Sleep Disorders Clinic
Halifax, Nova Scotia, B3H 2E2, Canada
NCT Number: NCT04873024
The standard for treatment for people suffering from obstructive sleep apnea (OSA) syndrome involves the use of Continuous, or Automatic Positive Airway Pressure (CPAP, APAP) machines, which work by delivering air via tubing and mask to a patient at pressures of up to 20cmH2O. This increased pressure is meant to stabilize the airway to reduce obstruction events. APAP machines are generally more effective and more comfortable for patients than CPAP machines because these devices automatically adjust pressure to treat an apnea. However, this treatment is reactive and often ineffective since the necessary pressure is applied seconds after breathing has already stopped; The results of a previous study performed showed strong indications for predicting an apnea before it occurs using measurements collected by existing sensors of the CPAP and APAP machines. If apnea events can be predicted before they occur, the air pressure required to treat them could be supplied ahead of time, preventing the apnea from occurring.
The hypothesis to be tested is whether obstructive sleep apnea events can be prevented, by predicting their onset ahead of time and adjusting the airway pressure accordingly.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Halifax, Nova Scotia, B3H 2E2, Canada
Patients recruited for the study will undergo two different PAP therapy treatments during sleep: a control treatment and an intervention treatment. Both types of treatment will be delivered using a positive airway pressure (PAP) device with an Investigational Testing Authorization (ITA) from Health Canada (HC). This medical device consists of a commercially available PAP device which has been integrated with a feature to communicate with a computer hosting the predictive software via USB. Using signals received from the PAP device, the software can predict incoming apneas and direct the PAP machine to increase pressure for a short period of time; This study has been designed as a single-blind, randomised crossover study, in which recruited patients who suffer from Obstructive Sleep Apnea (OSA) will undergo at least two sleep studies. During a sleep study, the patient will spend a night of sleep at the sleep clinic (Sleep Disorders Clinic, QEII Abbie J. Lane Memorial Building) and receive one of two PAP therapy treatments; For the control treatment, the PAP device will deliver standard PAP therapy treatment to the patient; For the intervention treatment, the PAP device will deliver the standard PAP therapy treatment in addition to intervention when an apnea is predicted; All recruited participants will undergo at least two study nights and receive both treatments at least once; For all study night, standard Polysomnography (PSG) measurements will also be acquired (breathing rate, brain waves, movement, blood rate, oxygen levels, etc.); Participants will not be told what therapies are being used for each night, and the device used will be concealed from their view; After each night, participants will be asked to fill out a Satisfaction/Adherence questionnaire.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
All participants currently screened, enrolled, and consented who have not yet had all overnight testing done, AND who have an OAI < 3.0 and AHI < 5.0, will be excluded from the study, as this group has been fully enrolled to date.
Breathing data collected by the device will be processed by a machine learning algorithm to predict obstructive apnea events. When obstructive apnea events are predicted, the algorithm triggers the CPAP device to respond to the apnea event ahead of its onset.
For the control treatment, the device will operate as its conventional treatment.
Other names: Proactive airway management
Time frame: 2 nights (approx. 8hrs/night)
To be measured via Polysomnography (PSG) data, which are standard measures obtained in sleep studies. AHI is measured as the average number of Apnea and Hypopnea occurrences in an hour during sleep (units: events/hour).
Time frame: 2 nights (approx. 8hrs/night)
To be measured via Polysomnography (PSG) data, which are standard measures obtained in sleep studies. OAI is measured as the average number of exclusively Obstructive Apnea occurrences in an hour during sleep (units: events/hour).
Time frame: 2 nights (approx. 8hrs/night)
To be measured via Polysomnography (PSG) data, which are standard measures obtained in sleep studies.
RDI is measured as the average number of Apneas, Hypopneas and RERAs (Respiratory Effort Related Arousal) occurrences in an hour during sleep.
Time frame: 2 nights (approx. 8hrs/night)
The ODI metric is also obtained through Polysomnography (PSG) data. ODI is measured as the average number of times per hour of sleep that the blood's oxygen level drop by a certain degree from baseline (units: events/hour).
Time frame: 2 nights (approx. 8hrs/night)
Another objective will be the comparison of patient satisfaction after each night of sleep, which will be scored and quantified by an adherence/satisfaction questionnaire to determine whether the use of our device had a positive, or neutral effect on their sleep.
The questionnaire will be given to participants to fill out after treatment.
Questionnaire responses will be scaled to an Adherence score using a 11-point Likert rating scale. Higher scores indicate higher participant's adherence/satisfaction to the treatment.
NovaResp Technologies Inc
Industry
Real-time Prediction and Prevention of Apnea Events on PAP Machines in an Interventional Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03034447
Apnea, Apnea, Sleep
São Paulo, Brazil
View Trial DetailsNCT01719224
Airway Obstruction, Apnea
Boston, Massachusetts, United States
View Trial DetailsNCT00205543
Airway Obstruction, Apnea
Richmond, Virginia, United States
View Trial DetailsNCT07259200
Airway Obstruction, Apnea
Grodzisk Mazowiecki, Poland
View Trial Details