Stanford University
Stanford, California, 94305, United States
NCT Number: NCT03170817
Accurate measurements from a non-invasive test like myocardial perfusion positron emission tomography/ computed tomography (PET/CT) may decrease the need for invasive procedures such as cardiac catheterization.The investigators wish to see if the measurements from cardiac catheterization can be predicted using a non-invasive 13N-NH3 digital PET/CT scan.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Stanford, California, 94305, United States
Cardiac imaging using standard-of-care Nuclear Medicine techniques assess the relative radiopharmaceutical distribution from coronary arteries to cardiac tissue. This standard interpretation however, lacks the clinical utility of modern quantitative techniques that are now routinely obtained during cardiac catheterization, such as fractional flow reserve (FFR). Cardiologists routinely base critical management decisions, including the choice for revascularization, stenting, or angioplasty, on these measurements.
Non-invasive measurements of MBF (Myocardial Blood Flow), CFR (Coronary Flow Reserve) and RFR (Relative Flow Reserve) using PET/CT have been investigated, but have yet to reach clinicl use. Given the inherent gains in sensitivity and resolution, digital PET/CT, may allow for a more robust and accurate platform to obtain quantitative measurements of MBF, CFR and RFR which may greatly enhance the clinical utility of cardiac PET/CT for management of coronary artery disease.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Patients with coronary artery disease undergo a N-13 ammonia rest/stress PET/CT scan.
These patients are given:
Total patient time will take approximately up to 120 minutes.
5-10 mCi intravenous injection of N-13 ammonia radiopharmaceutical at rest and at stress
0.4 mg/5mL intravenous injection to induce pharmacologic stress (Astellas Pharma US, Inc.)
Other names: Lexiscan
Time frame: an estimated average of 2 hours
Non-invasive measurements of myocardial blood flow (MBF) in milliliter/minute/gram using PET/CT scanner will be compared to invasive cardiac angiography values (current gold standard). MBF values are obtained using image-derived time activity curves from the left ventricular blood and myocardial tissue regions. These values represent radiotracer exchange between the blood and the tissue over time. The rate of radiotracer uptake into the myocardial tissue provides an estimate of MBF. Processing software will then use the time-activity curves to calculate MBF at rest and at stress.
Time frame: an estimated average of 2 hours
Non-invasive measurements of coronary flow reserve (CFR) using digital PET/CT scanner will be compared to the gold standard evaluation from invasive cardiac angiography. Discrepancy between PET measurements and cardiac angiography results will be reported. CFR is the ratio of MBF at peak blood flow to resting MBF.
Time frame: an estimated average of 2 hours
Non-invasive measurements of relative flow reserve (RFR) using digital PET/CT scanner will be compared to the gold standard evaluation from invasive cardiac angiography. Discrepancy between PET measurements and cardiac angiography results will be reported. RFR is the ratio of MBF during stress in an affected region of the left ventricle (LV) to MBF during stress in a normal region of the LV.
Time frame: an estimated average of 2 hours
Nuclear medicine physician diagnostic confidence will be assessed using a 5-point Likert scale. NM Physicians will compare images obtained from the 13N-NH3 PET/CT to images obtained from single photon emission computed tomography/CT (SPECT/CT).
Time frame: an estimated average of 2 hours
Overall study time as counted from initial administration of radiopharmaceutical to completion of image acquisition will be measured and compared to SPECT/CT overall exam time.
Time frame: an estimated average of 2 hours
Total radiation dose (measured in mSv) from 13N-NH3 PET/CT will be measured and compared to the dose typically given to patients during standard myocardial perfusion imaging SPECT/CT studies.
Stanford University
Other
Quantitative Rest/Stress Cardiac Perfusion Digital PET/CT: Comparison Between Noninvasive Imaging and Invasive Coronary Angiography.
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03188705
Arterial Occlusive Diseases, Arteriosclerosis
Lancaster, Pennsylvania, United States
View Trial DetailsNCT07468955
Arterial Occlusive Diseases, Arteriosclerosis
Kütahya, Center, Turkey (Türkiye)
View Trial DetailsNCT06029517
Arterial Occlusive Diseases, Arteriosclerosis
Buffalo, New York, United States
View Trial DetailsNCT04058990
Arterial Occlusive Diseases, Arteriosclerosis
Kitakyushu, Fukuoka, Japan
View Trial Details