Skip to main content
OpenTrials
Not Yet Recruiting

NCT Number: NCT06735196

Profiling the Variation of Microbiome Along the Intestinal Tract Based on Sampling Capsule Endoscopy

Intestinal flora and metabolites are associated with multiple systemic diseases. Current approaches for acquiring information regarding microbiota/metabolites have limitations. We aimed to develop a precise sampling capsule endoscopy (SCE) for the convenient, non-invasive, and accurate acquisition of digestive bioinformation for disease diagnosis and evaluation. The SCE was used for sampling jejunum, ileum, and colon content in healthy volunteers. The GI liquid was then used for microbiome profiling and metabolomics profiling. In this study, we aimed to describe the characteristics and functions of key microflora in the whole intestinal microenvironment of healthy volunteers.

Not Yet Recruiting

Trial opening soon.

Get Notified

Key information

Age range

18 year–80 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

First Affiliated Hospital of Naval Medical University (Changhai Hospital)

Shanghai, Shanghai Municipality, 200433, China

About this study

Gut microorganisms involved in human food digestion, immune system regulation, and protection against pathogens are critical in maintaining health. Gut microorganism dysbiosis influences the course of gastrointestinal disease and cardiovascular, neurological, metabolic diseases, and other disorders. Therefore, a deeper understanding of gut microorganisms is indispensable in researching human disorders. However, current sampling methods, including fecal microbial examination, breath hydrogen testing, and invasive endoscopy acquisition, fail to obtain local gut microbiome samples under its chemical environment in natural and unperturbed states. A comfortable, non-invasive, and precise regional intestinal fluid collection device is needed.

Recently, novel ingestible devices have collected intestinal fluids from animals' and humans' jejunum, ileum, and colon. Significant differences between bacteria and metabolites in the intestines versus stool have been identified, showing the spatiotemporal structure of the gastrointestinal microbiome and metabolome. Compared with saliva and stool samples, ingestible devices acquired samples in an environment resembling nature, which is more reliable in explaining the association between gut microorganisms dysbiosis and various disorders.

However, current ingestible sampling devices still have several limitations. Therefore, a novel sampling capsule endoscopy (SCE) system was developed. This novel SCE can precisely and efficiently acquire intestinal bio information through direct visualization under electric control. This study aims to collect fluids from different segments of the gastrointestinal tract using the SCE system to clarify the differences in the distribution of gut microorganisms in different areas in healthy volunteers and patients with inflammatory bowel disease or colon cancer.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Male or female, age ≥18 years and ≤80 years;
  • American Society of Anesthesiologists (ASA) physical health risk level 1;
  • Good overall health, no clinically significant medical history;
  • No clinically significant signs were found in the physical examination;
  • For women of fertility, the urine pregnancy test was negative within 7 days after the screening visit, and they were willing to take contraceptive measures throughout the study;
  • Willing to provide blood samples, stool samples, urine samples, saliva samples, and intestinal fluid samples, and agree that the samples provided will be stored for a long time and used for research purposes.
  • Agree to avoid strenuous activities during the participation in this clinical trial;
  • Agree to participate in this clinical trial and sign the informed consent form.

Exclusion criteria

  • Patients with digestive tract diseases such as cancer, inflammatory bowel disease, achalasia, esophageal diverticulum, etc.;
  • Patients who have participated in other clinical trials within three months or are currently participating in other clinical trials;
  • Patients currently use medication for other diseases or plan to use medication for treatment;
  • Patients who have used antibiotics within three months;
  • Patients with known or suspected gastrointestinal obstruction, stenosis, diverticulum, and fistula;
  • Patients with swallowing disorders;
  • Pregnant or lactating women or women who plan to become pregnant within 30 days of the visit period;
  • Patients who are not suitable for surgery or refuse to undergo any abdominal surgery (once the capsule is retained, it cannot be removed by surgery);
  • Patients with any form of active substance abuse or dependence (including drug or alcohol abuse), any unstable physical or mental illness, any malignant lesions in any location or system, or any chronic disease that the researcher believes may interfere with the study;
  • The researcher believes any other factors are unsuitable for selection or affect the subject's participation in the study.

Treatment and study plan

sampling capsule endoscopy

Device

Healthy volunteers swallowed SCEs to collect intestinal fluids in different intestinal areas. When SCEs excreted, the fluids inside SCEs would be collected for microbiome and metabolome analysis.

Primary outcomes

  1. The feasibility of sampling capsule endoscopy system in collecting fluids from different intestinal segments in healthy volunteers

    Time frame: two weeks

    The total successful rate of SCE in sampling fluids in intestinal segments. A successful sampling procedure conducted by SCE was defined when the following conditions were met simultaneously: 1) accurately recognization of target intestinal areas. 2) the intestinal liquid can be successfully collected in the sampling chamber.

Secondary outcomes

  1. Standard gastrointestinal preparation procedure

    Time frame: two week

    To select the best standard gastrointestinal preparation procedure which makes the visualization score under SCE graded as the best (on a scale of 1 to 5; 1, the worst; 5, the best) .

  2. Sampling time

    Time frame: two weeks

    The total time for sampling intestinal fluids of a SCE.

  3. Sampling volume

    Time frame: two weeks

    The overall volume of samples obtained by a SCE during a single examination.

  4. Number of sampling times

    Time frame: two weeks

    Times we tried to sample during a single SCE examination.

  5. Safety analysis

    Time frame: from enrollment to the end of follow-up at 30 days

    All adverse events occurring during the study

Study contacts

Contact information is provided by the study sponsor or research team.

Chen He, Doctor

CONTACT

[email protected]

86+021 31162770

Xi Jiang, Doctor

CONTACT

[email protected]

86+021 31162770

Sponsors and collaborators

Lead sponsor

Changhai Hospital

Other

Registry information

Official study title

Profiling the Variation of Microbiome Along the Intestinal Tract Based on Sampling Capsule Endoscopy: a Feasibility and Safety Study

Important dates

Study start
2024
Primary completion
2025
Study completion
2026
First posted
Dec 16, 2024
Registry last updated
Dec 16, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.