Change in Cardiac Output
Time frame: From the beginning of the PCI until its conclusion. This period can be variable and is estimated in 40 to 270 minutes.
Numerical continuous variable representing the change in Cardiac Output (CO), following ventricular unloading. The PULSE trial will measure in real-time how discrepant this measurement can be when resulting from continuous or pulsatile flow ventricular assist devices. This is not a time-to-event outcome: the change in CO will be obtained from real-time data collected during the intervention. The time frame will be the time of the Intervention. Unit: L/min
-
Change on the Mean Pulmonary Capillary Wedge Pressure
Time frame: From the beginning of the PCI until its conclusion. This period can be variable and is estimated in 40 to 270 minutes.
Numerical continuous variable representing the change in Mean Pulmonary Capillary Wedge Pressure (mPCWP), following ventricular unloading. The PULSE trial will measure in real-time how discrepant this measurement can be when resulting from continuous or pulsatile flow ventricular assist devices. This is not a time-to-event outcome: the change in mPCWP will be obtained from real-time data collected during the intervention. The time frame will be the time of the Intervention. Unit: mmHg.
-
Change in the PCWP v-wave
Time frame: From the beginning of the PCI until its conclusion. This period can be variable and is estimated in 40 to 270 minutes.
Numerical continuous variable representing the change in PCWP v-wave (vPCWP), following ventricular unloading. The PULSE trial will measure in real-time how discrepant this measurement can be when resulting from continuous or pulsatile flow ventricular assist devices. This is not a time-to-event outcome: the change in vPCWP will be obtained from real-time data collected during the intervention. The time frame will be the time of the Intervention. Unit: mmHg.
-
Change in Mean Pulmonary Artery Pressure
Time frame: From the beginning of the PCI until its conclusion. This period can be variable and is estimated in 40 to 270 minutes.
Numerical continuous variable representing the change in Mean Pulmonary Artery Pressure (mPAP), following ventricular unloading. The PULSE trial will measure in real-time how discrepant this measurement can be when resulting from continuous or pulsatile flow ventricular assist devices. This is not a time-to-event outcome: the change in mPAP will be obtained from real-time data collected during the intervention. The time frame will be the time of the Intervention. Unit: mmHg.
-
Change in Pulmonary Artery Oxygen Saturation
Time frame: From the beginning of the PCI until its conclusion. This period can be variable and is estimated in 40 to 270 minutes.
Numerical continuous variable representing the change in Pulmonary Artery Oxygen Saturation, also known as Mixed Oxygen Saturation (SVO2), following ventricular unloading. The PULSE trial will measure in real-time how discrepant this measurement can be when resulting from continuous or pulsatile flow ventricular assist devices. This is not a time-to-event outcome: the change in SVO2 will be obtained from real-time data collected during the intervention. The time frame will be the time of the Intervention. Unit: %
-
Change in Right Atrial Pressure
Time frame: From the beginning of the PCI until its conclusion. This period can be variable and is estimated in 40 to 270 minutes.
Numerical continuous variable representing the change in Right Atrial Pressure (RAP), following ventricular unloading. The PULSE trial will measure in real-time how discrepant this measurement can be when resulting from continuous or pulsatile flow ventricular assist devices. This is not a time-to-event outcome: the change in RAP will be obtained from real-time data collected during the intervention. The time frame will be the time of the Intervention. Unit: mmHg.
-
Change in Preload-recruitable Stroke Work
Time frame: From the beginning of the PCI until its conclusion. This period can be variable and is estimated in 40 to 270 minutes.
Numerical continuous variable representing the change in Preload-recruitable Stroke Work (PRSW), following ventricular unloading. The PULSE trial will measure in real-time how discrepant this measurement can be when resulting from continuous or pulsatile flow ventricular assist devices. This is not a time-to-event outcome: the change in PRSW will be obtained from real-time data collected during the intervention. The time frame will be the time of the Intervention. Unit: mmHg
-
Change in the Starling Contractile Index
Time frame: From the beginning of the PCI until its conclusion. This period can be variable and is estimated in 40 to 270 minutes.
Numerical continuous variable representing the change in the Starling Contractile Index (SCI), following ventricular unloading. The PULSE trial will measure in real-time how discrepant this measurement can be when resulting from continuous or pulsatile flow ventricular assist devices. This is not a time-to-event outcome: the change in SCI will be obtained from real-time data collected during the intervention. The time frame will be the time of the Intervention. Unit: mmHg/ml⋅s
-
Change in End-systolic Wall Stress
Time frame: From the beginning of the PCI until its conclusion. This period can be variable and is estimated in 40 to 270 minutes.
Numerical continuous variable representing the change in the End-systolic Wall Stress (WSes), following ventricular unloading. The PULSE trial will measure in real-time how discrepant this measurement can be when resulting from continuous or pulsatile flow ventricular assist devices. This is not a time-to-event outcome: the change in WSes will be obtained from real-time data collected during the intervention. The time frame will be the time of the Intervention. Unit: mmHg.
