BIA
OtherBioelectrical impedance analysis was performed within 4 days after a CT-scan was made
Other names: Bioelectrical impedance analysis
NCT Number: NCT02555670
Aim of the present study is to determine whether muscle mass as assessed by bioelectrical impedance analysis correlates with and corresponds to muscle mass as assessed by CT scan analysis in critically patients admitted to the intensive care unit.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
BIA measurements are performed in critically ill patients admitted to the ICU or MC, within 72 hours before or after CT scanning.
The BIA measurements are taken with the BIA 101 ASE, manufactured by Akern, Florence-7 Italy. This device is phase sensitive and injects an alternating current of 400 µA at 50 kHz. Measurements were performed while patients lay in supine position with a pillow supporting the head. The resistance, reactance, body weight and length are entered in the BIA algorithm, using BodyGram PRO. This algorithm calculated the body composition, with muscle mass being reported in kilogram (kg).
Abdominal CT scans are analyzed using the computer program SliceOmatic® version 4.3 and 5.0 (TomoVision, Montreal, QC, Canada) at the level of the third lumbar vertebra (L3). The muscle tissue was identified by using boundaries in Hounsfield Units (grayscale) set of -29 to +150(23). The program computes muscle surface area in cm2, by multiplying the pixel area by the amount of pixels identified as muscle.
For a direct comparison with the BIA-derived muscle mass, the CT-derived muscle area is converted to kg. This is done by following two steps. Firstly, the Shen equation is used for the conversion to litres.Secondly, the muscle volume is multiplied by its density, resulting in muscle mass expressed in kg.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Bioelectrical impedance analysis was performed within 4 days after a CT-scan was made
Other names: Bioelectrical impedance analysis
Time frame: Patient's data from the ICU-stay will be used, an average of one week
Agreement will be calculated using a Bland-Altman plot
Time frame: Patient's data from the ICU-stay will be used, an average of one week
Using CT-derived cut-off points, sensitivity of BIA to identify the same patients as having low muscle will be calculated
Time frame: Patient's data from the ICU-stay will be used, an average of one week
Using CT-derived cut-off points, specificity of BIA to identify the same patients as having low muscle will be calculated
Time frame: Patient's data from the ICU-stay will be used, an average of one week
Correlation will be calculated using Pearson's r
Amsterdam UMC, location VUmc
Other
Relation Between Bioelectrical Impedance-derived Muscle Mass and CT-derived Muscle Area in Critically Ill Patients
Acronym: ICUBIACT
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05156320
Anti-myostatin, Atrophy
Birmingham, Alabama, United States
View Trial DetailsNCT06233825
Anterior Cruciate Ligament Reconstruction, Atrophy
Kingston, Ontario, Canada
View Trial DetailsNCT02912130
Atrophy, Behavior
Liverpool, Merseyside, United Kingdom
View Trial DetailsNCT03921528
Atrophy, Central Nervous System Diseases
Phoenix, Arizona, United States
View Trial Details