Skip to main content
OpenTrials
Recruiting

NCT Number: NCT07287176

Prospective Evaluation of the Pulse Biosciences nPulse™ Vybrance™ Percutaneous Electrode System

The primary objective of this study is to reproduce in a multi-center study results obtained during the feasibility First-In-Human (FIH) study with Prof. Stefano Spiezia, MD (Ospedale del Mare, Naples, Italy) and to monitor additional thyroid-related symptoms and impact of patients quality of life post-ablation using a validated QoL questionnaire.

Recruiting

Interested in participating?

Request Info

Key information

Age range

22 year–80 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Sarasota Memorial Hospital, Sarasota, Florida, United States

Loading trial locations.

About this study

The study design is a prospective, non-randomized, clinical study using the Pulse Biosciences nPulse Vybrance Percutaneous Electrode (PE) System for the treatment of benign thyroid nodules (BTNs) using nanosecond Pulsed Field Ablation (PFA). All participants will receive at least one nsPFA treatment and may be eligible to receive a second treatment at the 6-month follow up visit per physician discretion. All participants will have regularly scheduled ultrasound assessments and administration of questionnaires (e.g., Thy-PRO39 and SF-12) at 1-month, 3 months, 6 months and 12 months post-nsPFA treatment.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Participant is willing and able to provide voluntary, written informed consent to participate in this study and from whom written informed consent has been obtained
  • Participants must be willing and able to comply with study procedures including all follow-up visits
  • Selected nodule is amenable to trans-isthmus approach
  • Nodule is confirmed as benign based on results from one or more of the following diagnostic tests:
  • (Bethesda II) on at least 2 ultrasound guided fine needle aspirations (FNA) or core needle biopsy (CNB);
  • A single benign diagnosis of FNA or CNB when the nodule has benign ultrasound features [American College of Radiology (ACR) Thyroid Imaging Reporting & Data System [TI-RAD] TR 1-3, American Thyroid Association [ATA] very low suspicion];
  • Candidate has a hyperfunctional nodule following 1 ultrasound guided FNA or CNB with or without molecular testing; or
  • Benign (Bethesda III or IV) with two biopsies in addition to molecular testing confirming benign diagnosis
  • Selected nodule is <80.0 ml
  • Participant has normal vocal cord mobility by ultrasound evaluation
  • Participant has presence of compression symptoms, cosmetic concerns or anxiety for which participant requests treatment of the benign thyroid nodule
  • Participant has a solitary thyroid nodule or dominating nodule that is well-defined in multinodular goiter

Exclusion criteria

  • Participant has an implantable electronic medical device. (i.e., pacemaker, implantable cardioverter defibrillator)
  • Participant has cystic nodules (< 70% solid components)
  • Participant has calcified nodules
  • Participant is known to be immune compromised
  • Participant had previous neck irradiation
  • Participant has abnormal cervical lymph nodes present during screening visit examination
  • Participant has history of familial thyroid cancer in more than two first-degree relatives
  • Selected nodule previously treated with radiofrequency ablation or ethanol. This does not apply to nodules previously treated with nanosecond Pulsed Field Ablation (nsPFA)
  • Participants currently suffering from a hematological disease or bleeding tendency
  • Selected nodule likely to be in contact with the recurrent laryngeal nerve on ultrasound evaluation
  • Participant has a history of uncontrolled cardiac arrhythmia, uncontrolled hypertension, chronic liver disease or chronic kidney disease (Stage 4-5), or recent history of myocardial infarction or structural heart disease as determined by the Investigator
  • Participant has abnormal contralateral vocal cord function
  • Anesthesia drug allergies
  • Participant is pregnant at the time of screening or within 30 days prior to enrollment
  • Participant has any condition or situation which, in the Investigator's opinion, puts the participant at significant risk, could confound the study results, or may interfere significantly with the participant's participation in the study
  • Use of any investigational device or drug within 30 days prior to enrollment that may confound the results of this study

Treatment and study plan

nPulse Vybrance Percutaneous Electrode System

Device

The nPulse Vybrance procedure will be performed under ultrasonographic guidance using a local anesthetic at the intended puncture site and all participants will receive general anesthesia in the operating room. The targeted thyroid nodule will be treated within a customized treatment level (DEFAULT) programmed on the Console. The Investigator will treat the entire nodule while protecting from ablation to any surrounding vital structures to prevent serious adverse events throughout the procedure. Any procedural adverse events will be documented, as applicable.

Primary outcomes

  1. Volume Reduction Ratio (VRR)

    Time frame: 6 months post-index procedure

    The percentage decrease of thyroid nodule volume measured by ultrasonography after treatment (ablation) using the nPulse Vybrance Percutaneous Electrode System

Secondary outcomes

  1. Volume Reduction Ratio (VRR) Over Time

    Time frame: 1 month, 3 months, 6 months and 12 months post-nPulse Vybrance treatment

    The percentage decrease of thyroid nodule volume measured by ultrasonography after treatment (ablation) at various time points post-ablation using the nPulse Vybrance Percutaneous Electrode System

  2. Recurrence Rate

    Time frame: 6 and 12 months post-nPulse Vybrance treatment

    The number of participants who experience nodule recurrence in same location of treatment post-nPulse Vybrance index procedure

Study contacts

Contact information is provided by the study sponsor or research team.

Ioana Gruchevska

CONTACT

[email protected]

(314) 484-7033

William A. Knape

CONTACT

[email protected]

9197572033

Sponsors and collaborators

Lead sponsor

Pulse Biosciences, Inc.

Industry

Registry information

Official study title

Prospective Evaluation of the Pulse Biosciences nPulse™ Vybrance™ Percutaneous Electrode System in Symptomatic Benign Thyroid Nodules (PRECISE-BTN) Study

Acronym: PRECISE-BTN

Important dates

Study start
2025
Primary completion
2026
Study completion
2027
First posted
Dec 17, 2025
Registry last updated
Apr 15, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.