-
Change in the first derivative of pressure over time
Time frame: From the beginning of the PCI until its conclusion. This period can be variable and is estimated in 40 to 270 minutes.
Numerical continuous variable representing the change in the first derivative of pressure over time (+dP/dtmax), following ventricular unloading. The PULSE trial will measure in real-time how discrepant this measurement can be when resulting from continuous or pulsatile flow ventricular assist devices. This is not a time-to-event outcome: the change in +dP/dtmax will be obtained from real-time data collected during the intervention. The time frame will be the time of the Intervention. Unit: mmHg/s
-
Change in Systemic Vascular Resistance
Time frame: From the beginning of the PCI until its conclusion. This period can be variable and is estimated in 40 to 270 minutes.
Numerical continuous variable representing the change in the Systemic Vascular Resistance (SVR), following ventricular unloading. The PULSE trial will measure in real-time how discrepant this measurement can be when resulting from continuous or pulsatile flow ventricular assist devices. This is not a time-to-event outcome: the change in SVR will be obtained from real-time data collected during the intervention. The time frame will be the time of the Intervention. Unit: (dyn∙s)/(cm^(-5))
-
Change in Pulmonary Vascular Resistance
Time frame: From the beginning of the PCI until its conclusion. This period can be variable and is estimated in 40 to 270 minutes.
Numerical continuous variable representing the change in the Pulmonary Vascular Resistance (PVR), following ventricular unloading. The PULSE trial will measure in real-time how discrepant this measurement can be when resulting from continuous or pulsatile flow ventricular assist devices. This is not a time-to-event outcome: the change in PVR will be obtained from real-time data collected during the intervention. The time frame will be the time of the Intervention. Unit: (dyn∙s)/(cm^(-5))
-
Change in Cardiac Power Output
Time frame: From the beginning of the PCI until its conclusion. This period can be variable and is estimated in 40 to 270 minutes.
Numerical continuous variable representing the change in the Cardiac Power Output (CPO), following ventricular unloading. The PULSE trial will measure in real-time how discrepant this measurement can be when resulting from continuous or pulsatile flow ventricular assist devices. This is not a time-to-event outcome: the change in CPO will be obtained from real-time data collected during the intervention. The time frame will be the time of the Intervention. Unit: Watts
-
Change in Hematocrit
Time frame: From baseline (beginning of PCI) to immediately after the procedure and 12 hours after PCI.
Numerical continuous variable. Change in Hematocrit (Ht) as an indicative of bleeding or hemolysis. Unit: %
-
Change in Hemoglobin
Time frame: From baseline (beginning of PCI) to immediately after the procedure and 12 hours after PCI.
Numerical continuous variable. Change in Hemoglobin (Hb) as an indicative of bleeding or hemolysis. Unit: mmol/L
-
Change in Platelet Count
Time frame: From baseline (beginning of PCI) to immediately after the procedure and 12 hours after PCI.
Numerical continuous variable. Change in Platelet Count as an indicative of bleeding events. Unit: 10^9/L
-
Change in haptoglobin
Time frame: From baseline (beginning of PCI) to immediately after the procedure and 12 hours after PCI.
Numerical continuous variable. Change in haptoglobin as an indicative of hemolytic events. Unit: g/L
-
Change in total and conjugated bilirubin
Time frame: From baseline (beginning of PCI) to immediately after the procedure and 12 hours after PCI.
Numerical continuous variable. Change in total and conjugated bilirubin as an indicative of hemolytic events. Unit: umol/L
-
Change in lactate dehydrogenase
Time frame: From baseline (beginning of PCI) to immediately after the procedure and 12 hours after PCI.
Numerical continuous variable. Change in lactate dehydrogenase as an indicative of hemolytic events. Unit: U/L.
-
Change in hs-troponin
Time frame: From baseline (beginning of PCI) to immediately after the procedure and 12 hours after PCI.
Numerical continuous variable. Change in hs-troponin as an indicative of myocardial necrosis. Unit: ng/L
-
Change in creatinephosphokinase
Time frame: From baseline (beginning of PCI) to immediately after the procedure and 12 hours after PCI.
Numerical continuous variable. Change in creatinephosphokinase (CK) as an indicative of myocardial necrosis. Unit: U/L
-
Change in creatinophosphokinase MB mass assay
Time frame: From baseline (beginning of PCI) to immediately after the procedure and 12 hours after PCI.
Numerical continuous variable. Change in creatinophosphokinase MB mass assay (CKMB-mass) as an indicative of myocardial necrosis. Unit: ug/L
-
Change in N-terminal pro b-type natriuretic peptide
Time frame: From baseline (beginning of PCI) to immediately after the procedure and 12 hours after PCI.
