This study is designed to be a clinical validation study to ready the CPM System for FDA 510(k) submission. This study will be conducted as a prospective non-randomized. The study is non-significant risk since the CPM Device is noninterventional and noninvasive. The study is primarily designed to validate the accuracy of the respiration rate and the changes in relative tidal volume. All participants will be fitted with both the CPM Device as well as reference devices (capnography and ECG). Participants will be randomized between 4 procedures (A-D) which will determine the order of 10 exercises. Each exercise has about 2 minutes of device recording and two minutes of rest. Each exercise contains two positions: sitting up for one minute and lying down for one minute. For some exercises, the participant will be instructed to breathe at a certain rate (assisted by a metronome). For other exercises, the participants will breathe at a normal rate but change how deep the are breathing. For the last, all capnography reference devices will be removed, and an ECG reference device will be placed. After exercise 18, the participant will have all devices removed and the study visit will terminate. The participant will receive a safety follow-up call about 1 week after their visit.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
St Louis, Missouri, 63123, United States
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The CPM device and reference device are used simultaneous to validate the CPM device.
Time frame: 90 minutes
Percentage of respiration rate error within ± 2bpm. Acceptance criteria for clinical utility is >= 85%. The percentage of respiration rate within ± 2brpm was calculated by data points, regardless of its rate and breathing condition, which the CPM System did not screen, therefore reporting the numeric values. Each data point will produce binary result (True or False) if the error is within ± 2 brpm. Assuming this binary result follows a binominal distribution, its confidence interval is also calculated.
Time frame: 90 minutes
First, the subject-specific linear fitting is performed after taking the natural log of both CPM's rTV and reference TV. Then, the residual errors in rTV after the fitting were calculated. Finally, all subject's residual errors are pooled together to calculate the root mean squared (RMS) residual relative errors. The confidence interval was calculated assuming the square of this error follows Chi-square distribution. This error characterized in a log-log domain is converted back to characterize a relative accuracy by taking an exponential of natural constant followed by subtraction of one. The RMS of residual error in % is characterized in this way because the linear fitting in the log-log domain and its residual errors represents faithful relative residual error regardless of an absolute value of TV.
Time frame: device measurement (3 minutes)
Performance of CPM System's ECG is measurement by comparing CPM System ECG metrics to the reference device Lead II ECG strip. Clinicians reviewed the criteria below and decided if the CPM strip had equivalence to the Lead II strip.
Time frame: device measurement (3 minutes)
Determine the accuracy of CPM System's ECG metrics to the reference device. Results are displayed as mean error with standard deviation of error.
Analog Device, Inc.
Other
Clinical Validation Study for Noninvasive Cardiopulmonary Management Device
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04863677
Cardiopulmonary Disease, Cardiovascular Diseases
Guangzhou, Guangdong, China
View Trial DetailsNCT04865640
Cardiopulmonary Disease, Cardiovascular Diseases
Rochester, Minnesota, United States
View Trial DetailsNCT03911856
Cardiopulmonary Disease, Cardiovascular Diseases
Rochester, Minnesota, United States
View Trial DetailsNCT05776264
Behavior, Cardiopulmonary Disease
New York, United States
View Trial Details