NCT Number: NCT02186561
Prospective Study on Embolization of Intracranial Aneurysms With Pipeline™ Embolization Device
The purpose of this study is to assess the safety and effectiveness of the Pipeline™ device in the treatment of unruptured, wide-neck intracranial aneurysms.
Looking for future studies?
Notify MeKey information
Conditions
Age range
22 year–80 year
Sex eligibility
All sexes
Study type
Interventional
Phase
Not applicable
Primary location
Toronto Western Hospital, Toronto, Ontario, Canada
Who can participate
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
- Subject has provided written informed consent using the IRB/EC-approved consent form and agrees to comply with protocol requirements.
- Age 22-80 years.
- Subject has a target intracranial aneurysm (IA) located in the:
- Internal carotid artery (up to the carotid terminus) OR
- Vertebral artery segment up to and including the posterior inferior cerebellar artery
- Subject has a target IA that is ≤ 12 mm.
- Subject has a target IA that has a parent vessel with diameter 1.5-5.0 mm distal/proximal to the target IA.
- Subject has a target IA with an aneurysm neck ≥ 4mm or a dome to neck ratio ≤ 1.5.
- Subject has a pre-procedure PRU value between 60-200.
Exclusion criteria
- Subject has received an intracranial implant (e.g. coils) in the area of the target IA within the past 12 weeks.
- Subarachnoid hemorrhage in the past 30 days.
- Subject with anatomy not appropriate for endovascular treatment due to severe intracranial vessel tortuosity or stenosis determined from baseline or pre-procedure imaging, or a history of intracranial vasospasm not responsive to medical therapy.
- Major surgery in the last 30 days.
- History of irreversible bleeding disorder and/or subject presents with signs of active bleeding.
- Any known contraindication to treatment with the Pipeline™ device, including:
- Stent is in place in the parent artery at the target IA location
- Contraindication to dual antiplatelet therapy
- Relative contraindication to angiography (e.g., serum creatinine >2.5 mg/dL, allergy to contrast that cannot be medically controlled).
- Known severe allergy to platinum or cobalt/chromium alloys.
- Evidence of active infection at the time of treatment (e.g., fever with temperature >38°C and/or WBC >1.5 109/L).
- The Investigator determines that the health of the subject or the validity of the study outcomes (e.g., high risk of neurologic events, worsening of clinical condition in the last 30 days) may be compromised by the subject's enrollment.
- Pregnant or breast-feeding women or women who wish to become pregnant during the length of study participation.
- Participating in another clinical trial during the follow-up period that could confound the treatment or outcomes of this investigation.
Treatment and study plan
Primary outcomes
-
The Percentage of Participants With the Occurrence of Major Stroke in the Territory Supplied by the Treated Artery or Neurological Death at 12-Months Post Procedure
Time frame: Up to 12 Months Post Procedure
The primary safety endpoint was defined as a stroke which results in focal neurological deficit for 24 hrs or more and increases the NIH Stroke Scale of the subject by ≥ 4 along with an imaging correlate. Missing data for subjects who failed to complete the 12- month post-procedure evaluation without any evidence of a major stroke in the territory supplied by the treated artery or neurological death were imputed in the analysis using multiple imputation. Multiple imputation provides a mechanism for deriving estimates for a population where not all of the patients have an endpoint determination.
-
The Percentage of Participants With Complete Aneurysm Occlusion (Defined as Raymond Roy Grade 1) Without Significant Parent Artery Stenosis (≤ 50%) or Retreatment of the Target Aneurysm at 12-Months Post-Procedure
Time frame: Up to 12 Months Post Procedure
The definitions for the three components of the primary effectiveness endpoint were: 1) retreatment, defined as all retreatment procedures occurring between the index procedure and 1 Year post-procedure; 2) complete aneurysm occlusion based on Core Laboratory review of 1-year images and 3) significant parent artery stenosis, based on Core Laboratory review of 1-year images. The Raymond-Roy Grading scale is used for judging intracranial aneurysm (IA) endosaccular embolization success. Grade I is completion occlusion with no flow of contrast seen in the aneurysm sac, Grade II is partial occlusion with some flow or eddy flow in the aneurysm sac and Grade III is residual aneurysm or Incomplete occlusion with apparent flow in the aneurysm sac.
Multiple imputation provides a mechanism for deriving estimates for a population where not all of the patients have an endpoint determination.
Secondary outcomes
-
The Number of Participants With a Major Stroke in the Territory Supplied by the Treated Artery or Neurological Death at 30-days Post Procedure Due to Procedural Complications
Time frame: Up to 30 days, Post Procedure
Major Stroke is defined as a stroke which results in focal neurological deficit for 24 hrs or more and increases the NIH Stroke Scale of the subject by ≥ 4 along with an imaging correlate. Neurological death is any subject death due to neurologic reasons.
-
The Number of Participants Who Experienced Delayed Intracerebral Hemorrhage > 30 Days Post-Procedure
Time frame: > 30 days, Post Procedure
For the purpose of this protocol, delayed intracerebral hemorrhage was defined as hemorrhage within the fixed vault of the cranium (skull) occurring greater than 30 days post-procedure.
-
The Number of Participants With Successfully Deployed Investigational Device
Time frame: Index Procedure
The secondary outcome measures provides the number of participants successfully implanted with the Investigational device during the study index procedure at the target site.
Sponsors and collaborators
Lead sponsor
Medtronic Neurovascular Clinical Affairs
Industry
Registry information
Official study title
Prospective Study on Embolization of Intracranial Aneurysms With the Pipeline™ Device (PREMIER)
Acronym: PREMIER
Important dates
- Study start
- 2014
- Primary completion
- 2016
- Study completion
- 2018
- First posted
- Jul 10, 2014
- Registry last updated
- Dec 27, 2019
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Related clinical trials
Published trials that share one or more normalized conditions with this study.
Compare the Safety and Effectiveness of Two Different Kinds of Stent System in Intracranial Aneurysms
NCT06303063
Aneurysm, Brain Diseases
Beijing, China
View Trial DetailsTrenza Embolization Device for Intrasaccular Aneurysm Treatment
NCT04380350
Aneurysm, Brain Diseases
Salzburg, Austria
View Trial DetailsPostmarket Study of Tarvos Microguidewire in Neurovascular Interventional Surgery
NCT07500155
AV Fistula, AVM - Cerebral Arteriovenous Malformation
Xingtai, China
View Trial DetailsSuccess in Comaneci-assist Coils Embolization Surveillance Study (SUCCESS)
NCT04518670
Aneurysm, Brain Diseases
Mobile, Alabama, United States
View Trial Details