The aim of this project is to test the accuracy of pulse oximeters during mild, moderate and severe hypoxia. This is done by comparing the reading of the pulse oximeter during brief, steady state hypoxia with a gold-standard measurement of blood oxygen. This study will be done on healthy male or females between the age group of 18-50.
Interested in participating?
Request Info18 year–50 year
All sexes
Observational
San Francisco, California, 94143, United States
Location status: Recruiting
This study is to determine the accuracy of pulse oximeters, which measure blood oxygen by shining light through fingers, ears or other parts of the body, without requiring blood sampling.
The aim of this project is to test the accuracy of pulse oximeters during mild, moderate and severe hypoxia. This is done by comparing the reading of the pulse oximeter during brief, steady state hypoxia with a gold-standard measurement of blood oxyhemoglobin saturation (arterial blood sample processed in a laboratory hemoximeter).The data obtained is submitted by pulse oximeter manufacturers to the FDA for device approval.
Studies normally involve 10-14 normal adult volunteer paid subjects, with 20-25 1-2 ml arterial blood samples from each subject obtained at different steady-state levels of hypoxia from 70-100%. Blood samples obtained from an arterial line are measured in a hemoximeter to determine true saturation value. Some sponsors may not require any blood sampling. Some sponsors may require additional blood samples, up to 35 samples may be drawn. Readings from the test pulse oximeters are recorded and compared to these "gold-standard" blood values. The pulse oximeter probes may be located at a variety of sites on the subjects, including fingers, toes, ears, forehead, scalp and bridge of the nose. These detector-probes are all non-invasive.
The level of hypoxia is measured and controlled by the investigator. A computer program that displays a prediction, breath by breath, the arterial oxygen saturation, (SaO2) of the study subject. SaO2 is computed from end-expired Po2 and Pco2 as determined by mass spectrometer gas analysis. This information permits the inspired gas mixture of air, plus CO2 and nitrogen, to be adjusted by an operator watching the value computed after each expiration on an analog meter. This computer-estimated saturation is adjusted by the operator to one of 6 levels of predicted saturation, and is held stable for about 30 seconds at each level. Two or three "runs" are conducted per subject. Each "run" lasts 10-15 min and 4 to 5 plateaus are tested per run. The manufacturer may choose the target values. Plateaus are typically sought at 96%, 87%, 77%, 92%, 82% and 72%. Other manufacturers have asked for an equal number of data points but with all points between 70% and 100%. Some sponsors may also request additional variables to be measured during testing including high or low CO2, where subjects will be asked to hyperventilate; low perfusion, where subjects will be asked to lay flat, or with their head up or down; testing pulse oximeters during motion, or with the subject's hand fixed to a motion machine. The subject's will be informed by the study staff and in the consent form if any of these additional procedures apply.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Stable hypoxemia is created in healthy subjects by having them breathe hypoxic air mixtures
Time frame: 08/01/2025
Reading on pulse oximeter device which is an estimate of the patient's blood oxygen level.
Time frame: 08/01/2025
Arterial blood gas sample results showing exact SpO2 levels. SpO2 ranges from 1% to 100%. Our target SpO2 levels are between 67% and 100%.
Time frame: 08/01/2025
ITA stands for individual typology angle from a spectrophotometer which is an objective measurement of skin pigmentation. The categories for the ITA scale are the following: > 55 Very Light, 41 to 55 Light, 28 to 41 Intermediate, 10 to 28 Tan, -30 to 10 Brown, < -30 Dark.
Time frame: 08/01/2025
Finger diameter is measured to ensure that the pulse oximeters being tested work with a variety of finger sizes. Finger diameter is measured in mm.
Time frame: 08/01/2025
The Monk scale is a subjective categorization of skin pigmentation. The Monk Scale is a 10 shade scale designed to to be easy-to-use for development and evaluation of technology while presenting a more representative range of skin tones than other common qualitative scales. The Monk Scale is from A to J. A being the lightest skin color and J the darkest.
Contact information is provided by the study sponsor or research team.
Michael Lipnick, MD
CONTACT
Phil Bickler, MD, PhD
CONTACT
University of California, San Francisco
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06692400
Adult, Biomarkers / Blood
Loma Linda, California, United States
View Trial DetailsNCT07431580
Altitude Sickness, Dyspnea
Zurich, Canton of Zurich, Switzerland
View Trial DetailsNCT07608913
Altitude Sickness, Altitude Training Adaptation
Macao, China
View Trial DetailsNCT05048680
Aging, Behavior
La Tronche, Auvergne-Rhône-Alpes, France
View Trial Details