarachnoid hemorrhage within 30 days prior to the enrollment date
  • Subject has a non-treated arteriovenous malformation (AVM) in the territory of the target aneurysm
  • Inability to understand the study or a history of non-compliance with medical advice
  • Current use of illicit substance
  • Enrollment in another trial involving an investigational product
  • Subject has a need for long-term use of anticoagulants (i.e., Warfarin, Dabigatran)

Treatment and study plan

Surpass Flow Diverter

Device

Treatment of an intracranial aneurysm involves the placement of a specially designed metallic mesh tube in a vessel in the brain where an aneurysm is located. The device looks like a fishnet sock with both ends open. Each device is delivered through a small catheter (a long, flexible tube). The catheter containing the device is inserted and advanced into a vessel in the brain. The device is then placed in the brain vessel by releasing it from the catheter. Once the device is placed inside the brain vessel, it is intended to reinforce the area of the vessel that is weakened and bulging (the aneurysm), and to cause blood to flow down the vessel and away from the aneurysm while allowing blood in the aneurysm to clot. This procedure is called an endovascular aneurysm treatment because the device is delivered through the blood vessels.

Other names: Flow diverter, Endovascular aneurysm treatment

Primary outcomes

  1. mITT Primary Effectiveness Endpoint. Based on Subjects With 100% Occlusion of the Aneurysm Without Clinically Significant Stenosis of the Parent Artery, and Without Any Subsequent Treatment of the Target Aneurysm at the 12 Month Follow up Visit.

    Time frame: 12 months

    Percent of subjects with 100% occlusion of the aneurysm without clinically significant stenosis (defined as less than or equal to 50% stenosis) of the parent artery based on core lab evaluation of the 12 month follow up angiogram and without any subsequent treatment of the target aneurysm at the 12 month follow up visit.

  2. mITT Primary Safety Endpoint. Based on Subjects Experiencing Neurologic Death or Major Ipsilateral Stroke Through 12 Month Follow-up.

    Time frame: 12 months

    Subjects experiencing neurologic death or major ipsilateral stroke through 12 months.

Secondary outcomes

  1. Raymond-Roy Score Per Core Lab Assessment Based on Device Apposition at 12 Months Post-Procedure

    Time frame: 12 months

    The Raymond-Roy intracranial aneurysm occlusion classification was used to assess the rate of aneurysm occlusion at the time of primary endpoint assessment (12 months). Occlusion rates were reported as Class I: complete obliteration (best); Class II: residual neck; Class III: residual aneurysm (worse).

Other outcomes

  1. Clinical Events Committee (CEC) Adjudicated Rate of Minor Strokes Through 12 Month Follow-Up

    Time frame: 12 Months

    Patients with minor strokes through 12 months

  2. Subgroup Analysis of Primary Effectiveness Endpoint Based on Subject Age ≥ 65 Years Versus < 65 Years in mITT Population

    Time frame: 12 Months

    Primary effectiveness by age group

  3. CEC Adjudicated Primary Effectiveness Endpoint Outcomes for Giant and Non-Giant (Large) Intracranial Aneurysms Through 12 Month Follow-Up - mITT Population

    Time frame: 12 Months

    Primary effectiveness by intracranial aneurysm size

  4. Number of Surpass Streamline Flow Diverters Implanted Per Subject in SCENT Trial - mITT and Roll-In Populations

    Time frame: 12 Months

    Number of devices implanted in subjects by study population

Sponsors and collaborators

Lead sponsor

Stryker Neurovascular

Industry

Registry information

Official study title

The Surpass Intracranial Aneurysm Embolization System Pivotal Trial to Treat Large or Giant Wide Neck Aneurysms (SCENT Trial)

Acronym: SCENT

Important dates

Study start
2012
Primary completion
2016
Study completion
2022
First posted
Oct 29, 2012
Registry last updated
Dec 19, 2022

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.