MECC system with rheoparin coating
DeviceMECC system for extracorporeal circulation equipped with rheoparin coating.
NCT Number: NCT02321917
In this study, the investigators would like to compare a heparin-coated tubing system for minimized extracorporeal circulation (MECC) with the conventional tubing system for MECC, which does not contain heparin coating. The MECC system has been used since 14 years in the investigators' hospital as an extracorporeal system to support circulation and provide oxygen to the tissues during coronary artery bypass grafting. Until today, the investigators performed more than 5000 MECC procedures in their department.
Looking for future studies?
Notify Me18 year–80 year
All sexes
Interventional
Not applicable
Dep. Cardiovascular Surgery, Bern, Switzerland
Background
The investigators would like to investigate a new composition of their MECC system in patients receiving coronary artery bypass surgery. Normally, the MECC system induces complement system activation and coagulation cascade, which could have a negative impact on postoperative outcome. A tubing system containing heparin (rheoparin) could contribute to a better biocompatibility in terms of a diminished activation of inflammatory reactions and a reduction of cerebral embolic load, which is a regular issue during extracorporeal circulation due to formation of solid and gaseous microemboli in the tubing system.
Objective
The aim is to investigate biocompatibility (coagulation, inflammation) and influence on cerebral embolic load of the rheoparin-coated MECC system and to compare the results with the current MECC system containing a rheoparin-free tubing system.
Methods
Patients undergoing elective coronary artery surgery are randomized to receive extracorporeal circulation using the MECC system with or without rheoparin coating. All procedures are performed according to the institutional standards.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
MECC system for extracorporeal circulation equipped with rheoparin coating.
Time frame: Perioperative period, 7 days
Biocompatibility will be assessed by measuring different coagulatory and inflammatory parameters as determined in comparable studies. Especially, hte investigators assess in their central laboratory the thrombin-antithrombin complex and the d-dimer as measures of the activity of the coagulation/fibrinolysis system and furthermore the complement factors C3a-C5a, the interleukins IL 6, IL8, IL10, the tumor-necrosis factor alpha (TNF-alpha), platelet factor 4 and the syndecan-1 activity as an expression of the inflammatory response to the different coating used for minimized extracorporeal circulation system.
Time frame: Perioperative period, 7 days
Time frame: At 30 days
Insel Gruppe AG, University Hospital Bern
Other
Coagulation, Inflammation and Cerebral Embolism Using a Rheoparin-coated Tubing System for Minimized Extracorporeal Circulation (MECC): Differences to the Conventional MECC System
Acronym: RheoMECC
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT00657475
Cardiac Surgery, Extracorporeal Circulation
Bordeaux, France
View Trial DetailsNCT06612060
Cardiac Surgery Requiring Cardiopulmonary Bypass, Cardiovascular Diseases
Thessaloniki, Greece
View Trial DetailsNCT02308566
Aortic Valve Disease, Aortic Valve Stenosis
Bern, Switzerland
View Trial DetailsNCT05875272
Cardio-pulmonary Bypass, Extracorporeal Circulation
Amiens, France
View Trial Details