Review of Efficacy of Used ultraSonic Energy Device

Single-use medical instruments are intended by the manufacturers for single-use only or for single-patient-use only. Nevertheless, single-use instruments are being reused more than once in many countries around the world. The reasons are mainly economic in developing countries and environmental in developed countries. Concerns are being raised regarding reused instruments sterility and efficacy. Since there is paucity of evidence on safety of multiple use of single-use instruments in surgery, we decided to conduct a clinical study comparing the same surgical procedure performed with new versus reused surgical instrument. We decided to study laparoscopic appendectomy which is a simple and the most common emergency surgery. Instrument under the scrutiny is ultrasonic scalpel which uses high-frequency ultrasound vibration for coagulating and cutting tissue. In the studied period of time, all eligible patients with acute appendicitis will be randomized in two groups, first having surgery with new device and the second having surgery with reused device. Removed appendix will be analyzed for lateral thermal damage and the patients will be followed-up for one month for potential differences in clinical outcomes like pain-killers consumption, length of stay and postoperative complications.

Completed

Looking for future studies?

Notify Me

Key information

Age range

5 year–65 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Clinical Hospital Split, Split, Croatia

Loading trial locations.

About this study

Laparoscopic appendectomy provides enhanced recovery at increased costs due to a need for a specific sophisticated equipment. Currently many of the commonly used devices are labeled by manufacturers as single-use only. This trend has stronghold in concerns about patient safety, especially about prevention of cross-infections and other safety-related issues. On the other hand, surgery costs are increased exponentially. There is paucity of evidence on safety of reusing single-use devices (SUD) in surgery. Reuse of SUD which may include refurbishing or reprocessing and resterilization is a complex issue with moral, technical, economical and environmental repercussions. There are several papers discussing the ethical dilemmas involved. The reprocessed instruments are generally deemed equally safe as new one. However there are only few experimental and clinical studies on this topic. Most of them are influenced by sponsors or manufacturers and therefore biased. What's more their conclusions are sometimes highly controversial. Goal of this study is to provide solid evidence on safety of reuse of SUD and to discover differences in in-vitro and clinical outcomes. One of the most common SUD for laparoscopic surgery is ultrasonic scalpel which uses high-frequency jaw vibration which simultaneously coagulates and divides structures with minimal thermal damage to surrounding tissue. One of the best known ultrasonic shears intended for single-use is harmonic scalpel (Ultracision® Ethicon EndoSurgery, Johnson&Johnson Company). Ultrasonic shears are being refurbished and/or resterilized for repetitive use in limited number of cycles or until become dysfunctional or disintegrate. Routine depends on local regulations and variations in practice. To encourage or to ban aforementioned practice we need solid evidence based on properly conducted clinical trial. Therefore we have designed a single-blind randomised clinical trial depending on virginity of instrument used for tissue dissection. Since Ultracision device is the most commonly used ultrasonic sealing device we decided to study outcomes of surgery performed with the new (unused) instrument versus resterilized reused instrument.

All of the patients with clinical and radiological suspicion of having acute appendicitis will be blindly allocated in two arms according to the predefined random sequence provided by independent statistician. Eligible patients will sign an informed consent form. First arm will have laparoscopic appendectomy with new ultrasonic device. The patient will be blinded for the allocation, but the surgeon can not be blinded since packing of the new and reused instruments differ. Even if the scrub nurse would give surgeon instruments without packing, some minor damage might be seen on the plastic coating of the instrument jaws. The second arm will have laparoscopic appendectomy with reused ultrasonic device. All other treatment including surgical technique, postoperative management and follow-up will be unchanged or within the standard of care. Surgical technique is standardised three-trocar approach in general anesthesia. All other details of the surgery are variable depending on local findings, extent of inflammation, anatomy variations etc. Removed specimens will be analyzed routinely with addition of measurement of lateral thermal damage of mesoappendix and appendiceal base. Patients will be screened for antibiotic therapy length, analgesics consumption, early surgical complications according to Clavien-Dindo classification and length of stay. Additionally one month follow-up will be conducted to pick-up possible late complications or readmissions. Study will be conducted in two centers for a period of time until sufficient number of participants are recruited.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Clinical diagnosis of acute appendicitis confirmed during surgery
  • Laparoscopic appendectomy
  • Operated with UltraCision harmonic scalpel.

Exclusion criteria

  • Finding of innocent (white) appendix
  • Pregnancy
  • Significant co-morbidity (ASA III-IV)
  • Open appendectomy
  • Laparoscopic appendectomy using instruments other than Ultracision harmonic scalpel.

Treatment and study plan

New Device

Device

Laparoscopic appendectomy using new ultrasonic shears.

Used Device

Device

Laparoscopic appendectomy using reprocessed ultrasonic shears.

Primary outcomes

  1. Lateral Thermal Damage of Mesoappendix

    Time frame: Through study completion, an average of 1 year.

    Microscopically measured distance of lateral thermal damage of mesoappendix

  2. Lateral Thermal Damage of Appendiceal Base

    Time frame: Through study completion, an average of 1 year.

    Microscopically measured distance of lateral thermal damage of appendiceal base

Secondary outcomes

  1. Clinical outcome - Postoperative complications

    Time frame: Postoperative 30 days follow-up

    Clavien Dindo classification of postoperative complications

  2. Clinical outcome - Length of stay

    Time frame: Through study completion, an average of 1 year.

    In-hospital stay in days

  3. Time to transect appendiceal base

    Time frame: During the surgery

    Speed of transection of appendiceal base regarding its diameter in seconds

  4. Rating Device Functionality

    Time frame: Immediately after surgery

    Rating of Surgeon's satisfaction with ultrasonic shears' performance using Performance Evaluation Scale (PES) where: 1 is unacceptable, 2 is acceptable, 3 is optimal.

    PES has 5 categories: 1. Hemostasis, 2. Coagulation effect, 3. Cutting effect, 4. Instrument activation force, 5. Disturbing sounds.

Sponsors and collaborators

Lead sponsor

University of Split, School of Medicine

Other

Collaborators

  • General Hospital Zadar
  • University Hospital of Split

Registry information

Official study title

Comparison of Lateral Thermal Damage and Clinical Outcomes of Laparoscopic Appendectomy With New Versus Reused Ultrasonic Scalpel in Patients With Acute Appendicitis - Randomized Clinical Trial

Acronym: REUSED

Important dates

Study start
2019
Primary completion
2020
Study completion
2020
First posted
Jan 13, 2020
Registry last updated
May 18, 2020

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.