Skip to main content
OpenTrials
Completed

NCT Number: NCT02381509

Predicting the Safety and Effectiveness of Inferior Vena Cava Filters

PRESERVE is a multi-center, prospective, open-label, non-randomized investigation of commercially available IVC filters from 6 manufacturers placed in subjects for the prevention of pulmonary embolism (PE). This study will enroll up to 1,800 IVC filter subjects (with a maximum of 300 subjects per IVC filter brand) at up to 60 sites in the US. The primary objective of this investigational device exemption (IDE) clinical investigation is to evaluate the safety and effectiveness of the commercially available IVC filters (retrievable and permanent) in subjects with clinical need for mechanical prophylaxis of PE with an IVC filter.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

University of Arkansas, Little Rock, Arkansas, United States

Loading trial locations.

About this study

The overall goal is to characterize the current practice of IVC filter placement, including the indications, filter type, frequency and success of filter removal, safety of placement initially and in the long term, including filter mechanical stability and caval patency, and the frequency of subsequent episodes of PE and recurrence of DVT. The first steps are to identify the characteristics of use in a broad range of clinical practice settings in the US.

Commercially available IVC filters from 6 manufacturers in the United States will be used. The type of FDA-cleared IVC filter implanted will be left to the discretion of the Principal Investigator at the Site. The following IVC filters will be utilized in this trial:

  • ALN Vena Cava Filter (with and without hook) (ALN Implants Chirurgicaux)
  • Option™ Elite Retrievable Vena Cava Filter (Argon Medical Devices Inc., designed and manufactured by Rex Medical)
  • VenaTech® LP Vena Cava Filter (B Braun Interventional Systems, Inc.) and VenaTech® Convertible™ Vena Cava Filter
  • DENALI® Vena Cava Filter System (DL900F, DL900J) (Bard Peripheral Vascular, Inc.)
  • Cook Günther-Tulip™ Vena Cava Filter (Cook Incorporated)
  • Cordis OPTEASE® Retrievable Vena Cava Filter and Cordis TRAPEASE® Permanent Vena Cava Filter (Cordis Corporation)

Subjects will be evaluated at Procedure, Discharge, 3-months, 6-months (phone), 12-months, 18-months (phone), and 24-months post-procedure. All subjects in whom the IVC filter is removed will be followed for 1-month postretrieval. Mandated follow-up imaging will be performed at 3 months (plain film) and 12 and 24 months (contrast abdominal CT). In addition, clinical visits with physical exam will be performed at 3 months, 12 months and 24 months.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Male or Female, age 18 years or older;
  • Requires IVC filter for prevention of pulmonary embolism (PE);
  • Provide written informed consent and written HIPAA authorization prior to initiation of study procedures;
  • Willing to comply with the specified follow-up

Exclusion criteria

  • Subject is unable to participate in study evaluations pre- and post-treatment
  • Known sensitivity to contrast or serious contrast reaction such as anaphylaxis for which premedication is known to be unsuccessful in alleviating symptoms

Treatment and study plan

IVC Filter

Device

Primary outcomes

  1. Composite safety endpoint of freedom from clinically significant perforation after successful filter placement, filter embolization, caval thrombotic occlusion, deep vein thrombosis, and perioperative serious adverse event

    Time frame: Within first 365 days (± 30 days)

    Clinically significant perforation is defined as protrusion of filter legs through the wall of the IVC causing hemorrhage or hematoma or touching, impressing, or perforating another organ or that triggers the decision to remove the filter; resulting in an attempt to remove the IVC filter or requiring other intervention. Filter embolization is defined as movement of the filter or its components to a distant anatomic site completely out of the target zone after successful filter placement, confirmed by imaging. Caval thrombotic occlusion is defined as presence of an occluding thrombus in the IVC after filter insertion and documented by ultrasound (US), computed tomography (CT), magnetic resonance (MR) imaging, venography, or autopsy; this may be symptomatic or asymptomatic after successful filter placement. Deep vein thrombosis (DVT) is defined as new symptomatic DVT post-deployment, as determined by standard of care imaging. Serious adverse event is defined by ISO 14155.

  2. Composite effectiveness endpoint of procedural and technical success without occurrence of clinically significant pulmonary embolism

    Time frame: At 12-months in-situ or 1-month post-retrieval (whichever comes first)

    New symptomatic PE confirmed by appropriate imaging

Secondary outcomes

  1. Mechanical Stability

    Time frame: At 3-months, 6-months, 12-months, 18-months, 24-months or at the time of filter retrieval

    Defined by absence of: 1) Migration: cephalad movement of the filter >20mm relative to fixed anatomic landmarks compared to the time of placement, 2) Migration: caudal migration of the filter >20mm relative to fixed anatomic landmarks compared to the time of placement, 3) Perforation: >5mm outside apparent cava wall as determined by CT or perforation of adjacent viscera or major vessel, 4) Filter fracture: any loss of a filter's structural integrity (i.e. breakage or separation) documented by imaging or autopsy, 5) Filter embolization: post-deployment movement of the filter or its components to a distant anatomic site completely out of the target zone

  2. Procedure-related complications

    Time frame: At 3-months

    In the judgment of the Principal Investigator

  3. Major adverse events (composite and individual components)

    Time frame: At 3-months, 6-months, 12-months, 18-months, and 24-months

    Defined as death, PE, caval thrombotic occlusion, DVT, clinically significant perforation, retroperitoneal hematoma, or adjacent organ penetration

  4. Filter tilting >15°

    Time frame: At 3-months, 6-months, 12-months, 18-months, 24-months or at the time of filter retrieval

    As determined by appropriate imaging

  5. Filter retrieval

    Time frame: Up to 24-months

    Includes: Attempted retrieval, Successful retrieval, Failed retrieval, Percentage of retrieval success, Complications associated with filter retrieval, Reasons for failed retrieval

  6. Secondary Effectiveness Endpoint for each IVC filter brand tested only if the study is a success (i.e., both primary safety and effectiveness endpoints have been met)

    Time frame: At 12-months

    PE rate

Sponsors and collaborators

Lead sponsor

Carelon Research

Other

Collaborators

  • ALN Implants Chirurgicaux
  • Argon Medical Devices
  • B. Braun Interventional Systems, Inc
  • Bard Peripheral Vascular, Inc.
  • Cook Group Incorporated
  • Cordis US Corp.
  • Society for Vascular Surgery
  • Society of Interventional Radiology Foundation

Registry information

Acronym: PRESERVE

Important dates

Study start
2015
Primary completion
2020
Study completion
2021
First posted
Mar 6, 2015
Registry last updated
Oct 4, 2021

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.