NCT Number: NCT00617084

Randomized, Two-arm, Non-inferiority Study Comparing Endeavor-Resolute Stent With Abbot Xience-V Stent

The RESOLUTE-III Allcomers trial is a prospective, multicenter, randomized, two-arm, international, non-inferiority, open-label study with 2300 patients at 15-20 centers. The study is a "real world, all comers" study.

Primary objective: to compare the Medtronic Endeavor-Resolute (Zotarolimus-Eluting stent) system with the Abbott XIENCE V (Everolimus-Eluting stent) system with respect to cardiac death, myocardial infarction (not clearly attributable to a non-target vessel), Target Lesion Revascularization at 1 year in a "real world" patient population.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Phase 4

Primary location

Stiftung Inselspital, Department of Cardiology

Bern, CH-3010, Switzerland

About this study

The RESOLUTE-III Allcomers trial is a prospective, multicenter, randomized, two-arm, international, non-inferiority, open-label study with 2300 patients at 15-20 centers. The study is a "real world, all comers" study.

Primary objective: to compare the Medtronic Endeavor-Resolute (Zotarolimus-Eluting stent) system with the Abbott XIENCE V (Everolimus-Eluting stent) system with respect to cardiac death, myocardial infarction (not clearly attributable to a non-target vessel), Target Lesion Revascularization at 1 year in a "real world" patient population.

Study hypothesis: To determine whether the Zotarolimus-Eluting stent (Medtronic Endeavor-Resolute) is non-inferior to the Everolimus-eluting stent (Abbott XIENCE V) in terms of the primary endpoint at 12 months after stent implantation.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Minimal age 18 years
  • Symptomatic coronary artery disease
  • Patient acceptable candidate for treatment with drug eluting stent in accordance with applicable guidelines
  • Presence of one or more coronary artery stenosis >50% with reference diameter 2.25-4.0mm which can be covered by one or multiple stents
  • Patient indication, lesion length and vessel diameter according to 'Instructions for Use' of study stents
  • Patient is willing and able to cooperate with study procedures and required follow up visits and patient or legal representative has been informed and agrees by signing EC approved written informed consent.

Exclusion criteria

  • Women of childbearing potential who do not have a negative pregnancy test within 7 days before procedure and women who are lactating
  • Known intolerance to aspirin, clopidogrel or ticlopidin, heparin, cobalt, nickel, chromium, molybdenum, polymer coatings, Zotarolimus, Everolimus, or contrast material
  • Participating in other trial before reaching primary endpoint
  • Planned surgery within 6 months of PCI unless dual antiplatelet therapy is maintained throughout the peri-surgical period.

Treatment and study plan

Medtronic Endeavor Resolute

Device

Medtronic Endeavor Resolute

Other names: Endeavor Resolute Zotarolimus-Eluting Coronary Stent System

Abbott Xience V

Device

Abbott Xience V

Other names: XIENCE V Everolimus Eluting Coronary Stent System

Primary outcomes

  1. Target Lesion Failure

    Time frame: 12 months

    Percentage of participants that had either Cardiac Death, Myocardial Infarction (not clearly attributable to a non-target vessel)or Target Lesion Revascularization (TLR, clinically indicated) after one year. MI: Q MI if new pathological Q waves and chest pain, non Q MI if CK elevated more than two times normal, troponin elevated more than normal, according to ARC definitions. TLR, clinically indicated if associated with ischemic symptoms and angiographic min lumen diameter bigger than fifty percent by QCA or without symptoms and min lumen diameter bigger than seventy percent. Measure average.

Secondary outcomes

  1. In-Stent Percent Diameter Stenosis

    Time frame: 13 Months

    In Stent Percent Diameter Stenosis at thirteen months. In Stent Percent Diameter Stenosis: measured percent of diameter stenosis at the region of the stent (calculated as 100x(RVD-MLD)/RVD using the mean values from 2 orthogonal views by QCA. RVD (Reference Vessel Diameter): average of normal segments within 10mm proximal and distal to target lesion from 2 orthogonal views using QCA. MLD (Minimal Lumen Diameter): average of 2 orthogonal views of the narrowest point wihtin the area of assessment. MLD measured during QCA by the angiographic core laboratory.

Sponsors and collaborators

Lead sponsor

Medtronic Vascular

Industry

Collaborators

  • Medtronic Cardiac Rhythm and Heart Failure

Registry information

Official study title

RESOLUTE-III All-comers Trial: A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention

Acronym: RESOLUTE-AC

Important dates

Study start
2008
Primary completion
2010
Study completion
2014
First posted
Feb 15, 2008
Registry last updated
Jun 6, 2014