Augenabteilung, Klinik Hietzing, Wiener Gesundheitsverbund
Vienna, State of Vienna, 1130, Austria
NCT Number: NCT07688681
This study compares two types of artificial lens (intraocular lens, or IOL) used during cataract surgery. Both are extended depth-of-focus (EDOF) lenses, designed to give clear vision across a range of distances - far and intermediate - so that people depend less on glasses after surgery. The two lenses, the Tecnis PureSee and the 1stQ Comfort Z-EDOF, use different optical designs, and it is not yet known whether one provides a wider range of clear vision than the other.
Adults having cataract surgery in both eyes may take part. Each participant is randomly assigned to receive one of the two lens types, and the same lens type is implanted in both eyes. Neither the participant nor the staff measuring vision knows which lens was used until the main 6-month assessment is complete.
After surgery, participants attend check-ups at 1, 3, and 6 months. The study measures how wide a range of distances each person can see clearly, along with vision at different distances, quality of vision, side effects such as glare or halos, and overall satisfaction. The results will help doctors and patients choose between these lens types.
Trial opening soon.
Get Notified40 year and older
All sexes
Interventional
Not applicable
Vienna, State of Vienna, 1130, Austria
Background and rationale: Extended depth-of-focus (EDOF) intraocular lenses (IOLs) extend the range of functional vision beyond that of conventional monofocal IOLs by modifying the eye's wavefront to create an elongated focal range, while aiming to limit the photic phenomena (halos, glare, starbursts) often associated with multifocal IOLs. Different EDOF platforms use fundamentally different optical strategies, yet direct comparative evidence between EDOF designs from prospective randomized trials is limited; most published studies compare an EDOF IOL with monofocal or multifocal lenses rather than with another EDOF design. This trial provides a head-to-head comparison of two purely refractive EDOF platforms that employ different optical principles: the Tecnis PureSee (Johnson & Johnson Vision), a refractive EDOF design with a continuous power profile and negative spherical aberration, and the 1stQ Comfort Z-EDOF (1stQ GmbH), a refractive aspheric EDOF design with a modified spherical aberration profile.
Design: This is a single-center, prospective, randomized, parallel-group comparative study conducted at the Department of Ophthalmology, Klinik Hietzing, Vienna, Austria. Patients undergoing bilateral cataract surgery are randomized 1:1 to receive one of the two EDOF IOL platforms, implanted bilaterally (the same platform in both eyes). Randomization uses permuted blocks and is stratified by toric versus non-toric IOL variant; patients with preoperative corneal astigmatism greater than 0.75 D receive the toric version of the assigned platform. Target refraction is emmetropia in the dominant eye and approximately -0.50 D in the non-dominant eye. Participants and outcome assessors are masked to lens allocation until the 6-month primary endpoint assessment is complete; the operating surgeon cannot be masked.
The study compares monocular (eye-level) and binocular (patient-level) outcomes between the two platforms. The primary endpoint is the monocular distance-corrected defocus range at the 0.2 logMAR threshold, measured 6 months after surgery from a standardized defocus curve (4-meter ETDRS chart, defocus +1.0 D to -3.5 D in 0.5 D steps). Secondary assessments include visual acuity at multiple distances, the complete defocus curve, manifest refraction and astigmatic vector components, higher-order wavefront aberrations, rotational stability of the toric variants, patient-reported visual function and quality of vision (including halos, glare, and starbursts), spectacle independence, satisfaction, and surgical safety.
Assessments are performed preoperatively and at 1, 3, and 6 months postoperatively. The primary analysis compares the mean monocular defocus range between groups using one eye per patient (the first-operated eye), with sensitivity analyses using both eyes and appropriate adjustment for within-patient correlation. The study is regulated as a post-market clinical follow-up (PMCF) investigation under Article 74(1) of Regulation (EU) 2017/745; both lenses are CE-marked and used within their approved intended purpose.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Phacoemulsification with bilateral implantation of the Tecnis PureSee refractive EDOF IOL in the capsular bag. Toric variant used for preoperative corneal astigmatism greater than 0.75 D.
Phacoemulsification with bilateral implantation of the 1stQ Comfort Z-EDOF refractive EDOF IOL in the capsular bag. Toric variant used for preoperative corneal astigmatism greater than 0.75 D.
Time frame: 6 months after surgery
Maximum contiguous defocus span (in diopters) over which monocular distance-corrected visual acuity remains ≤0.2 logMAR, derived from a standardized defocus curve (4 m ETDRS chart; +1.0 D to -3.5 D in 0.5 D steps).
Time frame: 6 months after surgery
logMAR acuity: UDVA and CDVA (4 m); UIVA at 66 cm and 80 cm and DCIVA (intermediate); UNVA at 40 cm and DCNVA (near).
Contact information is provided by the study sponsor or research team.
Vienna Hospital Association
Other Gov
Acronym: 1stQvsPureSee
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07722247
Astigmatism, Cataract
Split, Splitsko-dalmatinska County, Croatia
View Trial DetailsNCT07719101
Cataract, Exfoliation Syndrome
Split, Splitsko-dalmatinska County, Croatia
View Trial DetailsNCT07715071
Cataract, Eye Diseases
View Trial DetailsNCT07713069
Cataract, Eye Diseases
View Trial Details