Quantification of Distribution of the Mass Center for a Controlled Force Platform Reaction to the Ground

This study developed a controlled soil reaction force platform that provided controlled mechanical stimuli to quantify the distribution of the center of mass as a function of the angular variation of the ankle in the elderly in the upright position.

Completed

Looking for future studies?

Notify Me

Key information

Conditions

Age range

20 year–85 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

About this study

Usually the balance evaluation the center of mass displacement for the analysis of postural control is assessed by means of force platforms. However, most of these devices are stationary, that is the patient is the dynamic element which can generate an evaluation with high subjectivity index. Therefore, this study aimed at developed a reaction force to the ground platform which provides mechanical stimuli controlled to quantify the distribution of the mass center as a function of the angular variation in the elderly ankle in the upright position. The construction of the prototype was divided into 3 steps, based on the two-dimensional movement of the ankle joint. In the 1st stage the construction of the mechanical assembly; in the 2nd stage development of the electronics; and 3rd stage the development of the supervisory system (control system). The force plataform was evaluated following the engineering functional tests such as: characterization and calibration of the sensors, the definition of the transfer function and accuracy of tests of angular movements (+ 10 ° and -10 ° to the movements of inversion and eversion, + 15 and -15º to the movements of dorsiflexion and plantar flexion). For the tests with volunteers were selected 30 volunteers.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • We included in this study individuals male and female
  • Age ranging from 20 to 85 years
  • Asymptomatic individuals
  • Must walk without the use of an attachment
  • Do not present motor deficit that makes the study impossible

Exclusion criteria

  • Decompensated congestive heart failure
  • Neurological or neurological diseases that interfere with significant neuromotor
  • Individuals who did not agree to participate in the study

Treatment and study plan

Force plate

Device

Device: force plate An equipment model with the approach of providing the evaluated person with the movement that is closest to the biomechanical and functional reality of the ankle and foot joint and which could equalize the possible changes of the center of mass would contribute to the clinical evaluation and would provide a more efficient therapeutic reasoning rehabilitation.

Primary outcomes

  1. Mass distribution

    Time frame: 15 minutes

    The center of mass was measured by the patient remaining on the force platform, remaining for 10 seconds in each angulation variant Unit of measurement: Kilograms (kg)

Sponsors and collaborators

Lead sponsor

Universidade Cruzeiro do Sul

Other

Registry information

Important dates

Study start
2016
Primary completion
2016
Study completion
2016
First posted
May 16, 2018
Registry last updated
May 18, 2018

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.