Skip to main content
OpenTrials
Completed

NCT Number: NCT02711566

Robot-based Rehabilitation of Upper Limb Impairment in Multiple Sclerosis

Robot-assisted therapy has proven effective in the neuromotor rehabilitation of eg stroke survivors. Robots can be programmed to interact with patients by guiding their movements, by monitoring their performance and by quantifying the type and degree of their impairment.

A distinctive element of multiple sclerosis is the involvement of a variety of functional systems, in a way that is highly subject-specific. This requires a personalization of treatment, and continuous adaptation to changes in condition. This points to a need for integrating patient assessment, definition of rehabilitation protocols, their administration and the assessment of their outcome.

The goal of this study is to assess, in persons with MS, the efficacy of a type of robot-assisted training that was specifically designed to counteract incoordination and muscle weakness (typical of MS), tailored to individual type and degree of impairment, when compared to simple movement training.

Completed

Looking for future studies?

Notify Me

Key information

About this study

In recent years, the potential of robots in the treatment of persons with motor disabilities has raised considerable interest. These devices may interact with patients by assisting or perturbing their movements, may monitor their performance and even quantify their impairment. Clinical trials involving stroke survivors clearly demonstrated that robot-therapy results in improved motor control. More recently, robot-therapy has been applied to other pathologies. A pilot study carried out by the proponents suggested that Multiple Sclerosis (MS) subjects with predominantly cerebellar symptoms may indeed benefit from robot-therapy. MS subjects with different symptoms may benefit from robot therapy as well, but the variety of symptoms and degrees of impairment that is typical of MS suggests that robots may fully show their potential if therapy is tailored on the individual subjects.

In this study, the proponents aim at extending the results of the above mentioned pilot study to MS subjects with a wider variety of impairments. Based on previous studies on robot therapy with MS subjects and stroke survivors, the proponents will develop and test a robot training exercise that is specifically designed to deal with incoordination and/or muscle weakness. In a randomised controlled trial, the proponents will then assess the possible contribution of this form of robot-therapy to the rehabilitation of MS subjects.

A population of clinically definite MS subjects with different degrees of upper limb impairment was randomised into 2 groups: (i) Haptic training and (ii) Sensorimotor training.

Haptic training was based on a robot-assisted exercise protocol specifically designed to treat cerebellar and motor symptoms in persons with MS by counteracting, respectively, incoordination and muscle weakness. The exercise is based on a motor task - interaction with a virtual mass-spring system under the effect of a resistive load - that requires sophisticated coordination skills. Task difficulty (the time constant of the mass-spring system) and the magnitude of the resistive load (stiffness magnitude of the resistive spring) were automatically adjusted to the individual subjects' upper limb impairment.

In Sensorimotor training, the task is exactly the same, but the robot generates no forces. Hand and target position are displayed on the computer screen. This group allowed quantifying the specific contribution of robot assistance to sensorimotor recovery (if any). Both groups performed 8-10 therapy sessions (1 hour/each, 2-3 times per week). Treatment outcome was assessed in terms of the Nine-Hole Peg Test (9HPT) and the ARAT scores.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion:

  • definite Multiple sclerosis, stable phase of the disease
  • no relapses or worsening >1 in the Expanded Disability Status Scale in the last three months,
  • Expanded Disability Status Scale<7.5,
  • Ashworth score at the upper limb lower than 2,
  • Nine-Hole Peg Test between 30 s and 180 s

Exclusion:

  • previous treatment with robot therapy,
  • presence of severe nystagmus,
  • visual acuity less than 4/10
  • major orthopaedic or other disorders interfering with the protocol

Treatment and study plan

Physioassistant: Haptic training

Device

Subjects in the Haptic training arm had to perform fast-and-accurate reaching movements in different directions. reaching was mediated by a virtual 'tool', consisting of a virtual point mass (m=5 kg) connected to the subjects' hand through a linear spring (stiffness range: Km=200-500 N/m). An additional spring (stiffness range: Kr = 20-70 N/m) was connected between hand a starting point to resist movements. Subjects were instructed to move the virtual point mass as fast as possible through suitable hand motions, so that the mass ends up and stops on the 'target' area.

Physioassistant: Sensorimotor training

Device

Subjects in the Sensorimotor training arm had to perform fast-and-accurate reaching movements in different directions. The manipulandum was only used to record hand movements, but throughout the movement it generated no forces.

Primary outcomes

  1. Change of the 9 Hole Peg Test score

    Time frame: baseline and 4 weeks and baseline and 16 weeks

Secondary outcomes

  1. Treatment change in percentage of responders at 9 Hole Peg Test score

    Time frame: baseline and 4 weeks and baseline and 16 weeks

    Number of responders i.e. the subjects who experienced an improvement greater than 20% at the 9HPT

  2. Absolute change of exercise performance

    Time frame: baseline and 4 weeks and baseline and 16 weeks

    Performance score (a combination of a movement duration and a path length component, with equal weights)

  3. Absolute change of task difficulty

    Time frame: baseline and 4 weeks and baseline and 16 weeks

    Resistive and mass-spring stiffness (Haptic group only)

Sponsors and collaborators

Lead sponsor

Fondazione Don Carlo Gnocchi ETS

Other

Collaborators

  • Azienda Sanitaria Locale 3 Genovese
  • University of Genova

Registry information

Official study title

Robot-based Assessment and Therapy in the Treatment of Upper Limb Impairment in Multiple Sclerosis: a Multi-center, Randomised Controlled Trial

Acronym: MS-ROBOT

Important dates

Study start
2010
Primary completion
2011
Study completion
2011
First posted
Mar 17, 2016
Registry last updated
Mar 17, 2016

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.