Singapore Eye Research Institute
Singapore, 168751
NCT Number: NCT01479790
Dry eye is a common condition that affects vision and quality of life in patients. Dry eye clinical research is limited to follow up of disease progression. Currently, most research outcomes are based on subjective patient complaints rather than objective assessment of the condition. Only few objective measurements for dry eye are available today and this is mainly the result of poor repeatability and inaccuracy.
This current study aims to evaluate 2 new non-invasive imaging techniques suitable for dry eye assessment.
Anterior segment optical coherence tomography (AS-OCT) is an imaging device that has the ability to image the tear meniscus of the eye in a safe and non-invasive manner. Image analysis can then indirectly determine the tear film volume. Improvements in the image resolution of these devices require a study that compares the repeatability and agreement of an older (Visante AS-OCT) and a newer instrument (Cirrus AS-OCT) which the current study aims to address.
Another method of evaluating dry eye disease is a novel technique that uses functional infrared thermography to measure tear evaporation rate. This study will also establish repeatability of measurements of the ocular surface temperature which are used to calculate tear evaporation rates.
Should these methods are found to be repeatable, they can be used in future clinical trials as an additional tool to investigate dry eye treatments.
Looking for future studies?
Notify Me21 year–90 year
All sexes
Interventional
Not applicable
Singapore, 168751
Study Objectives and Purpose:
Part A - AS-OCT repeatability and agreement
Part B - Tear evaporimetry with functional infra-red thermography
Study design:
Part A. Cross sectional study. Part B. Prospective study
Rationale:
Part A - AS-OCT repeatability and agreement Repeatability is an important issue in the objective assessment of dry eye. While previous studies have compared various methods of measuring the tear meniscus, including the use of Visante AS-OCT, current literature lacks studies that investigated the Cirrus AS-OCT for assessment of dry eye. With a higher resolution, the Cirrus is potentially useful as a non-invasive procedure for objective measurements of the tear meniscus.
Part B - Tear evaporimetry with functional infra-red thermography Current available methods to measure of tear evaporation rate have major limitations. This new method, however, is non-invasive, has no need for special eye drops or chambers and takes temperature measurements very quickly. This method is therefore extremely practical and provides many exciting possibilities for future trials.
Methods:
Participants and target sample size 40 volunteers from Singapore Eye Research Institute will be recruited for this study. Each volunteer will be given a study serial number to ensure anonymity.
20 will participate in the AS-OCT study. 20 will participate in the tear evaporimetry study.
Part A - AS-OCT repeatability and agreement Two AS-OCT imaging systems, namely Cirrus and the Visante, will be tested. All participants undergo acquisition of 2 images by the Visante AS-OCT, then 2 images by the Cirrus AS-OCT. Both images will be acquired by the same technician.
Part B - Tear evaporimetry with functional infra-red thermography In total, four pairs of thermographic sequences on the ocluar surface temperature from volunteers will be taken.
Between sequence acquisitions, the volunteer is allowed to move freely in the room. The temperature and humidity of the room will be kept constant during measurements.
Visit schedules:
Only one examination per ASOCT instrument for Part A is required. For Part B, all thermography will be performed on the same day.
If participants agree to have both ASOCT and tear evaporimetry done, then they will undergo Parts A and B. If not, they will be recruited for either Part A or Part B.
Duration of study: 1 day
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The eye mask with a temperature of not more than 40 deg C (confirmed by thermometer) will be worn by the volunteer for 5 minutes.
Other names: EyeGiene (Eyedetec Medical Inc., US)
Time frame: 1 day
Part A - The repeatabilty coefficients of tear meniscus measurements derived from Visante and Cirrus AS-OCT and the agreement between tear meniscus measurements.
Part B - Infrared thermography is expected to be repeatable in capturing OST measurements which will consequently result in repeatable tear evaporation rates. Temperature changes of the ocular surface will be adequately captured.
Time frame: 1 day
Determine whether thermogram images can capture changes in temperature/the rate of tear evaporation which were introduced by warm eye mask wear.
Singapore National Eye Centre
Other Gov
Repeatability and Agreement of Visante and Cirrus Anterior Segment Optical Coherence Tomography and Functional Infrared Thermography
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05481450
Dry Eye, Dry Eye Syndromes
Lutz, Florida, United States
View Trial DetailsNCT06483750
Cataract Senile, Dry Eye Disease
Washington D.C., District of Columbia, United States
View Trial DetailsNCT07588074
Conjunctival Diseases, Conjunctivitis
Baton Rouge, Louisiana, United States
View Trial DetailsNCT04730336
Dry Eye, Dry Eye Syndromes
Solihull, United Kingdom
View Trial Details