UCSF Medical Center
San Francisco, California, 94143, United States
NCT Number: NCT00686231
The radial artery, which is located on the outer side of the forearm, can be used in interventional procedures, such as cardiac catheterization, to provide access to the arterial blood supply. In order to facilitate successful catheterization of the artery, a dilated artery and one free of arterial spasm is desirable. The proposed study will randomize twenty three healthy subjects in 2 visits to determine the effect of topical nitroglycerin on radial artery vasodilation. Radial artery diameter will be measured with ultrasound at regular intervals up to two hours.
Looking for future studies?
Notify Me18 year–35 year
All sexes
Interventional
Phase 1
San Francisco, California, 94143, United States
During the first study visit, as a dose-optimizing study, each subject will be randomly assigned to one of two Dose-Test arms to receive either 15mg or 30mg of nitroglycerin on one wrist and placebo on the other. Radial artery diameter will be measured with ultrasound at regular intervals up to two hours. On the second study visit, the same participants will be randomly assigned to one of two Combination-Test arms to receive bilateral topical application of either 20mg or 40mg of lidocaine; the lidocaine will be applied in combination with 30mg of nitroglycerin on one wrist and in combination with placebo on the other wrist. Measurements of radial artery diameter will be performed as in the first visit.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
15mg Nitroglycerin applied topically to one wrist
30mg Nitroglycerin applied topically to one wrist
20mg Lidocaine applied topically to one wrist in combination with nitroglycerin or placebo
40mg Lidocaine applied topically to one wrist in combination with nitroglycerin or placebo
Topical skin moisturizing cream with same appearance as active agent
Other names: skin moisturizing cream
Time frame: Baseline, 10 minutes, 30 minutes, 60 minutes, and 120 minutes after topical application at Visit 1
Radial artery diameter was measured with ultrasonography using a high-frequency (13 MHz) linear array transducer 2 cm proximal to the radial styloid process.
Time frame: Baseline, 10 minutes, 30 minutes, 60 minutes, and 120 minutes after topical application at Visit 2
Radial artery diameter was measured with ultrasonography using a high-frequency (13 MHz) linear array transducer 2 cm proximal to the radial styloid process. To compare combination of (Lidocaine + Nitroglycerin) or (Lidocaine + placebo), at visit 2, participants randomized to Comparison A received 30mg NTG + 20mg Lidocaine on one wrist, and placebo + 20mg Lidocaine on the other wrist; participants randomized to Comparison B received 30mg Nitroglycerin + 40mg Lidocaine on one wrist, and placebo + 40mg Lidocaine on the other wrist.
University of California, San Francisco
Other
The Effect of Topical Administration of Nitroglycerin and Lidocaine Versus Lidocaine Alone of the Radial Artery Diameter
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06068257
Breast Cancer, Breast Diseases
Orlando, Florida, United States
View Trial DetailsNCT06702423
Healthy
London, United Kingdom
View Trial DetailsNCT07223164
Healthy
Irvine, California, United States
View Trial DetailsNCT05595902
Healthy
Kadıköy, Istanbul, Turkey (Türkiye)
View Trial Details