NCT Number: NCT05582304
This will be a split-plot design, randomized, parallel, double-masked feasibility study to evaluate the role of a test lens on contrast sensitivity with and without glare.
Looking for future studies?
Notify Me18 year–65 year
All sexes
Interventional
Not applicable
Athens, Georgia, 30602, United States
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Potential subjects must satisfy all of the following criteria to be enrolled in the study:
The subject must:
Exclusion criteria
Potential subjects who meet any of the following criteria will be excluded from participating in the study:
The subject must not:
ACUVUE OASYS MAX 1-Day with TearStable Technology and OptiBlue Light Filter
ACUVUE OASYS 1-Day with HydraLuxe Technology
Time frame: Up to 2 hours post-fitting
Photopic contrast sensitivity was measured under bright light conditions (~120 cd/m2) with a broadband glare source at five spatial frequencies (1.6, 3.2, 8, 16 and 24 cpd) using the University of Georgia system. The area under the log contrast sensitivity function (AULCSF) was derived by first calculating the logarithm of contrast sensitivity as logCS = log10(contrast sensitivity), and then AULCSF was calculated using logCS and the log (base 10) of each spatial frequency based on the trapezoidal rule per eye per subject. The AULCSF was computed by trapezoidal integration of the logarithm of the contrast sensitivity (vertical axis) as a function of the logarithm of spatial frequency (horizontal axis). The unit of the horizontal axis is log(cpd) since spatial frequency is in the unit of cycles per degree (cpd). Although, sensitivity is a unitless parameter, to aid interpretation, the units of AULCSF are described as log(sensitivity)*log(cpd).
Time frame: Up to 2 hours post-fitting
Mesopic contrast sensitivity was measured under dim light conditions (~3 cd/m2) with a broadband glare source at five spatial frequencies (1.6, 3.2, 8, 16 and 24 cpd) using the University of Georgia system. The area under the log contrast sensitivity function (AULCSF) was derived by first calculating the logarithm of contrast sensitivity as logCS = log10(contrast sensitivity), and then AULCSF was calculated using logCS and the log (base 10) of each spatial frequency based on the trapezoidal rule per eye per subject. The AULCSF was computed by trapezoidal integration of the logarithm of the contrast sensitivity (vertical axis) as a function of the logarithm of spatial frequency (horizontal axis). The unit of the horizontal axis is log(cpd) since spatial frequency is in the unit of cycles per degree (cpd). Although, sensitivity is a unitless parameter, to aid interpretation, the units of AULCSF are described as log(sensitivity)*log(cpd).
Johnson & Johnson Vision Care, Inc.
Industry
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07174596
Visual Acuity
Roswell, Georgia, United States
View Trial DetailsNCT07076160
Eye Diseases, Presbyopia
Jacksonville, Florida, United States
View Trial DetailsNCT06864858
Visual Acuity
Maitland, Florida, United States
View Trial DetailsNCT07443215
Visual Acuity
Jacksonville, Florida, United States
View Trial Details