Repeatability and Agreement of Anterior Segment Optical Coherence Tomography (AS-OCT) and Thermography

Dry eye is a common condition that affects vision and quality of life in patients. Dry eye clinical research is limited to follow up of disease progression. Currently, most research outcomes are based on subjective patient complaints rather than objective assessment of the condition. Only few objective measurements for dry eye are available today and this is mainly the result of poor repeatability and inaccuracy.

This current study aims to evaluate 2 new non-invasive imaging techniques suitable for dry eye assessment.

Anterior segment optical coherence tomography (AS-OCT) is an imaging device that has the ability to image the tear meniscus of the eye in a safe and non-invasive manner. Image analysis can then indirectly determine the tear film volume. Improvements in the image resolution of these devices require a study that compares the repeatability and agreement of an older (Visante AS-OCT) and a newer instrument (Cirrus AS-OCT) which the current study aims to address.

Another method of evaluating dry eye disease is a novel technique that uses functional infrared thermography to measure tear evaporation rate. This study will also establish repeatability of measurements of the ocular surface temperature which are used to calculate tear evaporation rates.

Should these methods are found to be repeatable, they can be used in future clinical trials as an additional tool to investigate dry eye treatments.

Completed

Looking for future studies?

Notify Me

Key information

Age range

21 year–90 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Singapore Eye Research Institute

Singapore, 168751

About this study

Study Objectives and Purpose:

Part A - AS-OCT repeatability and agreement

  • The primary purpose of Part A is to compare the repeatability of the Cirrus with the Visante AS-OCT imaging system.
  • The second objective is to identify the level of agreement in the tear meniscus measurements taken by the Cirrus and Visante AS-OCT.

Part B - Tear evaporimetry with functional infra-red thermography

  • To evaluate the repeatability of Infrared thermography for ocular surface temperature measurements that are used for calculation of tear evaporation rates. If this is found to be acceptable, it will be correlated to tear meniscus parameters.
  • To determine whether this method is able to detect temperature changes of the ocular surface.

Study design:

Part A. Cross sectional study. Part B. Prospective study

Rationale:

Part A - AS-OCT repeatability and agreement Repeatability is an important issue in the objective assessment of dry eye. While previous studies have compared various methods of measuring the tear meniscus, including the use of Visante AS-OCT, current literature lacks studies that investigated the Cirrus AS-OCT for assessment of dry eye. With a higher resolution, the Cirrus is potentially useful as a non-invasive procedure for objective measurements of the tear meniscus.

Part B - Tear evaporimetry with functional infra-red thermography Current available methods to measure of tear evaporation rate have major limitations. This new method, however, is non-invasive, has no need for special eye drops or chambers and takes temperature measurements very quickly. This method is therefore extremely practical and provides many exciting possibilities for future trials.

Methods:

Participants and target sample size 40 volunteers from Singapore Eye Research Institute will be recruited for this study. Each volunteer will be given a study serial number to ensure anonymity.

20 will participate in the AS-OCT study. 20 will participate in the tear evaporimetry study.

Part A - AS-OCT repeatability and agreement Two AS-OCT imaging systems, namely Cirrus and the Visante, will be tested. All participants undergo acquisition of 2 images by the Visante AS-OCT, then 2 images by the Cirrus AS-OCT. Both images will be acquired by the same technician.

Part B - Tear evaporimetry with functional infra-red thermography In total, four pairs of thermographic sequences on the ocluar surface temperature from volunteers will be taken.

  • The volunteer will be seated in front of the thermographic camera and on each eye on thermographic sequence will be captured.
  • After 20 minutes, a second pair of thermographic sequences will be captured.
  • An eye mask with a temperature of not more than 40 deg C (confirmed by thermometer) will be worn by the volunteer for 5 minutes.
  • A third pair of thermographic sequences will be captured immediately after mask removal.
  • A fourth pair of thermographic sequences will be captured 1 hour after mask removal.

Between sequence acquisitions, the volunteer is allowed to move freely in the room. The temperature and humidity of the room will be kept constant during measurements.

Visit schedules:

Only one examination per ASOCT instrument for Part A is required. For Part B, all thermography will be performed on the same day.

If participants agree to have both ASOCT and tear evaporimetry done, then they will undergo Parts A and B. If not, they will be recruited for either Part A or Part B.

Duration of study: 1 day

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Volunteers that are medically fit and willing to participate in this study.

Exclusion criteria

  • No eye surgery done within the previous 3 months
  • Active ocular infection or pterygium that may affect tear film stability.
  • Any other specified reason as determined by clinical investigator.

Treatment and study plan

EyeGiene

Device

The eye mask with a temperature of not more than 40 deg C (confirmed by thermometer) will be worn by the volunteer for 5 minutes.

Other names: EyeGiene (Eyedetec Medical Inc., US)

Primary outcomes

  1. equipment repeatability

    Time frame: 1 day

    Part A - The repeatabilty coefficients of tear meniscus measurements derived from Visante and Cirrus AS-OCT and the agreement between tear meniscus measurements.

    Part B - Infrared thermography is expected to be repeatable in capturing OST measurements which will consequently result in repeatable tear evaporation rates. Temperature changes of the ocular surface will be adequately captured.

Secondary outcomes

  1. temperature changes

    Time frame: 1 day

    Determine whether thermogram images can capture changes in temperature/the rate of tear evaporation which were introduced by warm eye mask wear.

Sponsors and collaborators

Lead sponsor

Singapore National Eye Centre

Other Gov

Collaborators

  • Nanchang University
  • Singapore Eye Research Institute

Registry information

Official study title

Repeatability and Agreement of Visante and Cirrus Anterior Segment Optical Coherence Tomography and Functional Infrared Thermography

Important dates

Study start
2011
Primary completion
2012
Study completion
2012
First posted
Nov 24, 2011
Registry last updated
Feb 21, 2013

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.