Robotic Versus Electromagnetic Bronchoscopy for Pulmonary LesIon AssessmeNT: (the RELIANT Trial)

This is an investigator-initiated, cluster randomized controlled trial. The primary objective is to compare the diagnostic yield of the Ion™ Endoluminal System (SSCB) to the ILLUMISITE™ Platform (EMN bronchoscopy) in patients undergoing bronchoscopy for peripheral pulmonary lesion (PPL) evaluation.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Vanderbilt University Medical Center

Nashville, Tennessee, 37232, United States

About this study

Peripheral pulmonary lesions (PPLs) are often biopsied to assess for the presence of infection, inflammation, or malignancy. Tissue can be acquired in a variety of ways: surgical resection, percutaneous transthoracic needle biopsy, or bronchoscopic biopsy. Bronchoscopy is commonly pursued to determine PPL etiology, with over 500,000 performed annually in the US alone. Advanced imaging and navigational guidance systems are required to accurately approach small peripheral lesions bronchoscopically. A variety of navigational technologies are currently available, including electromagnetic navigational bronchoscopy (EMN), virtual bronchoscopy, thin and ultrathin bronchoscopes, and endobronchial ultrasound. No comparative data exist regarding the relative performance of these competing technologies, which are all considered standard of care and currently used interchangeably based on personal preferences and availability.

EMN platforms dominate the current navigational bronchoscopy market. The largest prospective multicenter study assessing EMN performance showed a diagnostic yield of 73%. The more recent addition of intraprocedural digital tomosynthesis has been reported to increase EMN diagnostic yield to 75-83%; this feature is included in the ILLUMISITE™ electromagnetic navigational bronchoscopy platform (Medtronic, Minneapolis, MN, U.S.) and is labeled "fluoroscopic navigation".

Recently, the FDA cleared a novel navigational technology: shape-sensing catheter bronchoscopy (SSCB), via the 510(k) pathway. This pathway requires a technical demonstration of safety and efficacy similar to that of an existing predicate device but does not usually require clinical data. Since market release in 2019, single-center prospective cohort data have emerged suggesting SSCB diagnostic yield is comparable to EMN, but no high-quality comparative data exist regarding the relative performance of these two technologies. Despite this important knowledge/data gap, SSCB has become a popular platform in the advanced bronchoscopist community. High-quality comparative data are required to inform optimal patient care. Additionally, EMN and SSCB platforms are considered capital purchases, each costing hundreds of thousands of dollars. Hence, it is also important for health care systems to have high quality data as they consider device purchases. VUMC currently utilizes both SSCB and EMN and they are used interchangeably in our two operating rooms. Patients are typically assigned arbitrarily to procedures using either platform based on operating room availability.

Thus, the investigator proposes a randomized controlled study to test the hypothesis that the diagnostic yield of SSCB is not inferior to EMN in patients undergoing bronchoscopy to biopsy a PPL.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

18 years of age or older at time of bronchoscopy.

Scheduled for navigational bronchoscopy for the evaluation of a peripheral pulmonary lesion.

Exclusion criteria

Enrolled in a different study requiring use of one of these specific platforms (i.e., ILLUMISITE™ Platform (EMN) or Ion™ Endoluminal System (SSCB)).

Subject declines to participate.

Treatment and study plan

ILLUMISITE™ Platform (EMN bronchoscopy)

Device

Providers will utilize the ILLUMISITE™ Platform (EMN) machine to perform a diagnostic bronchoscopy procedure.

Ion™ Endoluminal System (SSCB bronchoscopy)

Device

Providers will utilize the Ion™ Endoluminal System (SSCB) machine to perform a diagnostic bronchoscopy procedure.

Primary outcomes

  1. Diagnostic Yield

    Time frame: 7 days post-enrollment

    Diagnostic yield is defined as the proportion of procedures that results in acquisition of lesional tissue. Lesional tissue is defined by the presence of histopathological findings that readily explain the presence of a pulmonary lesion.

    The following common histopathological findings are pre-specified as lesional:

    i. Malignant ii. "Specific benign" findings accounting for the presence of a PPL

    • organizing pneumonia, or
    • frank purulence/robust neutrophilic inflammation, or
    • granulomatous inflammation, or
    • other specific benign finding findings such as hamartoma, amyloidoma or other uncommon causes of PPLs with distinctive pathological patterns.

Secondary outcomes

  1. Duration of Procedure

    Time frame: Duration of procedure, approximately 60 minutes

    Defined as time from the start of airway registration to the removal of the bronchoscope after completion of navigation procedures

Sponsors and collaborators

Lead sponsor

Vanderbilt University Medical Center

Other

Registry information

Acronym: RELIANT

Important dates

Study start
2023
Primary completion
2024
Study completion
2024
First posted
Jan 30, 2023
Registry last updated
Apr 24, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.