Affiliated Hospital of Jiangsu University
Zhenjiang, Jiangsu, China
NCT Number: NCT03471845
It is a single arm clinical evaluation of safety and efficacy of the Medtronic Resolute Onyx™ zotarolimus-eluting coronary stent system in subjects who are eligible for percutaneous transluminal coronary angioplasty (PTCA) in de novo lesions amenable to treatment with Resolute Onyx™ Stent System in China.
This study is active but is not currently recruiting participants.
18 year and older
All sexes
Interventional
Not applicable
Zhenjiang, Jiangsu, China
This study is a pre-Market, prospective, multi-center, single arm trial. Subjects will be enrolled and followed through 5 Years (screen, implant procedure(including post-procedure assessment),30-Day, 6 Months, 9 Months-subjects implanted with fringe size, and annual assessments from 1-5 years).
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Key Inclusion Criteria:
Key Exclusion Criteria:
Treatment of subjects eligible for percutaneous transluminal coronary angioplasty (PTCA) as per study requirements
Time frame: 12 months
TLF
Time frame: at the end of the index procedure or during hospital stay:estimated 7 days
Definition 1: The attainment of <50% residual stenosis of the target lesion using only the assigned device.
Definition 2: The attainment of < 30% residual stenosis by QCA (or < 20% by visual assessment) AND a TIMI flow 3 after the procedure, using the assigned device only. These measurements will be made by the independent angiographic core laboratory.
Time frame: at the end of the index procedure or during hospital stay: estimated 7 days
Definition 1: The attainment of <50% residual stenosis of the target lesion using any percutaneous method.
Definition 2: The attainment of < 30% residual stenosis by QCA (or < 20% by visual assessment) AND a TIMI flow 3 after the procedure, using any percutaneous method. These measurements will be made by the independent angiographic core laboratory. If the core laboratory is unable to assess the % residual stenosis, the Investigator's assessment as recorded in the CRF will be used for the statistical analysis.
Time frame: at the end of the index procedure or during hospital stay: estimated 7 days
Definition 1: The attainment of <50% residual stenosis of the target lesion and no in-hospital MACE.
Definition 2: The attainment of < 30% residual stenosis by QCA (or < 20% by visual assessment) AND a TIMI flow 3 after the procedure, using any percutaneous method without the occurrence of MACE during the hospital stay. These measurements will be made by the independent angiographic core laboratory. If the core laboratory is unable to assess the % residual stenosis, the Investigator's assessment as recorded in the CRF will be used for the statistical analysis.
Time frame: 30 day, 6 months, 9 months (if applicable), 1 year, 2 years,3 years, 4 years, 5 years
Defined as composite of death, myocardial infarction (Q wave and non-Q wave), or clinically-driven repeat target lesion revascularization by percutaneous or surgical methods
Time frame: 30 day, 6 months, 9 months (if applicable), 1 year, 2 years,3 years, 4 years, 5 years
All deaths
Time frame: 30 day, 6 months, 9 months (if applicable), 1 year, 2 years,3 years, 4 years, 5 years
All myocardial infarction data will be reported per Medtronic historical protocol definitions.
Time frame: 30 day, 6 months, 9 months (if applicable), 1 year, 2 years,3 years, 4 years, 5 years
Combined endpoints including Target Legion Revascularization (TLR), Target Vessel Revascularization (TVR) and Non-TVR
Time frame: 30 day, 6 months, 9 months (if applicable), 1 year, 2 years,3 years, 4 years, 5 years
TVF
Time frame: 30 day, 6 months, 9 months (if applicable), 1 year, 2 years,3 years, 4 years, 5 years
TLF
Time frame: 30 day, 6 months, 9 months (if applicable), 1 year, 2 years,3 years, 4 years, 5 years
ST
Time frame: 9 months
Only for subjects implanted with certain stent sizes: Angiographic measures: In-stent and In-segment late luminal loss
Time frame: 9 months
Only for subjects implanted with certain stent sizes: Angiographic measures: In-stent and In-segment late luminal loss
Time frame: 9 months
Only for subjects implanted with certain stent sizes: Angiographic measures: In-stent and in-segment percent diameter stenosis (%DS)
Time frame: 9 months
Only for subjects implanted with certain stent sizes: Angiographic measures: In-stent and in-segment binary restenosis rate
Time frame: 9 months
Only for subjects implanted with certain stent sizes: Angiographic measures:In-stent and in-segment minimal luminal diameter (MLD)
Medtronic Vascular
Industry
A Single Arm Clinical Evaluation of Safety and Efficacy of the Medtronic Resolute Onyx™ Zotarolimus-Eluting Coronary Stent System in the Treatment of Subjects Eligible for Percutaneous Transluminal Coronary Angioplasty (PTCA) in China
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03466151
Arterial Occlusive Diseases, Arteriosclerosis
Shenyang, Liaoning, China
View Trial DetailsNCT03118531
Arterial Occlusive Diseases, Arteriosclerosis
Beijing, Beijing Municipality, China
View Trial DetailsNCT01243749
Arterial Occlusive Diseases, Arteriosclerosis
Beijing, China
View Trial DetailsNCT01334268
Arterial Occlusive Diseases, Arteriosclerosis
Beijing, Beijing Municipality, China
View Trial Details