Rivanna Ultrasound for Neuraxial Block

We hypothesize that the Rivanna Accuro or similar U/S device would reduce time to success of identifying epidural and/or intrathecal spaces as compared to conventional palpation method.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–50 year

Sex eligibility

Female

Study type

Interventional

Phase

Not applicable

Primary location

Novant Health Forsyth Medical Center

Winston-Salem, North Carolina, 27103, United States

About this study

Administration of (neuraxial blocks) spinal and epidural blocks is commonly achieved by first palpating the landmarks for midline with spinous process and iliac crest for L3-4-5 intervertebral spaces. With an epidural block, a loss of resistance in a pressurized syringe is used to incrementally advance the epidural needle until identification of epidural space with loss of resistance in the pressurized syringe. With a spinal block, the spinal needle is advanced incrementally until a noted "feel" of dural puncture together with return of spinal fluid via the spinal needle. The palpation technique and somewhat "blind" technique to identify the spinal and epidural spaces become more difficult and less reliable particularly with the increasing prevalence of the morbid and super-morbid obese patients. Ultrasound devices have become common and successful with non-neuraxial blocks and venous accesses, both involving mostly non-bony, soft tissues. Application of conventional ultrasound for neuraxial blocks has been limited by its bulkiness, limited imaging for bony structures and lack of automated artificial intelligent algorithm for pattern recognition. Recent technological advancement has addressed the aforementioned limitations. Rivanna Accuro is one such device that has gained FDA approval and may have helped in addressing some of these issues. It is a handheld (pocket size) U/S device with real time pattern recognition for bony structures such as the spine while providing 3-D overlay for recognition of the midline spinous process and epidural spaces and distance. The investigators hypothesize that the Rivanna Accuro or similar U/S device would reduce time to success of identifying epidural and/or intrathecal spaces as compared to conventional palpation method. We will compare placement of neuraxial block between palpation method versus ultrasound method. We will compare placement of spinal block for cesarean delivery with palpation versus with ultrasound method, and then comparing placement of neuraxial analgeisa block (combined spinal epidural analgesia) for labor analgesia with palpation versus ultrasound method.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • BMI >30
  • Female requesting analgesia for delivery, be it via vaginal or cesarean delivery

Exclusion criteria

  • Allergy to ultrasound gel
  • Contraindication to receiving neuraxial analgesia
  • Under the age of 18

Treatment and study plan

Rivanna Accuro US Device

Device

When the subject is ready for neuraxial procedure, the location for the epidural or spinal needle insertion will be identified with Rivanna Accuro U/S device. For subjects in group C-R or L-R, the needle insertion site will be the site identified by the Rivanna Accuro U/S device. After placement of spinal for Cesarean or epidural for labor, the usual standard dose of medication will be administered as in usual manner for patients regardless in this study or not.

Palpation

Other

When the subject is ready for neuraxial procedure, the location for the epidural or spinal needle insertion will be identified with Palpation method using conventional landmarks (spinous process and iliac crest). For subjects in group C-P or L-P, the needle insertion site will be the site identified by the Palpation method. After placement of spinal for Cesarean or epidural for labor, the usual standard dose of medication will be administered as in usual manner for patients regardless in this study or not.

Neuraxial Analgesia

Procedure

Labor analgesia will be provided utilizing the standard medications to provide labor analgesia

spinal block

Procedure

Spinal anesthetic medications will be utilized in providing surgical block for cesarean delivery as is standard of care

Primary outcomes

  1. Time to Success of Neuraxial Block Placement

    Time frame: 60-225 seconds

    Time it takes to successfully identify the epidural space (defined by loss of resistance) for the groups of subjects receiving labor neuraxial analgesia; and spinal fluid flow into the hub of spinal needle for the groups of subjects receiving cesarean spinal anesthetic - length of time (in minutes) it takes to get block placed, between palpation and ultrasound groups among patients with labor neuraxial analgesia patients and cesarean spinal anesthetic, respectively and spinal fluid flow with spinal needle - length of time (in seconds) it takes to get block placed, between the 2 groups.

Secondary outcomes

  1. Total Number of Needle Passes Per Placement

    Time frame: 1 hour

    Number of needle Passes before successful placement

  2. Needle Passing Success at First Attempt

    Time frame: 1 hour

    Number of times of success (Number of patients) with first (single) attempt needle pass success

Sponsors and collaborators

Lead sponsor

Wake Forest University Health Sciences

Other

Registry information

Official study title

Evaluation of Success in Neuraxial Block Placement Between Using Palpation of Landmark Versus Pocket-Size Handheld Ultrasound (U/S) Method

Important dates

Study start
2017
Primary completion
2019
Study completion
2019
First posted
Jul 11, 2017
Registry last updated
Jul 28, 2021

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.