Zhongshan Hospital
Shanghai, Shanghai Municipality, China
NCT Number: NCT04582877
Patients with intermediate-grade coronary stenosis undergo measurement of fractional flow reserve using the test article (Zurich Pressure Guidewire System) and predicate article (Abbott PressureWire System). Both articles are used within the same participant and the FFR values are statistically compared with each other.
Looking for future studies?
Notify Me18 year–75 year
All sexes
Interventional
Not applicable
Shanghai, Shanghai Municipality, China
The objective of the 'Pressure guidewire system multi-center, prospective, single-subject design clinical trial' is to evaluate the effectiveness and safety of Zurich Medical's pressure guidewire system (including guidewire with high-fidelity sensors and a unique paired portable display unit), which is used to measure the coronary artery blood fractional flow reserve (FFR) to diagnose coronary artery disease, and to direct a catheter through a blood vessel. This clinical trial uses a multi-center, prospective, single-subject design trial method, using St. Jude Medical's pressure guidewire and Analyzer Express as a control device. The subjects who met the criteria for this study will be registered with the central registration system after enrollment. Participants with intermediate-grade coronary stenosis undergo measurement of fractional flow reserve using the test article (Zurich Pressure Guidewire System) and predicate article (Abbott PressureWire System). Both articles are used within the same participant and the FFR values are statistically compared with each other. The subject's FFR of coronary artery stenosis will first be measured using investigational device and recorded, and then measured using control device and recorded. The safety follow-up period is 48 hours.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
FFR is measured sequentially with the test article and the predicate device.
Time frame: Acute - all measurements are taken and assessed during each procedure. Each participant completes their procedure in one visit, with each procedure taking up to 30 minutes.
Diagnostic consistency rate: When the measurement of control device is positive (FFRPW ≤ 0.80) or negative (FFRPW > 0.80), investigational device is also positive (FFRWS ≤ 0.80) or negative (FFRWS > 0.80).
Each subject will be considered a research unit (for patients with multiple lesions, the method of converting the results of multiple lesions into patient level is defined in the statistical analysis plan), and the coronary artery FFRPW measured by control device will be taken as reference.
Measurements are taken on patients with both the trial device and control device, sequentially during the same visit.
Time frame: Acute - all measurements are taken and assessed during each procedure. Each participant completes their procedure in one visit, with each procedure taking up to 30 minutes.
After all subjects complete their procedures, using the subjects as the research unit, with the control device's determined coronary artery FFRpw as a reference, and with FFRpw ≤ 0.80 as a positive threshold, the sensitivity of diagnosing coronary heart disease using the trial device is calculated. Sensitivity = Number of subjects with FFRws (≤0.80) / Number of subjects with FFRpw (≤0.80).
Measurements are taken on patients with both the trial device and control device, sequentially during the same visit.
Time frame: Acute - all measurements are taken and assessed during each procedure. Each participant completes their procedure in one visit, with each procedure taking up to 30 minutes.
After all subjects complete their procedures, using the subjects as the research unit, with the control device's determined coronary artery FFRpw as a reference, and with FFRpw ≤ 0.80 as a positive threshold, the specificity of diagnosing coronary heart disease using the trial device is calculated. Specificity = Number of subjects with FFRws (>0.80) / Number of subjects with FFRpw (>0.80).
Measurements are taken on patients with both the trial device and control device, sequentially during the same visit.
Time frame: Acute - all measurements are taken and assessed during each procedure. Each participant completes their procedure in one visit, with each procedure taking up to 30 minutes.
using the subjects as the research unit, with the control device's determined coronary artery FFRpw as a reference, and with FFRpw ≤ 0.8 as a positive threshold, the positive predictive value of diagnosing coronary heart disease using the trial device is calculated.
PPV = true positive / (true positive + false positive)
Measurements are taken on patients with both the trial device and control device, sequentially during the same visit.
Time frame: Acute - all measurements are taken and assessed during each procedure. Each participant completes their procedure in one visit, with each procedure taking up to 30 minutes.
After all subjects complete their procedures, using the subjects as the research unit, with the control device's determined coronary artery FFRpw as a reference, and with FFRpw ≤ 0.8 as a positive threshold, the negative predictive value of diagnosing coronary heart disease using the trial device is calculated.