Numerical continuous variable. Change in N-terminal pro b-type natriuretic peptide (NT-proBNP) as an indicative of chamber overload. Unit: pmol/L
-
Change in serum lactate
Time frame: From baseline (beginning of PCI) to immediately after the procedure and 12 hours after PCI.
Numerical continuous variable. Change in serum lactate as an indicative of hypoperfusion states. Unit: mmol/L.
-
Change in serum creatinine
Time frame: From baseline (beginning of PCI) to immediately after the procedure and 12 hours after PCI.
Numerical continuous variable. Change in serum creatinine as an indicative of acute kidney injury. Unit: umol/L
-
All-cause mortality
Time frame: 30 days follow up
Constitutes one of the components of the MACCE composite endpoint: all-cause mortality, acute myocardial infarction, stroke or transient ischemic attack (TIA), and repeat revascularization (PCI or CABG). Time-to-event variable, measured in days.
-
Acute myocardial infarction
Time frame: 30 days follow up
According to the "Fourth Universal Definition of Acute Myocardial Infarction". Constitutes one of the components of the MACCE composite endpoint: all-cause mortality, acute myocardial infarction, stroke or transient ischemic attack (TIA), and repeat revascularization (PCI or CABG). Time-to-event variable, measured in days.
-
Stroke or transient ischemic attack
Time frame: 30 days follow up
As per VARC 2 definitions 2013 J Thorac Cardiovasc Surg 2013;145:6-23. Constitutes one of the components of the MACCE composite endpoint: all-cause mortality, acute myocardial infarction, stroke or transient ischemic attack (TIA), and repeat revascularization (PCI or CABG). Time-to-event variable, measured in days.
-
Repeat revascularization
Time frame: 30 days follow up
As per ARC definition - Circulation. 2007;115:2344-2351. Constitutes one of the components of the MACCE composite endpoint: all-cause mortality, acute myocardial infarction, stroke or transient ischemic attack (TIA), and repeat revascularization (PCI or CABG). Time-to-event variable, measured in days.
-
Major Bleeding
Time frame: 30 days follow up
Major bleeding (BARC 3 to 5), according to the BARC Bleeding Classification (BARC definitions 2011. Circulation. 2011; 123(23): 2736-47. Time-to-event variable, measured in days.
-
Major vascular complications
Time frame: 30 days follow up
Major vascular complications (e.g.: arteriovenous fistula, limb ischemia), as per VARC-2 definitions (VARC 2 definitions 2013, J Thorac Cardiovasc Surg 2013;145:6-23) . Time-to-event variable, measured in days.
-
Acute renal dysfunction
Time frame: 30 days follow up
Acute renal dysfunction (AKIN 1 or above), using the AKIN Classification as described in the VARC-2 definitions (VARC 2 definitions 2013 J Thorac Cardiovasc Surg 2013;145:6-23).
-
Increase in Aortic regurgitation
Time frame: 30 days follow up
Increase in aortic regurgitation by more than one grade (TTE). Binary outcome obtained at the second echocardiogram, performed at discharge.
-
Severe hypotension
Time frame: First 48 hours after the start of PCI.
Severe hypotension (MAP < 60mmHg for more than 10 minutes despite fluid resuscitation or use of vasoactive amines to maintain MAP ≥ 60 mm Hg), or shock, defined based on the definition from the SHOCK trial (1) SBP ≤ 90mmHg for at least 30 minutes, (2) Need for vasopressors to maintain SBP > 90mmHg; (3) evidence of end-organ hypoperfusion; (4) Evidence of elevated filling pressures. A similar concept has been applied in the BCIS-1 study to measure procedural instability (JAMA. 2010;304(8):867-874).
-
Ventricular arrhythmias
Time frame: 30 days follow up
VT requiring cardioversion and / or need for CPR. Binary outcome, VF at anytime during follow up. Time-to-event analysis, measured in days.
-
Angiographic failure
Time frame: Assessed at the end of the PCI. This time point (end of PCI) can be variable and is estimated in 40 to 270 minutes after the beginning of the procedure.
Angiographic failure/ procedural failure, as defined in the 2011 ACCF/AHA/SCAI Guideline for Percutaneous Coronary Intervention Circulation. 2011;124:e574-e651): post PCI TIMI flow < III, residual stenosis (>50% post-balloon or > 10% post stenting), or presence of thrombus, side branch loss or flow limiting dissection. It is a binary outcome (yes/no answer). No time-to-event analysis will be applied.
-
Time of hospitalization
Time frame: 30 days follow up
Time to hospital discharge (in days).
-
Change in Left ventricular ejection fraction
Time frame: From baseline (beginning of PCI) to the moment of discharge, assessed up to 30 days.
Numerical continuous variable. Change in LVEF measured by trans-thoracic echocardiography at baseline and discharge. Not a time-to-event variable. Unit: %