Mercy Medical Center
Baltimore, Maryland, 21202, United States
NCT Number: NCT02769442
A randomized prospective comparison of two FDA approved intravenous catheters in the emergency department setting. The Terumo SurFlash Plus offers novel technologies that promise to increase intravenous access success rates and decrease blood contamination of the insertion site. This study would analyze these properties in our busy, urban emergency department setting where time and safety of intravenous access are most critical.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Baltimore, Maryland, 21202, United States
Rational for the Study Emergency department (ED) patients frequently require rapid, short-term intravenous (IV) access for diagnosis and treatment of emergency medical conditions. IV access can be uncomfortable and painful for the patient. Therefore ensuring first attempt success is important. Furthermore, given the time-sensitive nature of emergent medical conditions, immediate success helps to minimize delay in analgesic medication administration, resuscitation and therapeutic interventions. The process of obtaining IV access has the potential for operator exposure to blood-borne pathogens. After a tourniquet is placed on an extremity, positive venous pressure forces blood out of the catheter until a lure lock can be applied. Traditional IV catheters require the operator to kink the catheter and apply pressure to the body of the catheter to mitigate the degree of blood leakage while simultaneously connecting the lure lock. This is a complicated process that often leads to blood contamination of the insertion site, and the environment, including the potential for blood spillage on the bedding, ground or the operator. In addition to the potential for blood-born pathogen exposures, this spillage leads to further patient care delays, as it requires prompt cleaning.
Terumo Medical Corp., a leading manufacturer of medical devices, has introduced a novel IV access catheter (which is already FDA approved) with features that promise to increase first attempt success and decrease blood contamination during the insertion process. The Terumo SurFlash Plus catheter has a technology that produces a visible flash of blood at the end of the catheter when the needle is placed in the vessel and a second flash between the catheter and the needle which confirms proper catheter placement in the vein. Furthermore, this new catheter has a proprietary safety valve that minimizes the risk of blood exposure between needle removal and IV lure lock attachment.
This study would analyze these unique properties (first skin puncture success and insertion site blood contamination) in a high volume, urban emergency department where time and safety of IV access are critical.
Purpose of Study Primary Objective: Compare the rate of first-skin puncture success using the Terumo SurFlash Plus compared with the BD Insyte Autoguard.
Secondary Objective: Compare the frequency and severity of blood contamination of the insertion site between the two aforementioned devices.
Research Design This will be a prospective, randomized controlled study of the Terumo SurFlash Plus IV catheter versus the current standard ED IV catheter (BD Insyte Autoguard).
Study device: The Terumo SurFlash Plus catheter is FDA approved and already used at multiple medical centers in the United States. Gauge sizes 18, 20 and 22 will be provided by TERUMO to the ED at no cost to the hospital.
IV inserters (operators) will be Mercy Medical Center emergency department technicians, nurses and providers who routinely obtain IV access in the ED.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: Within first minute of IV access
Time frame: Within first minute of IV access
Compare the frequency of bleeding near the insertion site
University of Maryland, Baltimore
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06851585
Catheterization, Catheterization, Peripheral
Poitiers, France
View Trial DetailsNCT07519304
Bites and Stings, Cardiovascular Diseases
View Trial DetailsNCT07006038
Catheter Complications, Catheterization, Peripheral
Izmir, Turkey (Türkiye)
View Trial DetailsNCT04499638
Cardiovascular Diseases, Catheter-Related Infections
Barcelona, Spain
View Trial Details