NCT Number: NCT02868957

Repetition Improves Precision and Trueness of Digital Intraoral Scans

The objectives of this study were to compare the precision of two digital intraoral scanners from a series of repeat scan images, and to investigate the effect of the learning curve on changes in trueness when scanning the full arch of the oral cavity in actual patients.

Completed

Looking for future studies?

Notify Me

Key information

Age range

20 year–35 year

Sex eligibility

Female

Study type

Interventional

Phase

Not applicable

Primary location

Seoul National University Gwanak Dental Hospital

Seoul, 08826, South Korea

About this study

Study Participants: This study was approved by the institutional review board of Ehwa Womans University Medical Center Mokdong Hospital, and dental hygienists who were suitable for the purpose of the study were selected (ECT14-02A-27). Participants were assigned one of four patients, and subsequently scanned the oral cavity of a single patient 10 times repeatedly over 4 days.

Study Design: The participants visited the dental clinic and performed scanning for 4 days. In order to investigate the difference in the precision and trueness of two types of intraoral scanners, the participants scanned the dental arch of a single patient 10 times using an assigned digital intraoral scanner. On the first day, either of the two types of scanners (iTero and Trios), and a patient were assigned. Then, the participants were trained in theory and practices of the assigned scanner, and subsequently, using it, scanned the dental arch of the assigned patient twice. On the second and third days, the dental arch of the same patient was scanned 3 times respectively, and on the fourth day, the experiment was finished after scanning the same patient twice.

Statistical Analyses: Collected data were analyzed using the SPSS Ver. 20.0 statistical package. For the determination of differences in the deviations according to the scanner, the independent two-sample t-test was conducted to examine the significance of the precision data. For comparisons of trueness according to repeated learning, the repeated measure ANOVA was used to test for differences between the scanners, clinical experience of the participants, and the scanning region within the same scanner group. The significance of time-dependent changes, and the interaction between the scanner group and time variables, were examined by within-subject tests. Differences between the scanner groups were examined by between-subject tests. The significance of the 10 consecutive scans and four visits within the scanner group, and the difference between the scanner groups at each time point, were examined by the post-hoc test, which was performed using the Bonferroni method as a multiple comparison (α= 0.05).

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • The selection criteria for the participants were as follows: they had the clinical experiences between 3 - 11 years, understood the purpose of the study well, gave their consent, and were able to carry out a 4-day learning course. Those who were inadequate to carry out the study mentally or physically.

Exclusion criteria

  • Applicant who was considered inappropriate .for this study by the principal investigator was excluded from the selection

Treatment and study plan

impression data from reference scanner

Other

To create a reference images for the assessment of the trueness, the impressions of the upper and lower arch of the oral cavities of four patients were taken using a polyether impression material (3M ESPE Soft Monophase; Minnesota Mining and Manufacturing Co.), and the intaglio scanning was performed on the impression body using a desktop scanner. Scanned images were transformed to the Standard Tessellation Language (STL) file format, and used as reference images.

iTero

Device

The participants visited the dental clinic and performed scanning for 4 days. In order to investigate the difference in the precision and trueness of iTero intraoral scanners, the participants scanned the dental arch of a single patient 10 times using an assigned digital intraoral scanner.

Trios

Device

The participants visited the dental clinic and performed scanning for 4 days. In order to investigate the difference in the precision and trueness of Trios intraoral scanners, the participants scanned the dental arch of a single patient 10 times using an assigned digital intraoral scanner. .

Primary outcomes

  1. Precision and trueness of intraoral scanners after repeated scanning practice assessed by Geomagic Verify Ver.20152.0

    Time frame: One year

    Assessment was done by registering pairs of scan images and calculating deviation by computer calculation in micrometers.

Secondary outcomes

  1. Scan time required for full arch image acquisition in seconds

    Time frame: up to one year

    Scan time was measured until the scanned image was satisfactory with reference to the standard quality by one inspector.

Sponsors and collaborators

Lead sponsor

Seoul National University Gwanak Dental Hospital

Other

Registry information

Official study title

Standardization of Evaluation Protocol for the Performance Comparison of Digital Intra-oral Scanners

Important dates

Study start
2014
Primary completion
2014
Study completion
2014
First posted
Aug 16, 2016
Registry last updated
Aug 16, 2016

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.