Department of Obstetrics and Gynecology, Division of Obstetrics and Feto-maternal Medicine, Medical University of Vienna
Vienna, 1090, Austria
NCT Number: NCT03981328
Real-time continuous glucose monitoring (CGM) systems provide users with information about current glucose levels and alert the patient before the upper or lower glucose threshold is reached or when glucose levels change rapidly. Hence, glycaemic excursions can be early identified and accordingly adapted by behavioural change or pharmacologic intervention. Randomized controlled studies adequately powered to evaluate the impact of long-term application of real-time CGM systems on the risk reduction of adverse obstetric outcomes are missing.
Looking for future studies?
Notify Me18 year–55 year
Female
Interventional
Not applicable
Vienna, 1090, Austria
Intervention: Device description The Dexcom G6 intended use is for the management of diabetes in persons aged 2 years and older. The Dexcom G6 System is intended to replace fingerstick blood glucose testing for diabetes treatment decisions. Interpretation of the Dexcom G6 System results should be based on the glucose trends and several sequential readings over time. The Dexcom G6 System also aids in the detection of episodes of hyperglycemia and hypoglycemia, facilitating both acute and long-term therapy adjustments. The Dexcom G6 System can be used alone or in conjunction with these digitally connected medical devices for the purpose of managing diabetes. The system consists of a sensor, transmitter, receiver, and mobile app. The sensor is a small, flexible wire inserted into subcutaneous tissue where it converts glucose into electrical current. The sensor incorporates an interferent layer that minimizes the effect of potential electroactive interferents, such as acetaminophen, by preventing it from reaching the sensor wire surface. The benefit of this interferent layer in blocking the effects of acetaminophen prevents falsely high glucose readings. Thus, users may ingest acetaminophen while wearing the G6 CGM system. The transmitter, which is connected to the sensor and worn on the body, samples the electrical current produced by the sensor and converts the measurement into a glucose reading using an onboard algorithm. The receiver and/or the app displays the glucose reading along with a rate of change arrow and a trend graph. Additionally, the receiver and/or app issues alarms and alerts to notify the patient of glucose level changes and other important system conditions. The app provides the additional capability to share data with "followers" using the Dexcom Share service. The receiver can be put into a blinded mode using CLARITY® software. In this mode, users are unable to see the CGM data or receive CGM alerts.
CGM Ancillary Devices Dexcom CLARITY® is an accessory to users of the Dexcom CGM system. It is a software program that allows the transfer of glucose data from the CGM system to Dexcom remote servers for data management to allow use of the CGM data by the user and study clinicians. Target ranges of 60 to 140 mg/dl [3.3 to 7.8 mmol/l] will be set and the patients will be introduced in the use of alarm settings. Both participants and study sites will use CLARITY® to transfer glucose data between user and study site, whether CGM is used in blinded or real-time mode. A CLARITY® mobile app can be used for retrospective review of glucose data on the smart device and can also be set up to allow receipt of push notifications of CGM data facilitating weekly data review. For all patients (intervention and control group) an anonymized CLARITY® account will be created by using a sequential study number which is allocated at randomization (sex will be female and birth date for each account will be set to 1.1.1990 for all accounts).
the study participants are able to invite followers to review their glucose levels).
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Users insert a tiny sensor wire just under their skin using an automatic applicator. The sensor can measure glucose readings in interstitial fluid throughout the day and night.
Each participant in the control group will be assigned a study blood glucose meter to measure and store their blood glucose values during the study. Therefore, the Contour® Next One system (or a comparable device) will be used. The meter has CE Mark clearance and is commercially available in Europe. Participants will receive an ample supply of meter test materials based on quantities routinely used.
Time frame: postpartum - up to 48 hours after delivery
To assess differences in the proportion of LGA newborns (birth weight >90. pct) in women with GDM using real-time CGM as compared to women with GDM using SMBG via capillary blood glucose monitoring.
Time frame: postpartum - up to 48 hours after delivery
newborn measurement
Time frame: postpartum - up to 48 hours after delivery
statistics
Time frame: postpartum - up to 48 hours after delivery
frequency of occurrences
Time frame: postpartum - up to 48 hours after delivery
newborn measurement
Time frame: postpartum - up to 48 hours after delivery
differences in neonatal hyperinsulinemia
Time frame: through study completion, an average of 9 months
maternal measurements
Time frame: through study completion, an average of 9 months
maternal
Time frame: through study completion, an average of 9 months
development until birth
Time frame: through study completion, an average of 9 months
maternal measurements
Time frame: through study completion, an average of 9 months
maternal measurements
Time frame: through study completion, an average of 1 year
development until birth
Time frame: through study completion, an average of 9 months
development until birth
Medical University of Vienna
Other
The Effectiveness of Real Time Continuous Glucose Monitoring to Improve Glycemic Control and Pregnancy Outcome in Patients With Gestational Diabetes Mellitus
Acronym: GRACE
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06226948
Arterial Occlusive Diseases, Arteriosclerosis
Maribor, Slovenia
View Trial DetailsNCT03443713
Autoimmune Diseases, Behavior
Portland, Oregon, United States
View Trial DetailsNCT00467675
CGM, Glucose Variability
Minneapolis, Minnesota, United States
View Trial DetailsNCT00465881
CGM, Diabetes
Minneapolis, Minnesota, United States
View Trial Details