NCT Number: NCT05814887
Peripheral intravenous catheters are necessary for in-hospital medical treatment. Malfunction due to occlusion or dislodgement is common, and increases the burden on health care.
The aim of this study is to determine if the use of a new medical device has an impact on mechanical complications rate when peripheral intravenous (IV) catheter is used. The study will also investigate the safety, opinions of healthcare personnel and health economic effects of this new device,
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Uppsala, Uppsala County, 75185, Sweden
It is estimated that around 1.5 billion peripheral intravenous catheters (PIVC) are sold every year globally, and placing them is one of the most common invasive procedures in hospitalised patients, with up to 90% receiving one, yet there is a failure rate of up to 69%. Some of the most common causes of failure are considered to be phlebitis, subcutaneous infiltration, occlusion and dislodgement. These failure rates vary widely, where published data suggests rates of 8-44% for phlebitis, 5-21% for infiltration, 7.6-16% for occlusion and 5-10% for dislodgement. Phlebitis, commonly defined as an inflammatory process in the wall of a vein, resulting in a blood clot formation; while infiltration is defined as the inadvertent leakage of a solution into the surrounding tissue; occlusion is defined as PIVC failure due to blockage where flushing and/or aspiration is not possible, and dislodgement the complete accidental/inadvertent removal of the PIVC before intended. Previous studies have suggested that mechanical irritation could be an important factor resulting in PIVC failure. In the case of phlebitis, mechanical movements against the endothelial wall could initiate a cascade of prothrombotic events resulting in the formation of a blood clot, something that has been demonstrated in a simulated environment.
Therefore, there is a need to investigate potential new methods for prevention of these mechanical complications, and one way could be in the reduction of mechanical forces acting on the vessels. The aim of this study is to investigate the safety and effectiveness of a new medical device in reducing the number of mechanical complications during IV therapy.
The investigators have divided the research questions into a primary endpoint and secondary endpoints.
The rate of mechanical complications of an IV therapy session using a new medical device (ReLink) compared to using current 'state of the art'.
The study is a randomized controlled trial to be run at Uppsala University Hospital. Patients will be randomly assigned to either the experimental group receiving IV infusion treatment using the new medical device ReLink, or the control group receiving IV infusion treatment without the device. Once the full intended IV infusion treatment has been completed, the same patient may be re-randomized and re-included in the trial. In case there is a mechanical complication resulting in the exchange of peripheral catheter, the patient will be re-randomized to either the control or intervention group. The risk of introducing a bias by re-randomizing the patients has been analysed and is considered to be minor. Firstly, in case of a re-randomization, this will take place after the follow-up of a peripheral catheter is completed. Secondly, re-randomization has been chosen instead of a cross-over design (where a patient's second peripheral catheter would automatically be selected to the other group) to avoid a spill-over effect from the patient themselves being biased against or in favour of using the device.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Medical device
Time frame: Up to one week from randomization
Mechanical complications is defined as phlebitis, subcutaneous infiltration, occlusion or dislodgement
Time frame: Up to one week from randomization
Recording of any adverse events during the trial
Time frame: Within one week of removal of the device
Questionnaire asking healthcare workers opinion, maximum score 5/ minimum score 0, high scores indicated better outcome
Time frame: Through study completion, an average of 1 year
Economical calculations based on additional materials and healthcare workers time
Uppsala University Hospital
Other
Acronym: ReLink
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05412108
Catheter Complications
Le Mans, France
View Trial DetailsNCT05741866
Cardiovascular Diseases, Catheter Complications
Herston, Queensland, Australia
View Trial DetailsNCT05380661
Anxiety Disorders, Anxiety State
Vancouver, British Columbia, Canada
View Trial DetailsNCT06014099
Catheter Complications
Hangzhou, Zhejiang, China
View Trial Details