Pulse Transit Time in Anesthetized Patients: Blood Pressure or Cardiac Output as Measured With NICOM Monitor

Pulse transit time (PuTT) - the time between R wave on ECG and initiation of upstroke in the peripheral arterial waveform - described in the previous studies as value that reflects changes in both blood pressure and blood volume. The investigators are assuming that PuTT changes reflect the dynamic of systolic blood pressure but not cardiac output fluctuations.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Carmel Medical Center, Haifa, Israel

Loading trial locations.

About this study

Background Pulse transit time (PuTT) - the time between R wave on ECG and initiation of upstroke in the peripheral arterial waveform - described in the previous studies as value that reflects changes in both blood pressure and blood volume. We are assuming that PuTT changes reflect the dynamic of systolic blood pressure but not cardiac output fluctuations.

Clinical trial objectives Investigate a link between PuTT (Pulse transit time) and changes in blood pressure and cardiac output measured by non-invasive cardiac output monitoring device (NICOM).

Endpoints PuTT Blood pressure: systolic, diastolic, mean Heart rate Cardiac output-Index Systemic vascular resistance-Index

Prospective nonrandomized clinical trial

Inclusion criteria

Need for continuous invasive monitoring of blood pressure - according to the type of surgery the patient's health status Normal sinus rhythm

Exclusion criteria

Pregnancy Cave to Nitroglycerine or Phenylephrine Chronic renal failure with creatinine level above 2 mg%

Safety assessment methods Monitoring of cardiac output is one of the most important elements of hemodynamic monitoring. In the past this monitoring was based mainly on the invasive and awkward methods causing usage only in exceptional cases. NICOM device allows accurate non-invasive monitoring of cardiac output During anesthesia patient care changes are made according to changes in vital indicators such as blood pressure, pulse, cardiac output. So during the study, anesthesia care can be affected by the indices obtained using a NICOM.

Data processing and analysis During the surgery the continuous monitoring of blood pressure by peripheral artery catheter and cardiac output by NICOM will be applied.

In case of hemodynamic changes the patient will be treated according to the standard care:

In case of decrease of systolic blood pressure below 80 mmHg (in the patients with history of arterial hypertension - below 90 mmHg) and HR is above 70 bpm the patient will be treated by repeated boluses of Phenylephrine 50-100 mcg until the systolic blood pressure will increase by at least 20%.

Intraoperative hypertension above 160 mmHg will be treated by repeated boluses of Nitroglycerine 100 mcg until the systolic blood pressure will decrease by at least 20%.

Hypovolemia will be treated by boluses of colloid solution - HAES 6% - at dose of 7 ml/kg of body mass during 15 min.

Study procedures

Cardiac output will be measured by NICOM just before and after each treatment of hemodynamic events that described above. Simultaneous records of ECG, arterial and plethysmographic waveforms will be made just before and after each event.

Systolic blood pressure and PuTT will be measured OFFLINE from the recorded waveforms.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • All patients scheduled for elective surgery and require invasive monitoring of blood pressure according to their medical condition and type of surgery

Exclusion criteria

  • Patients under the age of 18

Treatment and study plan

non-invasive cardiac output monitoring

Device

During the surgery the continuous monitoring of blood pressure by peripheral artery catheter and cardiac output by NICOM (non-invasive cardiac output monitoring) will be applied. In case of intraoperative hemodynamic changes (hypertension, hypotension) the patient will be treated according to the standard care by Phenylephrine, Nitroglycerine or Colloid fluid boluses. Cardiac output will be measured by NICOM just before and after each treatment of hemodynamic events that described above. Simultaneous records of ECG, arterial and plethysmographic waveforms will be made just before and after each event. Systolic blood pressure and PuTT will be measured OFFLINE from the recorded waveforms

Other names: Cheetah Reliant, NICOM, Cheetah Medical

Primary outcomes

  1. Pulse transit time (PuTT)

    Time frame: Two minutes after each intervention (giving Nitroglycerine, Phenylephrine or Fluid loading)

    Simultaneous record of arterial line waveform and ECG will be made just before and 2 minute after giving one of treatments (Phenylephrine, Nitroglycerine or fluid bolus). PuTT will be measured offline from the record

Sponsors and collaborators

Lead sponsor

Carmel Medical Center

Other

Registry information

Official study title

Pulse Transit Time in Anesthetized Ventilated Patients: Affect of Blood Pressure or Cardiac Output as Measured With NICOM Monitor

Acronym: PuTT-NICOM

Important dates

Study start
2011
Primary completion
2013
Study completion
2013
First posted
Dec 14, 2010
Registry last updated
Nov 26, 2013

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.