NPV = true negative / (true negative + false negative)
Measurements are taken on patients with both the trial device and control device, sequentially during the same visit.
Time frame: Acute - all measurements are taken and assessed during each procedure. Each participant completes their procedure in one visit, with each procedure taking up to 30 minutes.
On a two-dimensional coordinate graph, set the x-axis as the false positive rate (FPR), and the y-axis as the true positive rate (TPR). For the FFRws values measured by the trial device, a point pair of TPR and FPR can be obtained based on its performance on the test sample. Adjust the diagnostic threshold of FFRws to obtain a series of points, connect them in sequence (including the points (0,0) and (1,1)), which forms the ROC curve of FFRws. The value of Area Under Curve (AUC) is the size of the area under the ROC curve. The curve is plotted using MedCalc software.
Measurements are taken on patients with both the trial device and control device, sequentially during the same visit.
Time frame: Acute - all measurements are taken and assessed during each procedure. Each participant completes their procedure in one visit, with each procedure taking up to 30 minutes.
Using the vessel as the research unit, with the trial device's measured coronary artery FFRws value as the y-axis, and the control device's measured coronary FFRpw value as the x-axis, perform linear regression analysis on the FFR measurement results, and record the regression analysis equation, slope, and intercept. The analysis will be conducted at the lesion level.
Regression analysis equation: Y=aX + b
Measurements are taken on patients with both the trial device and control device, sequentially during the same visit.
Time frame: Acute - all measurements are taken and assessed during each procedure. Each participant completes their procedure in one visit, with each procedure taking up to 30 minutes.
Bland-Altman analysis is a statistical method for evaluating the agreement between two measurement methods and for assessing bias.
Using the vessel as the research unit, analyze the trial device's measured coronary artery FFRws value and the control device's measured coronary artery FFRpw value using Bland-Altman analysis, and plot the bias graph. Measurements are taken on patients with both the trial device and control device, sequentially during the same visit.
In the two-dimensional Cartesian coordinate of the bias graph, the x-axis represents the average value of the FFR measured by the two devices for each diseased vessel, and the y-axis represents the difference between the FFR values determined by the two devices for each diseased vessel.
mean: (x-axis): (FFRws+FFRpw) / 2 absolute error (y-axis): FFRws - FFRpw
The mean absolute error can then be calculated by taking the average of all absolute errors.
Time frame: Acute - all measurements are taken and assessed during each procedure. Each participant completes their procedure in one visit, with each procedure taking up to 30 minutes.
After all subjects complete their procedures, using the vessel as the research unit, perform Pearson linear correlation analysis on the trial device's measured coronary artery FFRws value and the control device's measured coronary artery FFRpw value, and record the correlation coefficient.
The correlation coefficient is a statistical measure that determines the strength of a linear relationship between two variables, ranging from -1 to 1. A value close to 1 represents a strong positive correlation between the x and y axis values (trail device FFRws and control device FFRpw). Because of the nature of this value, the measure type is "number".
The coefficient is determined using the following formula:
P = Cov(x,y) / OxOy
where: Cov(x,y) = covariance of variables x and y Ox = standard deviation of x Oy = standard deviation of y
Time frame: Acute - all measurements are taken and assessed during each procedure. Each participant completes their procedure in one visit, with each procedure taking up to 30 minutes.
After all subjects complete their procedures, using the vessel as the research unit, with valid FFRws and FFRpw readings as the standard for successful device use, compare the device success rates of the trial device and the control device. Success rate is determined as the number of units that were performed successfully on the patient. The case was deemed successful if the unit was able to read a valid FFRws and FFRpw reading.
Measurements are taken on patients with both the trial device and control device, sequentially during the same visit.
Zurich Medical Inc.
Industry
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05584280
Cardiovascular Diseases, Heart Diseases
Gothenburg, Sweden
View Trial DetailsNCT02694185
Behavior, Cardiovascular Diseases
San Francisco, California, United States
View Trial DetailsNCT06345573
Behavior, Behavioral Symptoms
Zurich, Canton of Zurich, Switzerland
View Trial DetailsNCT03253692
Arterial Occlusive Diseases, Arteriosclerosis
Lexington, Kentucky, United States
View Trial Details