Hospital das Clínicas -HCFMUSP
São Paulo, 05403010, Brazil
NCT Number: NCT02687802
The objective of the study is to estimate the incidence of asynchrony and to assess its relationship with respiratory mechanics. This will be a prospective cohort study, including patients under invasive mechanical ventilation. Within 48h post intubation, the investigators will record the values of intrinsic positive end-expiratory pressure, pulmonary compliance and resistance. Participants will be followed up from intubation to mechanical ventilation liberation. The investigators will register clinical signs of asynchrony and record ventilator waveforms continuously and quantify patient-ventilator asynchrony. The investigators will calculate the total asynchrony index (AI) and of each asynchrony type (ineffective triggering, double triggering, auto triggering, short cycling and prolonged cycling). Participants will be followed up until hospital discharge.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
São Paulo, 05403010, Brazil
Patient-ventilator asynchrony is common in patients under invasive mechanical ventilation, present between 10 and 80% of all respiratory cycles, and is associated with adverse clinical outcomes, such as delay in the weaning process, increased complications of mechanical ventilation, with possible impact on survival. The objective of this study is to estimate the incidence of asynchrony and to assess its relationship with respiratory mechanics. This will be a prospective cohort study, including all patients under invasive mechanical ventilation admitted at Respiratory ICU at Hospital das Clínicas da Faculdade de Medicina da Universidade de Sao Paulo (USP), during the study period. Within 48h post intubation, the investigators will record the values of intrinsic positive end-expiratory pressure, pulmonary compliance and resistance. Participants will be followed up from intubation to mechanical ventilation liberation. The investigators will register clinical signs of asynchrony and record ventilator waveforms continuously. The ventilator waveforms will be captured directly from ventilator and processed by dedicated software, without direct contact with patients. Later, ventilator waveforms will be analyzed to quantify patient-ventilator asynchrony. The investigators will calculate the total asynchrony index (AI) and of each asynchrony type (ineffective triggering, double triggering, auto triggering, short cycling and prolonged cycling). Participants will be followed up until hospital discharge, and the investigators will record duration of mechanical ventilation, the use of non-invasive ventilation post-extubation, reintubation, tracheostomy, ICU and hospital length of stay and survival. With this project, the investigators will estimate the incidence and magnitude of patient-ventilator asynchrony and its association with clinical outcomes
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
we will measure static resistance, compliance and intrinsic positive end-expiratory pressure (PEEP) and other variables as risk factors for asynchrony occurrence
Time frame: from study inclusion until the date of extubation or date of death from any cause, whichever comes first, up to 28 days
asynchrony index will be calculated as the number of major asynchrony events divided by total number of respiratory cycles
Time frame: daily, from study inclusion until the date of extubation or date of death from any cause, whichever comes first, up to 28 days
a standardized questionnaire will be used to evaluate the presence of clinically significant patient-ventilator asynchrony. Trained investigators will observe participant´s breathing pattern and other clinical signs of patient-ventilator asynchrony and score each item as absent (0) or present (1). Then, they will visual inspection of ventilator waveforms on the ventilator screen for a 5 minute observation period, looking for missed efforts, double triggering, auto-triggering, cycling delay and premature cycling, as previously defined. If they observe more than 1 asynchrony event for every 10 respiratory cycles, they will rate this item as present (1), otherwise, they will rate it as absent (0).
Time frame: 28 days
number of days alive and off the ventilator up to day 28
Time frame: up to 90 days
performance of surgical or bronchoscopy-guided tracheotomy
Time frame: at 28 and 90 days
survival from intubation up to 90 days
University of Sao Paulo General Hospital
Other
Acronym: EpiSync
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07144878
Intensive Care Units, Pathologic Processes
Banhā, Egypt
View Trial DetailsNCT01376518
Acute Lung Injury, Lung Diseases
Mainz, Germany
View Trial DetailsNCT03827356
Fatigue, Pathologic Processes
Salamanca, Spain
View Trial DetailsNCT00638339
Dyssomnias, Mental Disorders
Boston, Massachusetts, United States
View Trial Details