The purpose of this study is to evaluate and compare the potential refractive outcomes using the Argos 1.5 biometer in the surgical planning for cataract extraction to that obtained from IOLMaster 700. Both devices are used as standard of care in surgical planning optimization for patients undergoing cataract surgery.
Interested in participating?
Request Info21 year and older
All sexes
Observational
Salt Lake City, Utah, 84107, United States
Location status: Recruiting
Allison Hales
CONTACT
Lexi Guild
CONTACT
Zachary J. Zavodni, MD
PRINCIPAL_INVESTIGATOR
Cataract surgery is one of the most performed surgical procedures globally. The goal of the cataract surgeon is to implant an intraocular lens (IOL) with an appropriate IOL power to compensate for the refractive error and leave the patient emmetropic. The accurate measurement of ocular parameters is therefore critical for the effective calculation of IOL power, which directly impacts postoperative visual outcomes. However, accurate IOL power determination is influenced by several factors, including the measurement techniques employed and the specific biometers used in the process.
Optical biometry has become the gold standard for ocular measurements since the introduction of the IOLMaster (Carl Zeiss Meditec AG, Jena, Germany) in 2001. The IOLMaster 700 utilizes SWEPT Source OCT (SS-OCT) with a wavelength of about 1055 nm to generate a 2D OCT cornea-to-retina cross-section scan of the eye. This allows for the computation of all axial biometry measurements, including axial lengths (AL), central corneal thickness (CCT), anterior chamber depths (ACD), and lens thickness (LT).
A relatively newer biometer, Argos 1.5 is also non-invasive and based on SS-OCT technology for IOL power determination with a similar wavelength of 1060 nm ±10nm. However, the IOLMaster 700 uses a traditional axial length computation approach that relies on a single refractive index whiles Argos 1.5 uses a segmented axial length approach based on multiple refractive indices attributed to each ocular component often referred as True AL.
This study aims to evaluate and compare the potential refractive outcomes and biometric measurements of patients undergoing cataract surgery when using Argos 1.5 versus the IOLMaster 700 with the available formulas on each device. By analyzing these biometric measurements, we aim to uncover insights that could enhance our understanding of how different measurement techniques influence postoperative visual outcomes, ultimately contributing to improved patient care.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: 1 month
Predicted refraction is defined as the refractive power predicted by the IOL calculation formula. The predicted refraction for planned IOL power when using Argos 1.5 will be compared to IOL Master 700 for available formulae common to both devices (e.g. SRK/T, Barrett Universal II, Holladay I, Holladay II etc.) using forest plots. Data for Barrett TAL [Argos only] will be analysed using descriptive statistics
Time frame: 1 month
The differences in IOL predicted power will be compared using descriptive statistics and forest plots.
For the second endpoint, we will be comparing the biometry measurements (ACD, CCT, WTW, LT, AL, K readings) from both devices for the same subject eye. The agreement will be quantified using Bland-Altman analysis for each measure for the total subject population.
Contact information is provided by the study sponsor or research team.
Allison Hales
CONTACT
Lexi L Guild
CONTACT
The Eye institute of Utah
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07468409
Cataract, Eye Diseases
Makati City, National Capital Region, Philippines
View Trial DetailsNCT07610226
Cataract, Eye Diseases
Greensboro, North Carolina, United States
View Trial DetailsNCT07715591
Anxiety Disorders, Behavior
Los Angeles, California, United States
View Trial DetailsNCT07471295
Cataract, Eye Diseases
Prague, Czechia
View Trial Details