NCT Number: NCT01132456

RESOLUTE Asia: Evaluation of the Endeavor Resolute Zotarolimus-Eluting Stent System in a Patient Population With Long Lesion(s) and/or Dual Vessels in Asia

The purpose of this study is to document the safety and overall clinical performance of the Endeavor Resolute Zotarolimus-Eluting Coronary Stent System in a patient population with long lesion(s) and/or dual vessels requiring stent implantation.

Completed

Looking for future studies?

Notify Me

Key information

About this study

A total of 249 to 411 patients will be enrolled from Asia at approximately 25 centers where Endeavor Resolute stent is commercially available. There are two study cohorts:

  • 38 mm cohort: a minimum of 46 patients and maximum of 111 patients with at least one lesion amenable to treatment with a 38 mm length Endeavor Resolute stent. Patients may have one or two lesions, if the two lesions are located in separate target vessels.
  • Dual vessel cohort: a minimum of 203 patients and maximum of 300 patients with dual vessel treatment where each vessel has a lesion with length ≤ 27 mm and reference vessel diameters between 2.25 mm and 4.0 mm.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Acceptable candidate for percutaneous coronary intervention (PCI),stenting, and emergency coronary artery bypass graft surgery
  • Clinical evidence of ischemic heart disease, stable or unstable angina, silent ischemia and/or positive functional study
  • Informed consent
  • Patient agrees to comply with specified follow-up evaluations at same investigational site
  • Single target lesion or two target lesions located in separate coronary arteries
  • De novo lesion(s) in native coronary artery(ies)
  • Target lesion(s) ≤ 35 mm in length (or both lesion lengths ≤ 27 mm for two lesions in separate target vessels to be considered for the dual vessel cohort)
  • Target vessel(s) have reference vessel diameter 2.25 mm to 4.0 mm, (or 3.0 to 4.0 mm for it to be treated with a 38 mm length stent)

Exclusion criteria

  • Within 7 days of implant platelet count <100,000 cells/mm³ or >700,000 cells/mm³; WBC count <3,000 cells/mm³; serum creatinine level >2.5 mg/dl
  • Acute MI within 72 hrs of the index procedure (QWMI or any elevation of CK-MB > lab upper limit of normal)
  • Previous PCI of target vessel(s) within 9 months prior to the procedure
  • Planned PCI of any vessel within 30 days post-index procedure and/or planned PCI of target vessel(s) within 12 months post-index procedure
  • History of stroke or TIA within prior 6 months
  • Participating in investigational drug/device study that has not completed primary endpoint or interferes with study endpoints
  • Inability to comply with required trial antiplatelet regimen
  • Previous stent in target vessel unless it has been at least 9 months since stent placed and target lesion(s) is/are at least 15 mm from previous stent
  • Target vessel(s) has/have other lesions w/ > 40% diameter stenosis
  • Unprotected left main coronary artery disease

Treatment and study plan

Drug eluting stent treatment

Device

Endeavor RESOLUTE Zotarolimus-Eluting Coronary Stent Implantation

Primary outcomes

  1. Target Lesion Failure (TLF) for 38mm cohort and Target Vessel Failure (TVF) for dual vessel cohort

    Time frame: 12 months

    TLF is defined as composite of cardiac death, target vessel myocardial infarction (Q wave and non-Q wave) or clinically-driven target lesion revascularization (TLR) by percutaneous or surgical methods. TVF is defined as composite of cardiac death, target vessel myocardial infarction (Q wave and non-Q wave) or clinically-driven target vessel revascularization (TVR).

Secondary outcomes

  1. Death

    Time frame: 30d, 6m, 9m, 12m, 18m, 2yr, 3yr

    Death rate in the study.

  2. MI

    Time frame: 30d, 6m, 9m, 12m, 18m, 2yr, 3yr

    Myocardial infarction (MI) rate in the study.

  3. Cardiac death and MI

    Time frame: 30d, 6m, 9m, 12m, 18m, 2yr, 3yr

    Cardiac death and myocardial infarction (MI) rate in the study

  4. MACE

    Time frame: 30d, 6m, 9m, 12m, 18m, 2yr, 3yr

    MACE composite endpoint and each individual component (death, myocardial infarction (MI) (Q wave and non-Q wave), emergent coronary bypass surgery (CABG), or clinically-driven repeat target lesion revascularization by percutaneous or surgical methods)

  5. TLF

    Time frame: For 38mm cohort it is 30d, 6m, 9m, 18m, 2yr and 3yr. For dual vessel cohort it is 30d, 6m, 9m, 12m, 18m, 2yr and 3yr

    TLF composite endpoint and each individual component (cardiac death, target vessel MI or clinically-driven TLR)

Sponsors and collaborators

Lead sponsor

Medtronic Vascular

Industry

Registry information

Official study title

RESOLUTE Asia: Evaluation of the Endeavor Resolute Zotarolimus-Eluting Coronary Stent System in a Patient Population With Long Lesion(s) and/or Dual Vessels in Asia

Acronym: R-A

Important dates

Study start
2010
Primary completion
2013
Study completion
2016
First posted
May 28, 2010
Registry last updated
Jun 13, 2016

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.