Skip to main content
OpenTrials
Recruiting

NCT Number: NCT07651735

Post-Market Clinical Follow-Up (PMCF) Study Evaluating the Safety and Efficacy of Tıpmed™ Primary Hip Prosthesis System

This is a multicenter, prospective, observational, post-market clinical follow-up (PMCF) study designed to evaluate the safety and clinical performance of the Tipmed™ Primary Hip Prosthesis System in adult subjects undergoing primary hip arthroplasty. The study aims to gather real-world clinical evidence on the 24-month post-operative safety profile, potential complications, and functional outcomes of the device during routine clinical practice.

Recruiting

Interested in participating?

Request Info

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Republic of Turkey Ministry of Health, Balıkesir Provincial Health Directorate, Atatürk City Hospital, Balıkesir, Turkey (Türkiye)

Loading trial locations.

About this study

This prospective, observational, PMCF study evaluates the short-to-medium-term safety and efficacy data of the Tipmed™ Primary Hip Prosthesis System in patients undergoing primary hip arthroplasty (total or partial) across 4 clinical centers in Turkey. A total of 101 eligible participants will be enrolled in accordance with the pre-defined inclusion and exclusion criteria. Pre-operative demographic details, medical history, and surgical parameters will be captured retrospectively from patient medical charts. Following the baseline surgical procedure, subjects will undergo a 24-month clinical follow-up period consisting of 6 routine post-operative assessment windows: at 6 weeks, 3 months, 6 months, 12 months, 18 months, and 24 months. At each longitudinal visit, investigators will complete a study-specific Case Report Form (CRF) to document objective clinical indicators. Clinical performance and joint functionality will be quantitatively monitored utilizing the Harris Hip Score (HHS). Safety endpoints will be continuously evaluated by identifying, classifying, and reporting any adverse events (AEs), serious adverse events (SAEs), implant-related complications (such as dislocation, aseptic loosening, or infection), and hardware deficiencies. Radiological findings (implant orientation, migration, osteointegration) and laboratory indicators (such as C-Reactive Protein and Sedimentation Rate) will be documented when available as part of standard medical surveillance.

Demographic characteristics, clinical parameters, and efficacy/safety outcomes will be summarized using descriptive statistics. Stratified analyses will be conducted based on the specific type of primary surgical intervention. Separate subgroup analyses will be executed for study participants who undergo partial hip arthroplasty (hemiarthroplasty) to isolate and evaluate their outcomes independently from the patients treated with total hip arthroplasty. Categorical variables across these subgroups will be compared using the Chi-square test or Fisher's exact test, as appropriate.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Individuals aged 18 years and older,
  • Male or female participants,
  • Subjects who have undergone Primary Hip Arthroplasty (either total or partial) for any indication,
  • Subjects in whose surgical procedure the Tipmed™ Primary Hip Prosthesis System components were utilized.
  • Subjects who are not legally restricted (e.g., military personnel, convicts, or individuals under legal guardianship).
  • Subjects who have voluntarily signed the written Informed Consent Form (ICF).

Exclusion criteria

  • Subjects currently participating in any other interventional clinical trial.

Treatment and study plan

Tipmed™ Primary Hip Prosthesis System

Device

Post-market utilization of the commercially available Tipmed™ Primary Hip Prosthesis System during routine orthopedic care. Device components include various configurations such as cemented or uncemented stems (anatomic or square cross-section), acetabular cups, bipolar cups, and titanium metal shells fitted according to standard clinical routine and patient anatomy. No investigational or non-routine interventions are performed as part of this observational registry.

Primary outcomes

  1. Functional Joint Performance via Harris Hip Score (HHS) at 24 Months

    Time frame: 24 months post-operatively.

    The proportion of participants achieving "Excellent" (≥ 90 points) or "Good" (80-89 points) clinical performance based on the Harris Hip Score (HHS) will be evaluated. The HHS is a clinician-administered tool that quantitatively scores hip function across domains including pain, function, functional activities, absence of deformity, and range of motion (ROM), with a total score ranging from 0 (worst possible outcome) to 100 (best possible outcome).

  2. Incidence of Adverse Events (AEs) and Serious Adverse Events (SAEs)

    Time frame: From the signing of informed consent up to 24 months post-operatively.

    Continuous monitoring, documentation, and cumulative tracking of the incidence of all adverse events (AEs) and serious adverse events (SAEs) occurring throughout the study period, regardless of their causal relationship to the investigational medical device or surgical procedure. Events will be systematically classified by severity (mild, moderate, severe), outcome, and causality pattern.

  3. Incidence of Clinical Complications

    Time frame: From the time of signing the informed consent form up to 24 months post-operatively.

    Evaluation of the rate, frequency, and types of all complications recorded throughout the study period. This includes intraoperative complications captured retrospectively from surgical medical records (such as femoral or acetabular fractures, vascular injuries, and nerve lesions) as well as longitudinal complications documented during the follow-up phase (such as joint dislocation, aseptic loosening, implant breakage, or deep and superficial surgical site infections) associated with the routine clinical utilization of the Tipmed™ Primary Hip Prosthesis System.

Secondary outcomes

  1. Longitudinal Changes in Hip Functioning via Harris Hip Score (HHS)

    Time frame: Retrospective pre-operative baseline, and prospective assessments at 6 weeks, 3, 6, 12, 18, and 24 months post-operatively.

    Periodic monitoring of absolute HHS tracking metrics and category shifts to determine the trajectory of functional recovery over time. The total HHS ranges from 0 (worst possible outcome) to 100 (best possible outcome) and is categorized as follows: Excellent (90-100); Good (80-89); Fair (70-79); Poor (60-69); and Very Poor (<60). Transition tables will be generated utilizing these classifications to map longitudinal shifts from the retrospectively captured pre-operative baseline value (extracted from patient medical charts) across all prospective post-operative follow-up intervals.

Study contacts

Contact information is provided by the study sponsor or research team.

Yasemin Önel, Sponsor Rep

CONTACT

[email protected]

+90 232 479 33 22

Sponsors and collaborators

Lead sponsor

TIPMED Medical Device Manufacturing Ltd. Co.

Industry

Registry information

Official study title

A Multicenter, Prospective, Observational, Post-Market Clinical Follow-Up (PMCF) Study Evaluating the Safety and Efficacy of Tıpmed™ Primary Hip Prosthesis System

Important dates

Study start
2024
Primary completion
2028
Study completion
2029
First posted
Jun 16, 2026
Registry last updated
Jun 16, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.