Skip to main content
OpenTrials
Completed

NCT Number: NCT01718470

Proseal Laryngeal Mask Airway or Endotracheal Tube for Emergence From Neuroanesthesia

Extubation and emergence from anesthesia lead to systemic and cerebral hemodynamic changes that can cause cerebral edema and hemorrhage. The hemodynamic profile on emergence is more favorable if a laryngeal mask airway (LMA) is inserted before neurosurgical patients emerge from anesthesia. We aimed to compare the impact of awakening neurosurgery patients after insertion of a ProSeal LMA to replace the endotracheal tube (ETT).

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Anesthesia department, Hospital Clínic de Barcelona

Barcelona, 08036, Spain

About this study

At the end of surgery, the anesthesiologist opened a sealed envelope labeled with software-generated randomized numbers to learn the patient's assignment to one of two groups to emerge from anesthesia with the ETT still in place or after it had been replaced by an LMA.

Hemodynamic variables were recorded at 8 moments: baseline, in the operating room one minute before anesthetic induction; 5 minutes after the end of surgery before awakening (ETT group) or before tube replacement (LMA group); and 1, 5, 10, 15, 30 and 60 min after extubation or LMA removal (according to group assignment).

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Elective craniotomy

Exclusion criteria

  • Difficult airway
  • Uncontrolled hypertension before surgery
  • gastroesophageal reflux

Treatment and study plan

Endotracheal tube

Procedure

Hemodynamic variables were recorded at 8 moments: baseline, in the operating room one minute before anesthetic induction; 5 minutes after the end of surgery before awakening (ETT group) and 1, 5, 10, 15, 30 and 60 min after extubation . The last blood pressure and heart rate measurements were taken in the postoperative recovery room.

LMA

Procedure

Hemodynamic variables were recorded at 8 moments: baseline, in the operating room one minute before anesthetic induction; 5 minutes after the end of surgery before tube replacement (LMA group); and 1, 5, 10, 15, 30 and 60 min after LMA removal. The last blood pressure and heart rate measurements were taken in the postoperative recovery room.

Other names: Laryngeal mask

Primary outcomes

  1. systolic blood pressure change

    Time frame: 1 minute before anesthesia induction, 5 minutes before extubation, and minute 1, 5, 10, 15, 30 and 60 after extubation

Secondary outcomes

  1. heart rate change

    Time frame: 1 minute before anesthesia induction, 5 minutes before extubation, and minutes 1,5,10,15,30 and 60 after extubation

Other outcomes

  1. Norepinephrine plasma concentration change

    Time frame: 1 minute before anesthesia induction, 1 minute and 30 minutes after extubation,

Sponsors and collaborators

Lead sponsor

Ricard Valero

Other

Collaborators

  • Fundacion Clinic per a la Recerca Biomédica

Registry information

Official study title

Proseal Laryngeal Mask Airway Attenuates Systemic and Cerebral Hemodynamic Response During Awakening of Neurosurgical Patients

Important dates

Study start
2011
Primary completion
2011
Study completion
2012
First posted
Oct 31, 2012
Registry last updated
Oct 31, 2012

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.