It is well known, that patients with circulatory impairment sometimes, but not always, benefit from intravenous fluids. Predicting if a fluid administration will improve circulation is therefore of substantial clinical interest.
Ventilator treatment induces cyclic variation in blood pressure due to interaction between the lungs and the heart. This variation is minor, but its amplitude may be used for guiding fluid administration.
However, this method of using ventilator-induced variation in blood pressure to predict the effect of fluid administration was developed when different settings for ventilator treatment was recommended, compared with today. With today's recommend ventilator treatment, the method is, unfortunately, less reliable.
The investigators will investigate how different ventilator settings influence variation in blood pressure, and the investigators will test if this knowledge allows us to better predict the effect of a fluid administration, by taking the ventilator settings into account.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Aarhus N, 8200, Denmark
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Before a planned fluid administration, the investigators will apply a series of 10 ventilator settings for 30 seconds each.
The settings are the following combinations of respiratory rate (RR) and tidal volume (TV):
RR (min^-1), TV (ml/kg predicted body weight)
31, 6
31, 8
24, 6
24, 8
17, 6
17, 8
10, 4
10, 6
10, 8
10, 10
(the order of the respiratory rates: 17 to 31, will be randomized. 10/min will always be last. Tidal volume is always applied from lowest to highest for each respiratory rate).
Time frame: From two minutes before to two minutes after a fluid administration.
A patient is considered a fluid responder if they have a >10% increase in stroke volume (pulse contour analysis by the Edwards EV1000 with a FloTrac sensor).
Pre-fluid stroke volume is calculated as the median stroke volume estimate in the two minutes immediately preceding the fluid bolus.
Post-fluid stroke volume is calculated as the median stroke volume estimate in the two minutes immediately following the fluid bolus.
Change in stroke volume is calculated as: 100% * (Post-fluid stroke volume - Pre-fluid stroke volume) / Pre-fluid stroke volume
University of Aarhus
Other
Fluid Responsiveness Prediction Using Pulse Pressure Variation - Integrating Ventilator Settings
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02679625
Edema, Fluid Overload
Sylmar, California, United States
View Trial DetailsNCT02813915
Edema, Fluid Overload
View Trial DetailsNCT02903316
Arterial Occlusive Diseases, Arteriosclerosis
Aarhus N, Denmark
View Trial DetailsNCT07192523
Edema, Hypervolemia
Istanbul, Kartal, Turkey (Türkiye)
View Trial Details