Minuteman G5 Device
DeviceThe Minuteman G5 MIS Fusion Plate consists of spinous process plates and surgical instruments. Implants are made of Titanium alloy
NCT Number: NCT06355791
This is a prospective, multi-center open-label single arm post-market study where the purpose is to evaluate the effectiveness and safety of the market approved Spinal Simplicity Minuteman G5 MIS Fusion Plate and bone graft material in patients with degenerative conditions of the lumbar spine resulting in chronic low back pain with lower extremity symptoms and concurrent neurogenic claudication. The indication for the device under study is degenerative conditions of the lumbar spine resulting in back pain with lower extremity symptoms and neurogenic claudication.
Interested in participating?
Request Info18 year and older
All sexes
Interventional
Not applicable
Vista Clinical Research, Newnan, Georgia, United States
Up to 150 subjects will be enrolled and treated at up to 20 study sites. Qualified subjects will be enrolled and treated with the Minuteman G5 Device. Subjects will be seen at 1-, 3-, 6- and 12-months following study treatment.
Key outcome assessments will include gait and balance testing performed using BioMech Lab sensor technology to capture and deliver three-dimensional patient motion data to a mobile device that instantly analyzes, distills, and quantifies the information. Patient reported outcome measures will also be collected to evaluate pain, quality of life and satisfaction. During the primary assessment at 12-months post-treatment subject will be offered a computerized topography (CT) scan to evaluate spinal fusion.
After completion of the Month 12 visit all subjects will be asked to complete annual visits through 5 years, which include collection of PROMs, safety review, and can be completed in person or remote.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
A subject must MEET ALL of the following inclusion criteria:
Exclusion criteria
A subject must NOT MEET ANY of the following exclusion criteria:
The Minuteman G5 MIS Fusion Plate consists of spinous process plates and surgical instruments. Implants are made of Titanium alloy
Time frame: Baseline and 1-, 3-, 6- and 12-months post implantation; annually out to five years.
Overall pain, as well as back pain when standing/walking and leg pain when standing will be assessed using a numeric rating scale (NRS). The NRS is a pain screening tool, commonly used to assess pain severity at that moment in time using a 0-10 scale, with zero meaning "no pain" and 10 meaning "the worst pain imaginable.
Time frame: Baseline and 1-, 3-, 6- and 12-months post implantation; annually out to five years.
ODI is a self-reported questionnaire widely used to track changes in a patient's condition over time and evaluate the effectiveness of treatments for low back pain. The ODI consists of 10 sections, each addressing a specific aspect of daily functioning. A higher score indicates greater disability. The final score/index ranges from 0-100 scale. A score of 0-20 reflects minimal disability, 21-40 moderate disability, 41-60 severe disability, 61-80 crippled, and 81-100 bed-bound.
Time frame: Baseline and 1-, 3-, 6- and 12-months post implantation; annually out to five years.
PROMIS-29 c2.0 is a set of standardized questions that measures 29 items across 7 domains of physical and mental health. PROMIS-29 profile assesses pain intensity using a single 0-10 numeric rating scale, with zero meaning "no pain" and 10 meaning "the worst pain imaginable. And seven health domains (physical function, fatigue, pain interference, depressive symptoms, anxiety, ability to participate in social roles and activities, and sleep disturbance) using four items per domain. Each domain is scored on T-Score Scale ranging between 22.9- 81.6 with a mean of 50 and a standard deviation of 10.
Time frame: Baseline and 1-, 3- and 12-months post implantation.
A Primary Objective of this study is to collect real-world functional outcomes assessment of motion following treatment with the market-released Spinal Simplicity Minuteman G5 Device using BioMech Lab equipment to record gait and balance. The BioMech Lab motion analytics system will assess gait and balance via sensors placed before physical testing.
Time frame: Baseline and 1-, 3- 6- and 12-months post implantation; annually out to five years.
The ZCQ Symptom Severity, Physical Function and Subject Satisfaction allows subjects to rate their symptoms, function or satisfaction on a scale based on their experience over the past week.
Symptom Severity domain evaluates the intensity of symptoms such as pain and numbness. It comprises seven items, each rated on a scale from 1 to 5. Overall symptom score ranges from 7-49; with higher scores indicating more severe symptoms.
Physical Function domain assesses the impact of symptoms on daily activities. It includes five items, scored on a 1 to 4 scale. Overall symptom score ranges from 5-20; where higher scores denote greater functional impairment.
Subject Satisfaction domain measures patient satisfaction with treatment outcomes. It consists of six items, each rated from 1 to 4, with higher scores reflecting greater dissatisfaction. Overall Satisfaction ranges from 6-24: where higher scores denote greater dissatisfaction.
Time frame: Collected at 12 months post implantation.
The secondary objective is to assess spinal fusion at 12 months post-operative using a Fusion Assessment Scale provided by Spinal Simplicity based on review of Lumbar CT Scan.
Contact information is provided by the study sponsor or research team.
Adam Rogers
CONTACT
Echo Cundiff
CONTACT
Spinal Simplicity LLC
Industry
The Stability Study: Open-Label, Multi-Center, Post-Market Study of Functional Motion Outcomes In Subjects Treated With the Spinal Simplicity Minuteman G5 Fusion Plate
Acronym: STABILITY
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02250248
Bone Diseases, Degenerative Conditions of the Lumbar Spine
Barro Preto, Minas Gerais, Brazil
View Trial DetailsNCT03754972
Bone Diseases, Disease
Amsterdam, Netherlands
View Trial DetailsNCT05345249
Bone Diseases, Fusion of Spine
Ubbergen, Gelderland, Netherlands
View Trial DetailsNCT01455805
Bone Diseases, Degenerative Disc Disease
Taunton, Somerset, United Kingdom
View Trial Details