Abnormal heart rhythms or arrhythmias are often managed by a procedure in which a catheter is introduced into the heart. These catheters can then cauterize abnormally functioning portions of the heart muscle with the hope of returning the heart to a more effective rhythm. In the process of performing such a procedure, called a catheter ablation, an operator must be able to accurately sense electrical activity displayed on computer screens in different parts of the heart, provide sufficient localized energy to the abnormally behaving tissue (ideally without damaging uninvolved heart structures), and accurately reassess the electrical activity of the heart to ensure the spot in the heart has been cauterized.
When sensing electrical activity of the heart, specialized catheters produce recordings on a computer screen known as electrograms (EGM). To produce this recording conventional catheters commonly use a positive and negative electrode, from which the difference between the two provides the EGM. The distance between the two electrodes varies from device to device. The greater the distance between them, the less accurate the measurement of local electrical activity becomes. This may result in poorly localized or excessive use of energy that could be damaging to normal heart structures or put the patient at risk for the return or development of additional arrhythmias. The IntellaTip MiFi catheter has been constructed with a specialized sensing tip that uses "microelectrodes" that are relatively close in proximity (<1 mm apart) with the hope of improving the sensing capability of the device.
This study will analyze the signals obtained from this FDA-approved catheter in people undergoing a catheter ablation procedure. The study will examine signals after the procedure is finished and will not prolong or differ the process from a standard ablation procedure. The goal of this study is to determine the ability of the microelectrodes to distinguish ablated, or cauterized versus non-cauterized tissue.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Atlanta, Georgia, 30322, United States
This trial is an operator-blinded, acute, single-visit observational trial in humans. Enrollment will include 25 patients undergoing a radiofrequency ablation procedure in which ablation of the cavotricuspid isthmus is planned. Electrogram characteristics of the small, imbedded pin electrodes will be compared to standard bipolar EGMs utilizing the ablation tip electrode and ring. Absolute voltage, voltage reduction, and frequency spectra will be examined before, during, and after ablation. EGM characteristics of standard and "ultra-local" recordings will be compared in their ability to accurately identify an effective RF lesion as defined below.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
-
This is observational trial studying the effects of a standard intervention of a catheter ablation procedure.
Other names: 8mm IntellaTip MiFi XP ablation catheter
Time frame: Acute, averaged one hour during ablation. Measured postoperatively.
Time frame: Acute, averaged one hour during ablation. Measured postoperatively
Emory University
Other
Radiofrequency Ablation Lesion Monitoring Using Imbedded Micro-Electrodes Versus Standard Bipolar Electrograms
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04096781
Arrhythmia, Arrhythmias, Cardiac
Palo Alto, California, United States
View Trial DetailsNCT03365440
Arrhythmia, Arrhythmias, Cardiac
Bern, Canton of Bern, Switzerland
View Trial DetailsNCT00313443
Arrhythmia, Arrhythmias, Cardiac
Paris, France
View Trial DetailsNCT07501299
Arrhythmia, Arrhythmias, Cardiac
Pittsburgh, Pennsylvania, United States
View Trial Details