Skip to main content
OpenTrials
Completed

NCT Number: NCT07499726

Precision of Patient Specific 3D Printed Occlusal Stent, Surgical Guide, and Patient Specific Titanium Plates in Management of Mandibular Fracture (Case Series)

This study evaluates the accuracy of preoperative fully computerized occlusal stents, surgical guide, and patient-specific titanium plates in guided mandibular fracture reduction and fixation. The research question is: Does the use of patient-specific three-dimensional (3D) printed occlusal stents, surgical guides, and titanium plates accurately reduce mandibular fractures regarding guided fracture reduction, fixation, and occlusion? Mandibular fractures are among the most common maxillofacial fractures observed in the emergency room. The evaluation, diagnosis, and management of these fractures remain challenging despite improved imaging technology and fixation techniques. Depending on the type and location of the fractures, various open and closed surgical reduction techniques can be utilized. There are several critical and inherent limitations to the current standard approach of mandibular fracture reduction and fixation.

The anatomical term "body fractures" is used in the present study. It refers to the tooth-bearing area of the mandible including symphyseal, parasymphyseal, and body fractures. Anatomically, the mandible consists of a curved horizontal portion (the body) with the alveolar process on top, and two perpendicular portions (the rami), which unite with the ends of the body nearly at right angles.

Conventionally, surgical plates are mass-produced with universal configurations that must be manually bent to match individual bone anatomy. The plate bending procedure can be time-consuming and technically demanding, especially for inexperienced surgeons. In complex cases, surgical plates may need to be bent repeatedly, which induces internal stress concentration. The stressed plates may suffer from fatigue under in vivo masticatory loading, resulting in complications including plate fracture, corrosion, screw loosening, and bone resorption.

Three-dimensional (3D) printing involves additive manufacturing techniques used to build structures layer by layer. This technology has been adapted to a wide range of surgical applications. It has been used to print patient-specific anatomic models, implants, prosthetics, external fixators, splints, surgical instrumentation, and surgical cutting guides. The utility of this technology in surgery explains its rapid adoption.

There are no comparators in this study because it is a case series. Objectives: This study aims to evaluate the accuracy of preoperative fully computerized occlusal stents, surgical guides, and patient-specific titanium plates in guided mandibular fracture reduction and fixation.

Primary Objectives:

* To achieve anatomical reduction with accurate post-operative occlusion * To reduce intra-operative time with subsequent reduction in post-operative pain and edema Hypothesis: We hypothesize that preoperative fully computerized occlusal stents, surgical guides, and patient-specific titanium plates are an accurate method for mandibular fracture reduction and fixation.

Trial Design: This is a prospective case series study conducted on adult patients with mandibular fractures.

PIO:

* Population: Patients with mandibular fracture requiring open reduction internal fixation (ORIF) * Intervention: Preoperative fully computerized occlusal stents, surgical guides, and patient-specific titanium plates * Outcome: Accuracy of reduction and occlusion

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–65 year

Sex eligibility

All sexes

Study type

Observational

Primary location

Faculty of Dentistry, Cairo University

Cairo, Egypt

Who can participate

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Age 18 to 65 years
  • Male or female patients
  • Isolated mandibular fractures requiring open reduction and internal fixation (ORIF)

Exclusion criteria

  • Severe cardiovascular, respiratory, or other systemic conditions presenting risk for anesthesia
  • Head and neck radiation therapy within the past year
  • Uncontrolled diabetes (glycated hemoglobin HbA1c > 8%)
  • Pregnancy or lactation

Treatment and study plan

Patient-Specific 3D Printed Occlusal Stent, Surgical Guide, and Titanium Plates

Procedure

Patients underwent preoperative virtual surgical planning using Mimics software. Patient-specific three-dimensional (3D) printed occlusal stents, surgical guides, and titanium plates (2.0 mm thickness, Grade 4 titanium) were fabricated. Surgical procedure included intraoral or extraoral approach as indicated, fracture reduction using custom guides, fixation with patient-specific plates, and standard postoperative care including antibiotics and soft diet for 4-6 weeks. Postoperative computed tomography (CT) scan was obtained at 4 weeks for accuracy assessment via superimposition analysis.

Primary outcomes

  1. Dimensional Accuracy of Mandibular Fracture Reduction

    Time frame: 4 weeks post-operative

    Absolute error between planned (virtual surgical planning) and post-operative measurements across 12 standardized mandibular measurements (Lateral Intercondylar Length, Medial Intercondylar Length, Bicoronoid Length, Bigonial Width, Bimental Length, Maximum Mandibular Length Right, Maximum Mandibular Length Left, Intercanine Length, Maximum Ramus Height Right, Maximum Ramus Height Left, Mandibular Angle Right, Mandibular Angle Left) assessed via computed tomography (CT) superimposition analysis at 4 weeks post-operative.

Secondary outcomes

  1. Clinical Acceptability Rate

    Time frame: 4 weeks post-operative

    Proportion of measurements achieving absolute error < 2.0 mm (clinically acceptable threshold) and < 1.0 mm (excellent accuracy threshold) based on computed tomography (CT) superimposition analysis.

  2. Rotational Movement Pattern

    Time frame: 4 weeks post-operative

    Identification and quantification of rotational movement characterized by anterior widening (intercanine length change) and posterior narrowing (bicoronoid and bigonial width changes) measured by Rotational Divergence Index (RDI) from computed tomography (CT) superimposition analysis.

Sponsors and collaborators

Lead sponsor

Cairo University

Other

Registry information

Important dates

Study start
2024
Primary completion
2025
Study completion
2025
First posted
Mar 30, 2026
Registry last updated
Apr 3, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.