SAPIEN XT NovaFlex delivery system
DeviceTranscatheter aortic valve implantation via transfemoral approach.
Other names: SAPIEN XT, NovaFlex delivery system
NCT Number: NCT01419015
A single arm, prospective multicenter non-randomized pivotal clinical trial evaluating the 20mm Edwards SAPIEN XT™ transcatheter heart valve (model 9300TFX), NovaFlex™ transfemoral delivery system, and crimper accessories. The trial includes a premarket pivotal cohort to evaluate the system performance as well as a post market clinical follow-up phase involving long term follow-up of all patients to evaluate the safety of investigational devices up to 5 years.
Looking for future studies?
Notify Me19 year and older
All sexes
Interventional
Not applicable
Kokura Memorial Hospital, Kitakyushu, Fukuoka, Japan
Purpose: To evaluate the safety and efficacy of THV-9300 (20mm) for patients who have severe symptomatic aortic stenosis attributed to calcification and degeneration of a valve leaflet and for whom undergoing a surgery safely would be difficult.
Enrollment: 15 patients (No.of patients needed: 12)
Follow-up: Subject data collection will include clinical information at baseline and during the index procedure. Subjects will undergo clinical follow-up at discharge, 30 days, 6 months and annually for 5 years.
Clinical sites:
1)Osaka University Hospital, 2)Kurashiki Central Hospital, 3)Sakakibara Heart Institute, 4) Kokura Memorial Hospital
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Transcatheter aortic valve implantation via transfemoral approach.
Other names: SAPIEN XT, NovaFlex delivery system
Time frame: 1 year
Improvement of the aortic valve area (AVA) and New York Heart Association (NYHA) functional classification from baseline to 1 year after the procedure. NYHA functional classification of heart failure based on how much a patient is limited during physical activity. The rating ranges from I-IV, with the lowest (I) as no limitations and the highest (IV) unable to carry on any physical activity without discomfort. The AVA at 1 year >= 0.65 cm2 indicates improvement. This outcome measure shows the percentage of patients that had an improvement in both NYHA Class and AVA. Note: One patient did not complete a 6-month echo.
Edwards Lifesciences
Industry
A Clinical Trial of a 20mm Transcatheter Bioprosthetic Valve for Patients With Aortic Stenosis
Acronym: PREVAIL-20J
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT00820599
Aortic Valve Disease, Aortic Valve Stenosis
Aalst, Belgium
View Trial DetailsNCT01113983
Aortic Valve Disease, Aortic Valve Stenosis
Kurashiki, Okayama-ken, Japan
View Trial DetailsNCT02833948
Aortic Valve Disease, Aortic Valve Stenosis
Los Angeles, California, United States
View Trial DetailsNCT02394184
Aortic Valve Disease, Aortic Valve Stenosis
Seoul, South Korea
View Trial Details