Yedikule Chest Disease Hospital
Istanbul, Zeytinburnu, 34200, Turkey (Türkiye)
Location status: Recruiting
NCT Number: NCT06217276
In our study, changes in vastus lateralis muscle oxygenation will be evaluated with the Moxy device, a functional infrared oxygen measurement device, during the inspiratory muscle fatigue protocol in COPD cases and the healthy control group.
Interested in participating?
Request Info18 year–75 year
All sexes
Interventional
Not applicable
Istanbul, Zeytinburnu, 34200, Turkey (Türkiye)
Location status: Recruiting
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Inclusion criteria
for Healthy Cases
It will be performed using a powerbreath device at 60% of the maximum inspiratory pressure (MIP) amount obtained by measuring mouth pressure. The protocol includes 7 sets consisting of 2 minutes of inspiratory effort and 1 minute of rest. To further confirm the occurrence of fatigue, the patient will score fatigue using the modified Borg scale, and the score will be 5 or above11. During the application, heart rate, blood pressure and peripheral oxygen saturation will be monitored. The measurement will be performed once for each case.
Time frame: 20 minutes
Near Infrared Reflection Spectroscopy device will be used. The device measures and monitors muscle oxygen by taking the reflected rays of infrared rays given to the body from two different sensors to measure muscle oxygenation levels in muscle tissue. The measurement will be made in the dominant lower extremity, and the device will be placed in the mid-thigh region at the distance between the spina iliaca anterior superior reference point and the midpoint of the patella.
Time frame: 20 minutes
Near Infrared Reflection Spectroscopy device will be used. The device measures and monitors muscle total hemoglobin amount by taking the reflected rays of infrared rays given to the body from two different sensors to measure muscle oxygenation levels in muscle tissue. The measurement will be made in the dominant lower extremity, and the device will be placed in the mid-thigh region at the distance between the spina iliaca anterior superior reference point and the midpoint of the patella.
Time frame: 20 minutes
During the fatigue protocol, it will be measured with a finger pulse oximeter attached to the finger
Time frame: 5 minutes
Pulmonary function test will perform by using the Pony Fx spirometry device, and according to the American Thoracic Society (ATS) guidelines. FVC is the volume of air that can forcibly be blown out after full inspiration.
Time frame: 10 minutes
The mouth pressure measurement (maximum inspiratory and expiratory pressure) will perform with the Pony Fx spirometry device. Patient will place a rubber mouthpiece with flanges, on the device, exhale/inhale slowly and completely, and then will try to breath in as hard as possible. The patient will allow to rest for about a minute and the maneuver will repeat. The aim is that the variability between measurements is less than 10 cm H2O. The maximum value will obtain.
Time frame: 5 minutes
Pulmonary function test will perform by using the Pony Fx spirometry device, and according to the American Thoracic Society (ATS) guidelines. FEV1 is the volume of air that can forcibly be blown out in first 1-second, after full inspiration
Contact information is provided by the study sponsor or research team.
Istanbul Medipol University Hospital
Other
Examining the Relationship Between Respiratory Muscle Fatigue and Lower Extremity Muscle Oxygenation in Chronic Obstructive Pulmonary Disease Patients.
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07404826
COPD, Chronic Disease
Cincinnati, Ohio, United States
View Trial DetailsNCT06935825
COPD, Chronic Disease
Amsterdam, Netherlands
View Trial DetailsNCT07566195
COPD, Chronic Disease
Aix-en-Provence, France
View Trial DetailsNCT07567872
COPD, Chronic Disease
Chengdu, Sichuan, China
View Trial Details