Skip to main content
OpenTrials
Recruiting

NCT Number: NCT06806709

Reducing Blood Culture Contamination With the Use of a Needle-less Blood Draw Device (The PIVO Trial)

Blood cultures (BCs) are a blood test to look for an infection. Two problems with the sample collection are contamination by germs outside of the blood and not collecting enough blood in the tube, resulting in unusable samples. Many patients requiring a BC also have a peripheral intravenous catheter ("catheter") but these are not normally used for blood sampling. This means that patients receive many painful needles for both catheter insertion and blood sampling. There is a needle-free blood collection device (PIVO Pro) which can be used with a catheter to collect a blood sample.

The goal of the PIVO Trial is to see if using the PIVO Pro for blood culture sample collection will have a lower amount of contamination than the usual method of blood sample collection. Patients 18 and older at 3 emergency departments will be included. Research nurses will look for patients in emergency who need a blood culture sample taken and they will be asked if they want to be involved in the trial. Half of the participants will use the PIVO Pro to take their blood sample and half will have the usual way of collecting blood.

Participants do not have to do anything specifically for the trial. Information about the blood collection and results of the blood culture will be collected from the medical records and recorded for the trial.

Recruiting

Interested in participating?

Request Info

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Caboolture Hospital, Caboolture, Queensland, Australia

Loading trial locations.

About this study

The PIVO™ Pro Needle-free Blood Collection Device (Becton, Dickinson and Company; Franklin Lakes) has been available for around a decade and involves advancing a flexible internal flow tube through the patient's Peripheral Intravenous Catheter (PIVC) to access a fresh blood sample beyond the PIVC tip. There is supporting evidence that PIVO is comparable to venepuncture for yielding non-Blood Culture (BC) samples without haemolysis and clotting and with equivalent laboratory values; does not negatively impact PIVC dwell time or replacement rates; decreases preanalytical errors and PIVC replacement; improves the rate and degree of haemolysis in comparison to venepuncture and central line collection; and reduces the prevalence of hospital-onset bacteraemia. However, there are limitations to previous research. Theoretically, for newly inserted PIVCs, the PIVO Pro will bypass a PIVC contaminated on insertion through the skin, to collect a clean blood sample from beyond the tip while also avoiding complications associated with PIVC blood draw. While the PIVO Pro is used in some hospitals as part of standard care, there is a need to confirm results relating to BCs in a randomized controlled trial (RCT).

The aim of this trial is to examine whether use of the PIVO Pro at initial PIVC start, compared to standard practice, decreases BC draw contamination rates.

Based on the aim, the primary objective is to compare the efficacy of the PIVO Pro with initial PIVC start for reducing contaminated BC episodes, to standard practice for BC set draw. 1148 adult participants will be randomised into the trial.

The secondary objectives are to:

  • Compare the effect of the PIVO Pro with initial PIVC start on fill volume of BC bottles, to standard practice for BC set draw.
  • Compare the efficacy of the PIVO Pro with initial PIVC start for improving the overall quality of BC set samples (composite of non-contamination and adequate fill volume), to standard practice for BC set draw.
  • Compare the efficacy of (i) the PIVO Pro (ii) venepuncture, and (iii) draw from initial PIVC start for BC set draw to achieve non-contamination and adequate fill volume
  • Compare the efficacy of the PIVO Pro with initial PIVC start for reducing antibiotic use, to standard practice for BC set draw.

At one hospital site, a sub-study will be conducted to compare PIVC failure outcomes following BC draw with the PIVO Pro with initial PIVC start, to BC set draw directly from a PIVC. The aim of the sub-study is to compare the rate of thrombus development and narrowing of vessel diameter (mm) in those participants that develop PIVC-associated complications versus those participants who do not.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Blood culture requested due to suspected bloodstream infection
  • Patients receiving a 22 gauge short peripheral intravenous catheter (or larger)

Exclusion criteria

  • Patients who have already commenced intravenous antimicrobial medications in the emergency department

Treatment and study plan

PIVO-Pro needle-free blood collection device

Device

The PIVO™ Pro Needle-free Blood Collection Device advances a flexible flow tube through the intravenous catheter to access optimal blood draw conditions, overcoming traditional hurdles to collect high-quality, reliable blood samples.

Primary outcomes

  1. Blood culture draw success without contamination.

    Time frame: Measured at baseline

    Blood culture draw contamination measured as laboratory identification of a common skin commensal in a single blood culture (BC) set in an episode. Should the same common skin commensal be identified by culture in ≥ 2 blood specimens collected on separate occasions (same or consecutive days; e.g., on the same day as the trial BC set/s draw but several hours later) AND the blood cultures are assigned separate specimen numbers, processed individually, and are reported separately in the final laboratory report, the result will be reclassified as being positive (i.e., not contaminated).

Secondary outcomes

  1. Blood culture draw underfill

    Time frame: Measured at baseline

    Inoculation of blood to optimal fill line on bottles or reported by pathology.

  2. Blood culture set quality

    Time frame: Measured at baseline

    Measured as a composite of blood culture non-contamination and adequate fill volume.

  3. Antibiotic use

    Time frame: Within 1 week of baseline.

    Measured as commencement of any antibiotic in response to blood culture results.

Study contacts

Contact information is provided by the study sponsor or research team.

Andrea Valks

CONTACT

[email protected]

+61 7 3346 6012

Claire Rickard

CONTACT

[email protected]

Sponsors and collaborators

Lead sponsor

The University of Queensland

Other

Collaborators

  • Becton, Dickinson and Company

Registry information

Official study title

Reducing Blood Culture Contamination With the Use of a Needle-less Blood Draw Device (PIVO Pro): An Adaptive Group Sequential Randomized Controlled Trial (The PIVO Trial)

Important dates

Study start
2025
Primary completion
2026
Study completion
2026
First posted
Feb 4, 2025
Registry last updated
Feb 4, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.