Skip to main content
OpenTrials
Completed

NCT Number: NCT07598292

Predicting Dynamic Inspiratory Muscle Strength in COPD and Asthma Patients

This observational study evaluates whether dynamic inspiratory muscle strength can be estimated in patients with chronic obstructive pulmonary disease (COPD) and asthma using simple clinical and performance-based measurements. Dynamic inspiratory muscle strength was assessed using the S-Index, which reflects the pressure generated during a fast and forceful inspiration while airflow is maintained.

The study included adult male patients diagnosed with COPD or asthma. Participants completed respiratory muscle strength assessment, pulmonary function testing, body composition assessment, and a fixed-pressure inspiratory muscle performance test using a threshold loading device set at 30 cmH₂O. The number of inspiratory repetitions performed until task failure and related respiratory variables were recorded.

The main aim of the study was to develop prediction models for estimating S-Index values from accessible measures such as peak inspiratory flow, inspiratory repetition performance, spirometry parameters, and body composition variables. The study may help determine whether dynamic inspiratory muscle strength can be estimated in clinical settings where direct S-Index measurement devices are not available.

Completed

Looking for future studies?

Notify Me

Key information

About this study

Dynamic inspiratory muscle strength provides important information about the functional capacity of the inspiratory muscles. In patients with chronic respiratory diseases such as COPD and asthma, respiratory muscle function may be affected by airflow limitation, altered ventilatory mechanics, dyspnea, and reduced exercise tolerance. Although maximal inspiratory pressure is commonly used to assess respiratory muscle strength, it mainly reflects static pressure-generating capacity. The S-Index is a dynamic measure obtained during a rapid and forceful inspiratory maneuver and may provide additional information about inspiratory muscle performance under flow-dependent conditions.

This study was designed as an observational, cross-sectional predictive modeling study. Adult male patients with a clinical diagnosis of COPD or asthma were prospectively recruited from clinical units of Çorum Erol Olçok Training and Research Hospital, Hitit University, Türkiye. All participants provided informed consent before participation. The study was approved by the Hitit University Non-Interventional Research Ethics Committee.

Participants attended a familiarization session before the measurement day. During this session, the study procedures were explained, the measurement techniques were demonstrated, and participants were informed about behaviors to avoid before testing. On the measurement day, demographic information was recorded, and participants underwent dynamic inspiratory muscle strength assessment, body composition assessment, pulmonary function testing, and a fixed-pressure inspiratory muscle performance test.

The S-Index was measured using the POWERbreathe K5 device in single-breath test mode. Participants were instructed to exhale fully to residual volume and then perform the fastest and strongest possible inspiration through the device until the lungs were completely filled. Multiple trials were performed, and the highest S-Index value was used for analysis.

Pulmonary function testing was performed using standardized spirometry procedures. Forced vital capacity, forced expiratory volume in one second, the FEV1/FVC ratio, peak expiratory flow, peak inspiratory flow rate, and inspiratory volume were recorded. Body composition variables, including body weight, body mass index, fat-free mass, fat mass, and body fat percentage, were assessed using multi-frequency bioelectrical impedance analysis.

Inspiratory muscle performance was evaluated using a fixed-pressure inspiratory muscle loading task with the POWERbreathe Classic Light Resistance device set at 30 cmH₂O. Participants performed continuous inspiratory efforts through the device until task failure. The total number of valid inspiratory repetitions and the time to task failure were recorded. Task failure was defined as inability to maintain rhythmic breathing, marked reduction in inspiratory effort, technical errors, or voluntary termination due to inability to continue.

Safety was monitored throughout the testing procedures by healthcare professionals and researchers experienced in respiratory physiology and exercise testing. Testing was stopped if clinically relevant symptoms occurred, including severe dyspnea, dizziness, chest pain, wheezing, chest tightness, coughing attacks, or inability to maintain proper technique. No adverse clinical events requiring medical intervention were reported during the study.

