Hospital for Tropical Diseases at Ho Chi Minh city
Ho Chi Minh City, 700000, Vietnam
NCT Number: NCT06034093
This study aims to investigate the feasibility of using a real-time artificial intelligent (AI)-assisted tool for Rectus Femoris cross sectional area measurement from muscle ultrasound to improve reliability, reduce inter- and intra-observer variability and reduce operator time spent on ultrasound examination
Looking for future studies?
Notify Me16 year and older
All sexes
Interventional
Not applicable
Ho Chi Minh City, 700000, Vietnam
This project proposes to develop computational methods to automatically analyze conventional 2D muscle ultrasound images in real time to assist operators circumvent achieve high quality reproducible views and measurements specifically for Rectus Femoris muscle.
Study design: This is a prospective observational study to test the reliability of AI-assisted muscle ultrasound at the patient's bedside compared to standard RFCSA ultrasound. All measurements will be performed in adult patients with severe tetanus (Ablett Grade 3 or 4) admitted to the Adult ICU at HTD expected to stay at least 5 days. All patients are on mechanical ventilation, muscle relaxation and neuromuscular blockers following the Ministry of Health guidelines.
Study procedures: Three ultrasound examinations will be carried out according to a standard operating procedure where patients are in the supine position with the leg in neutral rotation. Measurements will be taken using 12L-RS linear probe, Venue Go ultrasound machine (General Electric Healthcare, London, UK).
Statistical analysis: Study will compare the intra- and interobserver variability of measurements and examination duration. All statistical analysis was performed with R version 4.0.4.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
RAIMUS software provides automatic segmentation and size measurement for the RFCSA
Time frame: during the study procedure
In this trial, the users are randomly assigned to scan muscle ultrasound with and without AI-assisted software to measure the size of the Rectus Femoris muscle. The investigators will compare the reliability and agreement metrics of the RF measurement
Time frame: during the study procedure
In this trial, the users are randomly assigned to scan muscle ultrasound with and without AI-assisted software to measure the size of the Rectus Femoris muscle. The investigators will record the time needed to carry out the muscle ultrasound examinations
Oxford University Clinical Research Unit, Vietnam
Other
Real-time AI-assisted Muscle Ultrasound for Monitoring Muscle Mass Reduction in Intensive Care Unit Patients
Acronym: RAIMUS
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07724379
Bacterial Infections, Bacterial Infections and Mycoses
Beijing, Beijing Municipality, China
View Trial DetailsNCT06939777
Bacterial Infections, Bacterial Infections and Mycoses
Hefei, Anhui, China
View Trial DetailsNCT07444502
Actinomycetales Infections, Bacterial Infections
Bangkok, Thailand
View Trial DetailsNCT02118961
Actinomycetales Infections, Bacterial Infections
Fukuoka, Japan
View Trial Details