Skip to main content
OpenTrials
Completed

NCT Number: NCT01426217

Reduction in IV Associated Contamination

The purpose of this study is to investigate whether implementing a novel syringe and IV stopcock cap system impregnated with alcohol will reduce IV catheter bacterial contamination and infections in patients.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Dartmouth-Hitchcock Medical Center

Lebanon, New Hampshire, 03756, United States

About this study

Bacterial contamination of patient intravenous stopcock sets is a common intraoperative event associated with increased patient mortality, possibly via an infectious mechanism. The most common type of intravenous tubing used in operating rooms is the open lumen stopcock set which lacks a barrier between the environment and intraluminal space, and thus the intravascular space of the patient. The stopcock connector can be easily contaminated by provider hands due to improper handling of the device and/or contaminated by soiled syringe tips subsequently connected to the device. Further, the stopcock connector is often left uncapped by the provider and directly exposed to the environment. Thus, common breaches in intraoperative aseptic practice of healthcare providers can lead to bacterial contamination of the endoluminal space of the open lumen device. The primary aim of the current study is to assess the efficacy of a passive bundle designed to decrease intravenous stopcock and tubing intraluminal bacterial contamination. This passive bundle includes two novel interventions, a DOCit station and HubScrub caps. The HubScrub is designed to clean the needleless connectors and open lumen stopcock systems. The DOCit station is designed to simultaneously clean the interior and exterior of needle-less luer connectors of syringes with isopropyl alcohol while also providing a method of storage and organization of multiple syringes. The investigators hypothesize that the application of this passive bundle to the standard open lumen system commonly employed by anesthesia providers in the operating room will significantly reduce bacterial contamination of standard 3-way open lumen stopcock sets and improve patient safety.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Adult patient undergoing surgery or procedure in operating room
  • Undergoing general anesthesia

Exclusion criteria

  • Children (age < 18 years)
  • Lack of intravenous access
  • failure of anesthesia provider to complete training on experimental device

Treatment and study plan

Passive Bundle PSI (Problem Solving Innovations) Medical HubScrub, PSI Medical DocIt

Device

Implementation of passive bundle which includes HubScrub and DocIt device into the operating room environment.

Other names: PSI Medical HubScrub, PSI Medical DocIt

Primary outcomes

  1. Presence of Bacterial IV Stopcock Lumen Contamination

    Time frame: 48 hours

    The presence of bacteria in the stopcock lumen was assessed by analyzing swab cultures of the lumens. Each swab potentially containing bacteria from any of the 3 lumens of the stopcock sets were analyzed

Secondary outcomes

  1. Presence of Positive Bacterial Culture in IV Stopcock Due to Effluent Contamination

    Time frame: Until positive, up to 5 days

    Open lumen ports were removed from the patient; sent directly to the anesthesiology microbiology laboratory; connected by the same clinical laboratory scientist to sterile catheters using sterile, aseptic technique; and injected directly into a BacT/Alert 3D system (bioMérieux Inc., Durham, NC) with 2 mL of sterile saline per port. BacT/Alert is a blood culture system that automatically monitors bacterial growth using colorimetry; a sensor inserted at the bottom of the bottle changes color on detecting the carbon dioxide produced by the growth of the bacteria. Catheters were then removed, and the bottles were directly incubated in the BacT/Alert system for 5 days or until positive. Once positive, the liquid in the bottle was examined to identify the organism.

Sponsors and collaborators

Lead sponsor

Dartmouth-Hitchcock Medical Center

Other

Collaborators

  • PSI Medical

Registry information

Official study title

Reduction in Intraoperative Lumen Contamination of Standard 3-Way Open Lumen Stopcock Sets Through Use of a Novel, Passive Bundle

Important dates

Study start
2011
Primary completion
2011
Study completion
2011
First posted
Aug 31, 2011
Registry last updated
Oct 18, 2018

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.