The primary purpose of the analysis was to develop statistical and machine learning-based prediction models for estimating S-Index values. Predictor variables included demographic characteristics, body composition variables, spirometry parameters, peak inspiratory flow, inspiratory volume, number of inspiratory repetitions, and time to task failure. Regression-based models were developed and evaluated using standard prediction performance metrics, including mean squared error, mean absolute error, root mean squared error, and the coefficient of determination.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Being 18 years of age or older
  • Having a clinical diagnosis of chronic obstructive pulmonary disease or asthma
  • Being able to perform fixed-pressure inspiratory muscle loading and S-Index measurements in accordance with the instructions and with correct technique
  • Having experienced no additional clinical condition within the previous 12 weeks, apart from the existing chronic respiratory disease, that could acutely affect respiratory function
  • Having signed the informed consent form approved by the ethics committee

Exclusion criteria

  • Smoking
  • Inability to perform fixed-pressure inspiratory muscle loading or dynamic respiratory muscle strength assessment according to the technical requirements of the measurement protocols
  • Inability to obtain reliable data due to insufficient coordination, motivation, or volitional effort
  • Presence of a musculoskeletal injury or surgical history affecting the diaphragm, thorax, spine, or abdominal region that could significantly impair respiratory mechanics
  • Presence of neurological conditions that may affect respiratory muscle function, such as neuromuscular diseases, peripheral nerve damage, or central nervous system disorders

Treatment and study plan

Primary outcomes

  1. Dynamic Inspiratory Muscle Strength Assessed by S-Index

    Time frame: Day 1, during the single assessment visit

    Dynamic inspiratory muscle strength was assessed using the S-Index measured with the POWERbreathe K5 device in single-breath test mode. Participants performed maximal and rapid inspiratory efforts after full expiration to residual volume. The highest S-Index value obtained from repeated maximal inspiratory efforts was recorded in cmH₂O.

Secondary outcomes

  1. Number of Inspiratory Repetitions to Task Failure

    Time frame: Day 1, during the single assessment visit

    Inspiratory muscle performance was evaluated using a fixed-pressure inspiratory muscle loading task with the POWERbreathe Classic Light Resistance device set at 30 cmH₂O. The total number of valid inspiratory repetitions completed until task failure was recorded as a count.

  2. Time to Task Failure During Fixed-Pressure Inspiratory Loading

    Time frame: Day 1, during the single assessment visit

    The duration of the fixed-pressure inspiratory muscle loading task was measured using a stopwatch. Time to task failure was recorded in seconds from the start of the test until the participant could no longer continue with proper technique or voluntarily stopped.

  3. Forced Vital Capacity

    Time frame: Day 1, during the single assessment visit

    Forced vital capacity was assessed using standardized spirometry procedures and recorded in liters.

  4. Forced Expiratory Volume in One Second

    Time frame: Day 1, during the single assessment visit

    Forced expiratory volume in one second was assessed using standardized spirometry procedures and recorded in liters.

  5. FEV1/FVC Ratio

    Time frame: Day 1, during the single assessment visit.

    The ratio of forced expiratory volume in one second to forced vital capacity was calculated from standardized spirometry measurements and recorded as a percentage.

  6. Peak Expiratory Flow

    Time frame: Day 1, during the single assessment visit.

    Peak expiratory flow was obtained from standardized spirometry testing and recorded in liters per second.

  7. Inspiratory Volume

    Time frame: Day 1, during the single assessment visit.

    Inspiratory volume was obtained during pulmonary function testing and recorded in liters.

  8. Secondary Outcome Measure 7

    Time frame: Day 1, during the single assessment visit.

    Peak inspiratory flow rate was obtained from the inspiratory phase of the standardized flow-volume curve and recorded in liters per second.

Sponsors and collaborators

Lead sponsor

Hitit University

Other

Registry information

Official study title

Prediction Models for Dynamic Respiratory Muscle Strength in COPD and Asthma Patients Based on Constant-Pressure Inspiratory Muscle Performance

Acronym: DIMS-PRED

Important dates

Study start
2026
Primary completion
2026
Study completion
2026
First posted
May 20, 2026
Registry last updated
May 20, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.